My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WAGNER
>
200
>
2200 - Hazardous Waste Program
>
PR0513594
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2022 4:23:59 PM
Creation date
2/14/2022 12:48:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0513594
PE
2229
FACILITY_ID
FA0007670
FACILITY_NAME
SPX COOLING TECHNOLOGIES INC
STREET_NUMBER
200
Direction
N
STREET_NAME
WAGNER
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
15902010
CURRENT_STATUS
01
SITE_LOCATION
200 N WAGNER AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
361
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN ,dDAQ U I N Environmental Health Department <br /> C 0 u T AMENDED <br /> 3/28/2022 <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SPX COOLING TECHNOLOGIES INC 200 N WAGNER AVE, STOCKTON February 18, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 708 CCR 66273.35 Universal Waste Handler stored waste onsite greater than one year or storage time unknown. <br /> OBSERVATION: The facility could not demonstrate that universal waste has been stored on site for no longer than <br /> one year. The following UW was stored on-site: one mercury lamp and one fluorescent tube lamp. <br /> REGULATION GUIDANCE: Title 22 California Code of Regulations section 66273.35 Accumulation Time Limits <br /> CORRECTIVE ACTION: Since it could not be demonstrated how long this UW was stored on site, immediately <br /> dispose of this UW in accordance with Title 22 California Code of Regulations. Provide a corrective action <br /> statement, the disposal record and supporting documentation to the San Joaquin County Environmental Health <br /> Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection report was provided to the facility operator on the day of inspection. After receiving more <br /> information about the facility on 3-18-22 from SPX, the report was amended on 3-28-22 removing violations <br /> 501, 502 and 507 and replaces the initial report. All violations on this report have been resolved. <br /> Waste streams generated by this facility: hazardous waste solids cleaned from the stormwater collection system, <br /> filter cake hazardous waste from the water treatment system filter press, used oil, universal waste lamps. <br /> The site has generated the following amounts of hazardous waste: zero tons in 2021, 14 tons in 2020, 72 tons in <br /> 2019 and 30 tons so far in 2022. <br /> Four 20 cubic yard bins of hazardous waste solids, labeled with an accumulation date of approximately February <br /> 8, 2022, were observed south of the water treatment building. <br /> This facility is exempt from a CUPA Tiered hazardous waste treatment permit per California Health &Safety <br /> Code 25358.9. This is a groundwater remediation site overseen by DTSC and the Water Board. It's listed in <br /> Envirostor under Marley Cooling Tower, 150 N Sinclair. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209)468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: March 28, 2022 Inspector: Inspector Phone: <br /> Printed Name and Title: GARRETT BACKUS, Lead Senior REHS (209)468-2986 <br /> Emailed to Guy Graening, PE, <br /> FA0007670 PR0513594 SCO01 02/18/2022 <br /> EHD 22-02 Rev.12/06/2021 Page 9 of 9 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.