My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SHAW
>
1113
>
1900 - Hazardous Materials Program
>
PR0521219
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2022 12:40:36 PM
Creation date
2/17/2022 9:21:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0521219
PE
1921
FACILITY_ID
FA0003565
FACILITY_NAME
Sweeping Corporation of America
STREET_NUMBER
1113
STREET_NAME
SHAW
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
14327042
CURRENT_STATUS
01
SITE_LOCATION
1113 SHAW RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of hazardous materials violations that have not been <br /> addressed for Sweeping Corporation of America as of September 19, 2022. <br /> Open violations from February 16, 2022 inspection <br /> Violation #5 - Failed to electronically submit hazardous materials inventory for all reportable materials on <br /> site. <br /> OBSERVATION The Hazardous Materials Inventory forms for the motor oil and hydraulic were not accurate. <br /> 1 . Motor oil — the storage pressure was wrongly reported as above ambient vs. ambient. <br /> 2. Hydraulic oil — the storage pressure was wrongly reported as above ambient vs. ambient. <br /> REGULATION GUIDANCE: The Hazardous materials inventory information must be current and submitted as part <br /> of the business plan . <br /> CORRECTIVE ACTIONS: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers. calepa.ca. gov/, enter the correct or updated information , and submit to the EHD for approval. <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation #6 - Failed to electronically submit a site map with all required content. <br /> OBSERVATION The site map uploaded at the time of inspection is not complete. The site map does not <br /> show/address the following required elements: <br /> 1 . Loading areas. <br /> 2. Internal roads. <br /> 3. Emergency response equipment (spill control) . <br /> 4. Emergency shutoffs. <br /> 5. The symbol used to identify compressed gasses does not differentiate between the type of gasses, acetylene , <br /> propane, and oxygen. <br /> REGULATION GUIDANCE: A site map shall contain a north orientation , loading areas, internal roads, adjacent <br /> streets, storm and sewer drains, access and exit points, emergency shutoffs, evacuation staging areas, hazardous <br /> material handling and storage areas, and emergency response equipment. <br /> If a site map element is not applicable for your facility then list it on the map and label as "NA". <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers. calepa.ca. gov/, upload the correct or updated information, and submit to the EHD for approval. <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.