Laserfiche WebLink
TWFWSDCDHWRHWCWGSSGWXXXITEMFIXTUREMANUFACTURER / MODEL NUMBERDESCRIPTIONF.C.O.FLOOR CLEANOUT OR CLEANOUT TOGRADEFWH.B.TWS.O.C.S.O.V.P.T.R.V.C.V.C.W.B.V.E.C.O.FUBFPEXTERIOR CLEAN OUTCOLD WATER BELOW GRADEFILTERED WATERPREMIXED TEMPERATURE WATERSHUT-OFF GAS COCKPRESS-TEMPERATURE RELIEF VALVESHUT-OFF GATE VALVEBALL VALVECHECK VALVEHOSE BIBBBACK FLOW PREVENTERFIXTURE UNITWALL CLEANOUTW.C.O.R.D.Y.B.ABBREV.SYMBOLSDESCRIPTIONYARD BOXROOF DRAINV.T.R.A.P.V.B.F.V.C.P.A.C.P.C.I.U.T.R.(E)H.D.F.D.F.S.OFDA.F.F.G.L.(N)NEWHUB DRAINGAS LINEABOVE FINISHED FLOORFLOOR SINKOVERFLOW DRAINCAST IRONVITRIFIED CLAY PIPEUP THRU ROOFASBESTOS CEMENT PIPEEXISTINGFLOOR DRAINVENT THRU ROOFACCESS PANELVENT BELOW FLOORGCWHWH.W.R.V.C.D.S.D.HOT WATER RETURNCONDENSATE DRAINSANITARY VENTSTORM DRAINGAS / GAS STUBHOT WATER / HW STUBCOLD WATER / CW STUBPLUMBING EQUIPMENT DESIGNATIONKITCHEN EQUIPMENT NUMBER: REFER TOSOIL OR WASTE (GREASE WASTE)/WASTE STUBKITCHEN EQUIP. DRAWINGS FOR DESCRIPTION.SOIL OR WASTE (SANITARY)/ WASTE STUBX-X0000SOIL ORWASTEVENTCOLDWATERHOTWATERTEMP'DWATERWASTEFUWATERFU1. SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE.2. ALL DRAWN WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED INPLACE.3. VERIFY THE LOCATION OF THE SANITARY SEWER ON THE SITE PLAN AND SHALL REVISE THE SEWER SYSTEM ASREQUIRED.4. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS IN RESTROOMS, WHERE REQUIRED BY CODES. PROVIDE DEEP SEALTRAPS FOR FLOOR DRAINS WITHOUT TRAP PRIMERS.5. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALLCLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC. AND THE OWNERS REPRESENTATIVE PRIOR TO ANYINSTALLATION.6. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVENON-ACCESSIBLE CEILING SHALL BE INSTALLED BEHIND AN ACCESS PANEL.7. ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACE AND10 FEET FROM ANY OUTSIDE AIR INTAKE.8. PROVIDE GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION.9. INSTALL SHUT-OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATERAND WASTE LINES TO BE CHROME PLATED.10. PROVIDE A LEVER HANDLE GAS SHUT-OFF VALVE IN THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OFEQUIPMENT, FOR EACH APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY CODE ANDRESTRAINING DEVICE FURNISHED BY OWNER. PROVIDE PRESSURE REDUCING VALVES AT EACH PIECE OFEQUIPMENT OR APPLIANCE. IF GAS PRESSURE GREATER THAN 10"/wc IS USED DOWNSTREAM FROM THE GASMETER.11. ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS.12. ALL FLOOR SINKS AND FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED FLUSH TO FLOOR SURFACE.13. PROVIDE WATER HAMMER ARRESTOR FOR ALL HAND SINKS AND URINAL WATER LINES.14. PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE. AIR GAP SHALL BE MINIMUM 2 TIMES THEDIAMETER OF THE INDIRECT DRAIN.15. PRIOR TO COMMENCING WORK ON THIS PROJECT, VERIFY DEPTH, SIZE, LOCATION AND CONDITION OF ALLEXISTING UTILITIES IN FIELD. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH WOULD CAUSETHE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY.16. COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TO AVOID UNNECESSARYDELAY OR INTERFERENCES. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS.17. FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIES HAVING JURISDICTION.BACKFLOW DEVICES REQUIRING TESTING SHALL BE INSTALLED NO HIGHER THAN 5'-0" A.F.F.18. ALL WATER LINES SHALL BE RUN OVERHEAD U.O.N.19. ALL WATER LINES SHALL BE FLUSHED PRIOR TO CONNECTING ANY FIXTURES OR EQUIPMENT.20. PROVIDE ESCUTCHEON PLATES AND SILICONE SEALANT AT ALL UTILITY PENETRATIONS INTO WALLS, CEILINGS,AND FLOORS. DO NOT USE CAULKS OR EXPANDING FOAMS FOR SEALANT.21. CVPVC SCHEDULE 40 WASTE PIPE CAN BE SUBSTITUTED FOR BLACK IRON WASTE PIPE WHERE ALLOWED BYLOCAL MUNICIPALITIES.22. PEX PLASTIC TUBING AND FITTING CAN BE USED AS AN OPTION, ALL INSTALLATION SHALL BE INSTALLED INACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND SHALL COMPLY WITH SECTION605.10.1 AND SECTION 605.10.2.23. ALL PLUMBING CONVEYING OR DISPENSING WATER FOR HUMAN CONSUMPTION SHALL COMPLY WITH AB 1953FOR LEAD CONTENT.24. GALVANIZED MALLEABLE IRON, GALVANIZED WROUGHT IRON, OR GALVANIZED STEEL ARE PROHIBITEDMATERIALS FOR WATER SUPPLY AND BUILDING WATER PIPING BOTH UNDERGROUND AND IN BUILDINGS.25. HOT WATER PIPE INSULATION SHALL HAVE A MINIMUM WALL THICKNESS OF NOT LESS THAN THE DIAMETER OFTHE PIPE FOR A PIPE UP TO 2 INCHES IN DIAMETER. INSULATION WALL THICKNESS SHALL NOT BE LESS THAN 2INCHES FOR A PIPE OF 2 INCHES OR MORE IN DIAMETER PER 2016 CPC 609.11.GREENGREENL1LAVATORY1-1/4"1-1/2"1/2"--1/2"21.5WHITE VITREOUS CHINA, WALL HUNG, WITH CONCEALED ARMS SUPPORT SEE 8/P6.0, 4"CENTERS, WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE. FLAT GRID STRAINER. BRAIDEDWATER LINES. FAUCET: FURNISHED BY OWNER-INSTALLED BY G.C.ELCTRONIC HANDWASHINGFAUCET, SLOAN BATTERY FAUCET , ADA COMPLIANT, 0.5 GPM AERATOR.A.S. COMRADE/ MODEL: 0124.131CRANE "HARWICH" / MODEL: 1412VSLOAN FAUCETS SF - 2350S.O.V.ANSUL SHUT-OFF GATE VALVEUUNION (LINE SIZE)P.O.C.POINT OF CONNECTIONEGENERAL NOTESDPLUMBING LEGENDWC1WATERCLOSET4"2"1/2"----42 AM. STD. "CADET" / MODEL: 2467.100KOHLER "HIGHLINE" / MODEL: K-3519CRANE "ECONMISER" / MODEL: 31888WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE,ELONGATED BOWL, ADA COMPLIANT, 1.1 GPF, WITH OPEN FRONT SEAT LESS COVER,OLSENITE #95 OR EQUIVALENT. FLUSHOMETER TANK: SLOAN FLUSHMATE OR EQUAL.PROVIDE TANK COVER LOCKS. FLUSH LEVERS SHALL BE RIGHT HAND OR LEFT HAND ASREQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDEREQUIREMENTSWCO1WALLCLEANOUT--------------WALL CLEANOUT INSTALLED PER MANUFACTURE SPECIFICATION, STAINLESS STEEL WALLACCESS COVER WITH CENTER SCREW, PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR.ZURN / MODEL: Z-1446APLUMBING SCHEDULEUR1URINAL2"1-1/2"3/4"----55WHITE VITREOUS CHINA, WALL HUNG, TOP INLET, ADA COMPLIANT, 1/8 GPF, WITH WALL HNGER.AM, STD, "WASHBROOK" / 6590.525SLOAN WEUS 1000, 1301-0, 13-ES-S P1.0CONTRACT DATE:BUILDING GROUP:FLOOR PLAN:SITE NUMBER:STORE NUMBER:REVISION DATE:PLOT DATE:ArchitecturalSolutions GroupPACIFIC BELLS, INC.111 W. 39TH STREETVANCOUVER, WA 98660360.694.7855TACO BELL1100 Yosemite AveEscalon, CA 95320K SUCCESSORREMODELME - K50MAY 2019-3418906.15.20NTP SUBMITTAL06.05.20CLIENT REVIEW07.09.201ST SUBMITTALSTATE OF CALIFORN IA LICENSED ARCHITECTRenewal: 6/30/21KENNETHMCCRACKENC-32095CITY USE ONLY:KJM/2620PLUMBINGSCHEDULESAND NOTES