Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KESAR PETROLEUM INC T717 W EIGHTH ST, STOCKTON March 15, 2022 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 HSC 25284; CCR 2711(d) Failure to obtain a permit to operate from the EHD including but not limited to unpaid <br /> permit fees. <br /> OBSERVATION:A change of owner took place on November 12, 2021.The 2022 UST Annual permit fees were not <br /> paid until February 23, 2022.A CERS submittal was first made on February 25, 2022.The 2022 operating permit <br /> was issued effective 2/25/2022. <br /> REGULATION GUIDANCE: No person may own or operate an UST unless a permit for its operation has been <br /> issued by the local agency to the owner or operator of the UST system.The permit application must be submitted to <br /> the California Environmental Reporting System (CERS)within 30 days from the date of change of ownership. <br /> CORRECTIVE ACTION: Ensure that all future operating permits are obtained by January 1 St. <br /> This is a Class II violation. <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST. <br /> OBSERVATION: UST Tank Information forms are not current in the California Environmental Reporting System <br /> (CERS). Tank form incorrectly states the site is using fill tube shut-off valve (flappers)as the overfill prevention <br /> method. No flappers were observed. <br /> REGULATION GUIDANCE:Any change of information must be updated in CERS within 30 days of the changes. <br /> CORRECTIVE ACTION: Immediately log into CERS, update the required information, and submit for review by the <br /> EHD. <br /> ----------------------------------------------------------- <br /> OBSERVATION: The UST Facility Operating Permit Application contains an incorrect California Department of Tax <br /> and Fee Administration (CDTFA) Underground Storage Tank Account Number.The CDTFA number provided on <br /> site and verified as valid for this facility is 44043937. <br /> REGULATION GUIDANCE: The application for a permit to operate an underground storage tank shall include the <br /> CDTFA registration number issued to the owner of the tank, in accordance with HSC 25286. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS), update the <br /> required information, and submit for review by the EHD. <br /> This is a minor violation. <br /> FA0015274 PR0522448 SCO01 03/15/2022 <br /> EHD 23-01 Rev.9/16/2020 Page 4 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />