REVISIONSDateNo.DescriptionJob No.DateDrawn byProj MgrSHEET:AKM19186CIVILSTRUCTURALLANDSCAPEARCHITECTURESURVEYINGPLANNINGATHLETICFACILITY DESIGN3428 Brookside RoadStockton,California 95219209-943-2021Fax: 209-942-0214www.siegfriedeng.comEJQ05/20/2020E1.0SHEET TITLEELECTRICALSPECIFICATIONSPROJECTSAN JOAQUINCOUNTY MICKEGROVE DELTASHELTER SEPTICREPAIRS11793 MICKE GROVE RD.LODI, CA 95240NNPE
<br />R
<br />E
<br />T
<br />DSI
<br />OROSEFSINGEIALONO. E-16370AETGER
<br />TSEXP. 6/30/22FLIFCAONREERAI DRAWD
<br />E
<br />LOJ.EUQIRORECTELCILA5445 Covey Creek CircleStockton, California 95207(209) 473-4167Edward J. Queirolo, P.E.ejqengr@sbcglobal.netwww.ejqengineering.comENGINEERINGDATE SIGNED:1.SCOPE: INSTALL FEEDER CIRCUIT TO NEW LIBERTY DUPLEX SEWAGE PUMP PANEL LABELED AND TESTED FROMMANUFACTURER (LIBERTY PUMPS). INSTALL PUMP PANEL, DEVICES, AND CONTROLS REQUIRED TO MAKE A COMPLETEOPERABLE SEWAGE SYSTEM PUMP APPLICATION PER OWNER'S REQUIREMENTS. PERFORM ANY CONTROLLERPROGRAMMING.2.WORK ONLY ON DE-ENERGIED EQUIPMENT. THE MOTOR CONTROLLER SHALL BE EQUIPPED WITH PUMP ALARMS ANDSUITABLE FOR USE WITH THE LIBERTY LSG202M 240V 1PH MOTORS.3.NOTIFY UNDERGROUND SERVICE ALERT (USA AT 1-800-642-2444) AT LEAST 48 HOURS PRIOR TO START OF WORK.DRAWINGS PROVIDED ARE DIAGRAMMATIC IN NATURE; FIELD VERIFY ALL DIMENSIONS.4.WORK SHALL CONFORM TO THE 2019 CALIFORNIA ELECTRICAL AND BUILDING CODES, LOCAL CODES AND AMENDMENTS,AND REGULATIONS. CONSULT THE LOCAL AUTHORITY HAVING JURISDICTION FOR SPECIFICS. USE ONLY NEW UL LISTEDMATERIALS.5.POWER WIRING SHALL BE COPPER USE-2/RHW-2 90°C, 600V PULLED INTO INSULATED THROAT RAINTIGHT IMC CONDUITWITH GLAND RING AND COMPRESSION STEEL FITTINGS. USE RSC WHERE UNPROTECTED AND SUBJECT TO PHYSICALDAMAGE. UNDERGROUND USE PVC-40 SLOPED AWAY FROM BUILDING AND SEALED AT BOTH ENDS TO KEEP OUT WATERAND DEBRIS.6.INSTALL GROUND ROD AT PANEL LOCATIONS MAKING GROUND BOND DIRECTLY TO PANEL GROUND BUSBAR WITHAPPROVED FITTINGS. BOND TOGETHER ALL METAL THAT MAY BECOME ENERGIZED, INCLUDING METAL WELL SLEEVESACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.7. COLOR CODE AND LABEL CONDUCTORS PER CODE AND MATCHING EXISTING. IDENTIFY AND LABEL ALL INSTALLED PANELS, CIRCUITS, MAIN CONDUIT FEEDERS, JUNCTIONS BOXES, OUTLETS, AND DISCONNECT SWITCHES WITH ENGRAVED NAMEPLATES LISTING SOURCE LOCATION AND VOLTAGE, PHASE, WARNINGS, AND WIREINFORMATION.8. EXISTING EQUIPMENT NOT SCHEDULED TO BE DEMOLISHED SHALL BE PROTECTED IN-PLACE; DAMAGED EQUIPMENT ORCIRCUITS SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER AND REPLACED/REPAIRED UNTIL 100%.9.CHECK FOR PROPER MOTOR PHASE ROTATION BEFORE INSTALLING PUMP INTO BASIN.10.TEST ALL NEW CIRCUITS FOR SHORTS, GROUNDS, AND PROPER SEQUENCE OF OPERATION UNTIL ALL IS 100%. AT JOB COMPLETION, AND BEFORE FINAL ACCEPTANCE BY OWNER, VERIFY THAT ALL NOTES AND REQUIREMENTS SHOWN ON PLANS AND WRITTEN SPECIFICATIONS HAVE BEEN SATISFIED.CIRCUIT BREAKER, THERM-MAG TYPE, SIZE / #POLES SHOWN40/3GROUND BUS WITH CONNECTION POINT AND WIRE SHOWNGGBELECTRICAL PANELAUTHORITY HAVING JURISDICTIONSHIELDED TWISTED PAIRUNDERWRITERS LABORATORYFEETGROUND BUSCONDUIT or CELSIUSNEUTRALCOPPERGROUND FAULT INTERRUPTERMAIN LUGS ONLYMAIN CIRCUIT BREAKERTWISTED PAIRMOUNTING HEIGHTEXISTING TO REMAINNOT TO SCALEWEATHERPROOFGROUNDTYPICALFINISHED GRADETO BE DETERMINEDMAIN SWITCHBOARDAHJSTPULftGBCNCUGFCIMLOMCBTPMH(E)NTSwpGTYPFGTBDSPLEGEND:ABBREVIATIONS:GENERAL NOTES:CEC GROUND SYSTEMPUMP MOTORGFCI DUPLEX PLUG, WATER-TIGHT, USABLEWITH COVER CLOSED, 20A, 125V, 1P2W+GWP,GFCIJRATED CODE SIZE JUNCTION BOX24"MIN.2" smooth beddingC CONTROLS (SIGNAL)P ELECT. PRIMARYCPinches77TRENCH CLEARANCE REQUIREMENTSUTILITYAS REQ'DtapeFGFG engineeredbackfill to be90% compactionwith thermal rhoof 90°C-cm/WCP7" typ.SITE TRENCH DETAILNTSAREA OF WORKWARNINGArc Flash and Shock HazardDe-energize feedercircuit(s) beforeworking onequipment(MOUNT TO PANEL DEAD FRONT)(E) PANEL 'A'600A, 208/120V, 3P4W, 42KAIC(E)...(E) LOADS...1SHEET KEYED NOTESPROVIDE PANEL 'A' WITH 60/2 240VAC FEEDER BREAKER 42KAIC AND WIRE.INSTALL GROUND ROD AT PANEL 'SP'. BOND EQUIPMENT AND RACK TO PANEL GROUND BAR.INSTALLED PUMP PANEL 'SP' ONTO UNISTRUT RACK. INSTALL GFI DUPEX RECEPTACLE (USABLE WITH COVER CLOSED). SET OVERLOADS. INSTALL FLOAT SWITCHES. PROGRAM PUMP PANELCONTROLLER AS REQUIRED TO FACILITATE LEAD-LAG PUMP CONTROL AND ALARM MONITORING. INSTRUCT OWNER IN OPERATION AND MAINTENANCE. TYPE 4X OUTDOOR 12"H x 10"W x 6"D,APPROXIMATELY 40LBS.CONTRACTOR TO PROVIDE AND INSTALL 100A MAIN TERMINAL BLOCK, 20A 125V DUPLEX GFCI RECEPTACLE AND BOX, AND OTM20 CONTROL FUSE, BLOCK, AND PULLER ONTO BACKPAN.CONNECT 120VAC CONTROL POWER AND CONNECT VENDOR SUPPLIED MOTOR CABLES TO PANEL CONTACTORS.PICKUP (E) BOX 2"C FROM PANEL 'A' AND EXTEND FEEDER CIRCUIT TO PUMP PANEL LOCATION. RUN 1" SPARE WITH OWNER APPROVAL.XRAY AND MARK U.G. CONDUIT ROUTING.(N)60/2(N) PUMP PANEL 'SP'GBNNBG2MODELHPVOLTPHFLATYPENOTESMCAMOCPLSG202M2208-230115MANUALLIBERTY SUBMERSIBLE MOTORS WITH OVERLOAD PROTECTION TO BECONNECTED TO LIBERTY AE24H=3 PUMP PANEL. MOTOR POWER CABLESSUPPLIED FROM MANUFACTURER.1830ELECTRICAL / MECHANICAL EQUIPMENT (SEE MANUFACTURER'S INSTALLATION INSTRUCTIONS)(N)2"C, 3-2/0, #6G1"C SPARE400'GBNNBGGND4X DEAD-FRONT PUMP PANEL 'SP'CB1C1LINEGFCIPAN1"=20'ELECTRICAL SITE PLANHORN32"C, 3-2/0, #6G1"C SPARE1. SEQUENCE OF OPERATION: START OR STOP MANUALLY USING LOCAL HOA; AUTO START WITH INPUT TO CONTROLS; RESET ALARM WITH EXTERIOR ALARM TEST/NORMAL/SILENCE SWITCH. FLOATSWITCHES USED AS NEEDED FOR CONTROL.2. INSPECTION &APPROVALS: INSPECT AND TEST PUMP PANEL BEFORE INSTALLATION FOR PROPER OPERATION AND VERIFY DEVICE MOUNTING SCREW AND WIRE TERMINAL TORQUE TIGHTNESS(SEE SHEET E2). VERIFY PROPER UL LABELING AND INTEGRITY OF DUPLEX MOTOR DISCONNECTS AND CONTACTORS AND CONTROL DEVICES. PANEL MUST BE UL LABELED AS A COMPLETEASSEMBLY. SET DEVICES, INCLUDING MOTOR OVERLOADS, PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.3. PANEL LABELING: SHALL BE MACHINE MADE AND PERMANENTLY AFFIXED. INCLUDING UL LABELS, MANUFACTURER SPECIFICATIONS LABELS, WARNING LABELS, TERMINAL BLOCK IDENTIFICATIONLABELS, WIRE TAGS, AND ANY LABELS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. LABELS SHALL BE OF SUCH COLOR, SIZE, AND CONTENT AS REQUIRED BY CODE AND TO MAKE PLAINLYVISIBLE. ANY SPECIAL PRODUCT INFORMATION REQUIRING ADJUSTMENT OR CHANGES NOT READILY APPARENT ON THE DEVICE SHALL BE LABELED TO DESCRIBE ADJUSTMENT PROCEDURE ANDSETTING. ENCLOSURE FRONT DOOR LABELS ARE REQUIRED TO DESCRIBE THE EQUIPMENT: AFFIX 1.5 X 4 PHENOLIC NAMEPLATE W/HOLES, SATIN FINISH, & BEVELED RED-WHITE-RED ON FRONTCOVERS TO IDENTIFY EQUIPMENT - INCLUDE PANEL NAME, VOLTAGE, AMPS, WIRES, WARNINGS, SOURCE OF POWER LOCATION, ETC. AND PERMANENTLY FASTEN TO DOOR WITH PERMANENTADHESIVE OR STAINLESS TAPPED SCREWS.4. ENCLOSURE: TYPE-4X OUTDOOR FIBERGLASS 12"H x 10"W x 6"D WITH LOCKABLE GASKETED DOOR.5. COMPONENTS AND WIRE: INSTALL POWER TERMINAL BLOCK AND CONTROL FUSE MOUNTED ONTO BACKPAN WITH FLAT WASHER, LOCKING WASHER, AND TAPPED STAINLESS MACHINE SCREWSPROPERLY TORQUED (SEE SHEET E2.0). INSTALL GFCI OUTLET AND CONNECT 120VAC CONTROL POWER. ALL COMPONENTS AND WIRE SHALL BE UL MARKED. WIRE AND TERMINAL BLOCK LABELSMACHINE MADE. UNDERGROUND USE USE-2/RHW-2 COPPER STRANDED 90°C RATED DIRECT BURIAL RATED WIRE IN CONDUIT. ENCLOSURE AND STARTER COMPONENTS SHALL BE MOUNTED WITHFLAT AND LOCK WASHERS WITH TAPPED STAINLESS SCREWS TO PREVENT LOOSENING CAUSED BY ENVIRONMENTAL VIBRATIONS. TIGHTEN ALL COMPONENT CONNECTIONS TO MANUFACTURER'STORQUE SPECIFICATIONS PRIOR TO ENERGIZING. FUSE PULLER SHALL BE PROVIDED FOR EACH FUSE. FOR ALARM, TOP RED FLASHING LED BEACON WITH FRONT DOOR HORN SHALL BE PROVIDEDFROM FACTORY WITH RESET SWITCH. ALL CONTROLS SHALL BE CLEARLY MARKED.6. WIRE TERMINATIONS: WIRE LUG TERMINATIONS SHALL BE PROPERLY RATED AND MARKED WITH APPROPRIATE WIRE TYPE, MATERIAL, AND NUMBER OF WIRES LANDED. USE RECOGNIZED GREENRING EYELET AND WELDED THREADED POST LANDING FOR ENCLOSURE GROUND (GROUND POST SHALL BE CLEAN AND UN-PAINTED TO MAKE DIRECT METALLIC CONTACT WITH EYELET). TIGHTENOR CRIMP ALL WIRE CONNECTIONS WITH APPROVED TOOL AND ACCORDING TO THE LUG MANUFACTURER'S TORQUE VALUE PRIOR TO ENERGIZING. WIRE TERMINALS ARE ASSUMED RATED FOR ASINGLE WIRE UNLESS OTHERWISE LISTED OR MARKED. NO SOLDER ALLOWED.7. DISCONNECT DEVICE: UL LISTED CIRCUIT BREAKER BY MANUFACTURER INTEGRAL TO PUMP PANEL. ADJUST TRIP IF NECESSARY TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.8. FVNR MOTOR STARTER: PER MOTOR NAMEPLATE INCLUDING, HORSEPOWER, PHASE, VOLTS, AND TYPE.9. OPERATORS: CONTROLLER MOUNTED INSIDE ENCLOSURE.10. AUXILIARY CONTACT BLOCK: MOTOR CONTACTOR AUXILIARY CONTACTS 1NO/NC RATED 5A @ 120V AC.11. TESTING: PROVIDE A VISUAL TOP-DOWN INSPECTION AND TERMINAL TORQUE TEST OF COMPLETE ENCLOSURE ASSEMBLY. VERIFY THAT EQUIPMENT MEETS REQUIREMENTS OF THE ULLABELING, RATINGS, AND INSTRUCTIONS. MAKE APPROPRIATE DISCONNECT AND OVERLOAD TRIP SETTINGS ACCORDING TO MOTOR NAMEPLATE RATINGS AND CODE REQUIREMENTS. MAKE SAFETO VERIFY THE PROPER MOTOR ROTATION. AFTER PROPER INSPECTIONS ARE COMPLETE, COORDINATE A WITNESS TEST OF THE COMPLETE SYSTEM (START, STOP, AUTO) WITH THE CONTROLSCONTRACTOR, OWNER, AND THE AUTHORITY HAVING JURISDICTION. TEST AND REPAIR SYSTEM UNTIL 100%. PROVIDE A SIGNED TEST REPORT, EQUIPMENT MANUALS, AND WARRANTIES TO OWNER.PUMP PANEL NOTES:PARTIAL ONE-LINE DIAGRAMAE24H=31DUPLEXLIBERTY PUMPS AE-SERIES DUPLEX PUMP CONTROLS 3WIRE 240/120V12x10x6 NEMA 4X; MAG MOTOR CONTACTOR HOA SWITCHES, RUN LT,3FLOAT CONTROL; MOTOR RUN BEACON/HORN ALARMS; CIRCUITBREAKER. MOUNT GFCI OUTLET TO UNISTRUT RACK.230V, 1PH21or2 HPDEAD-FRONT LOCK
<br />ING
<br /> DOORENTRY/EXIT IMC CONDUITS& SEALED THREADED HUBS2 HP6'GALV. STEEL UNISTRUTFASTEN TO PIPE WITH 3/8"U-CLAMP & LOCK NUTS.TYPICAL FOR 2 LEVELS.2" RIGID GALV. STEEL PIPEEMBEDDED IN CONC. FOOTING.FILL PIPE WITH CONC. & CAP.NEMA 4X PANEL.FASTEN PUMP PANEL ENCLOSURETO UNISTRUT (4) PLACES USING1/2" BOLTS & CAPTIVE NUTS.4" THICK CONCRETE PAD,MINIMUM DEPTH TO BE 12".FGCONDUITSNOTE: ALL HARDWARE TO BEGALVANIZED STEEL WITH 3' MIN.CLEARANCE ALL AROUND.18" DEEP x 12" DIA. CONCRETEPIER. MIN. 3" CONC. BELOWBOTTOM OF PIPE.WIDTH TO SUITEQUIPMENT WIDTHPUMP PANEL UNISTRUT MOUNTINGMICKE GROVE PARKPC77SEAL CONDUITTYPICAL1120/208/24015-203875C2CONTROL BOARD& CONTROLSCB2LINE230V, 1PH120V, 1PHTO MTR 1TO MTR 2CONTROLS23344(S)(S)(E) 'A'E E E E E EEEEEEEEEEEEEEEEEEE'SP'CIRCUIT UNDERGROUND PER PLANS DETAILSEE12.08.211FeederRe-routing1HORSEPOWERABOVE FINISHED GRADEUNLESS OTHERWISE NOTEDMANUFACTURERELECTRICAL CONTRACTORSUPPLIED BY VENDORNEW BY ECCIRCUIT (WIRE+CONDUIT)UNDERGROUNDTRANSFORMERHPAFGUONMFGREC(S)(N)CKTU.G.TX(E) U.G. PULL BOX W/2" PVC CONDUIT FROM PANEL 'A'(E) U.G. LIGHT CIRCUITS(E) U.G. LIGHT CIRCUITS5(E) 2"C, (N) 3-2/0, #6G(N) 1"C SPARE50'(E) U.G. BOX116666(E) 'TX'225KVA3.5%DRY TRANSFORMER PEDESTALKnow what's below.Call before you dig.(E) 'TX'5(E) 2"CCONDUIT STUB-UPICV
<br />ICVELELICV ICVICVICVSSMHRIM 40.06SSSSSSSS 4"PERF4"PERF4"PERF4"PERF4"PERF4"PERF4"PERF4"PERF4"PERF4"PERF4"PERF4"PERF4"SS 4"SS4"SSSS INVINV 38.04SS INVINV 37.79SS INVINV 37.78DELTACOVEREDPICNICSHELTERDANCEFLOORSTAGEKITCHEN &STORAGEAREAGRASS AREA
|