Laserfiche WebLink
SAN JOAQUIN <br />COUNTY <br />Environmental Health Department <br />J Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />LIONUDAKIS FIREWOOD <br />Facility Address: <br />20451 MCHENRY AVE, ESCALON <br />[rL--ruary 22 2022 <br />SUMMARY OF VIOLATIONS <br />A_ (cLAss I, cuss II, or NUNOR - Nodes to campy) <br />Item 0 <br />Remarks <br />718 <br />CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas. <br />OBSERVATION- The facility failed to promptly correct visible discharges of oil. The nozzle and hose for the 20,000 <br />gallon red diesel tank was observed act'vely leaking into the secondary containment berm Approximately 50 gallons <br />of liqu'd was observed inside the berm. <br />REGULATION GUIDANCE: (c)(10) Promptly correct visible discharges which result in a loss of oil from the <br />container, including but not limited to seams. gaskets piping pumps valves. rivets. and bolts You must promptly <br />remove any accumulations of oil in diked areas. <br />CORRECTIVE ACTION- Immediately fix any leak and remove all oil accumulations in diked areas, and manage all <br />wastes according to the California Code of Regulations Title 22 hazardous waste regulations, submit proof of <br />correction to the EMD. <br />This is a Class II violation. <br />CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable <br />containers_ <br />OBSERVATION: One blue plastic 55 gallon drum of waste fuel was observed outside the hazardous waste storage <br />area without secondary containment. <br />REGULATION GUIDANCE: (c)(11) Position or locate mobile or portable oil storage containers to prevent a <br />discharge as described in § 112.1(b). Except for mobile refuelers and other non -transportation -related tank trucks, <br />you must furnish a secondary means of containment, such as a dike or catchment basin, sufficient to contain the <br />capacity of the largest single compartment or container with sufficient freeboard to contain precipitation <br />CORRECTIVE ACTION: Provide adequate secondary containment for mobile or portable oil storage tanks Provide V <br />proof or correction to the EHD. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 3/24/2022 . <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018. all in -office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />The following was observed during this inspection: <br />- 20,000 gallon diesel tank <br />20,000 gallon red dye diesel tank <br />500 gallon hydraulic oil tank <br />- 300 gallon motor oil tank <br />FA0010254 PRO523036 SCO01 02/22!2022 <br />EHD 28.01 Rev 12M x2021 Page 8 of 9 Aboveground Petroleum Storage Act OIR <br />1868 E Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www slgov org/EHD <br />