My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
O
>
OLD HARLAN
>
15135
>
1600 - Food Program
>
PR0547525
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2022 4:09:18 PM
Creation date
2/28/2022 4:07:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547525
PE
1613
FACILITY_ID
FA0027027
FACILITY_NAME
DUTCH BROS COFFEE
STREET_NUMBER
15135
STREET_NAME
OLD HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
15135 OLD HARLAN RD
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P-13P-14EQ-9P-2EQ-12P-16P-1EQ-12EQ-12EQ-4EQ-4EQ-4P-7NOTE:AN APPROVED BACKFLOW PREVENTION DEVICE IS REQUIRED FORBEVERAGE MACHINES CONNECTED TO THE WATER SUPPLY PER 2015IPC.TANK-LESS WATER HEATERS SHALL BE NATIONALLY LISTED AND BEINSTALLED IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONSTHAT WERE APPROVED AS PART OF THEIR LISTING. THE GAS PIPINGSERVING THIS APPLIANCE MUST BE SIZED IN COMPLIANCE WITH THEWATER HEATER'S LISTED INSTALLATION INSTRUCTIONS PER 2015 IPC.STUB-OUTS FOR COFFEE EQUIPMENT AT TABLE SHALL BE 24"A.F.F.EQ-19EQ-19BP-1FWP-11P-10FWEQ-10EQ-11EQ-11EQ-11FW <br />P-10RTU1HWHWCWCWCWHWCW CWCWCWCWCW <br />FWHWHWR P-13HW EQ-4CWFW EQ-1RTU2FWEQ-1EQ-12EQ-19HW <br />CW <br />HWFW HWHWFWEQ-19EQ-12EQ-11EQ-1CW <br />FW FWMS-1PLUMBING KEYED NOTESROUTE NEW 1-1/2" WATER PIPING TO CONNECT TO WATER METER AND MAIN. VERIFY EXACT SIZE AND LOCATION IN FIELD. VERIFY WITHWATER COMPANY AND LANDLORD EXACT CONNECTION, DELIVERY PRESSURE AND METER REQUIREMENTS PRIOR TO WORK. WATERPIPING SIZE BASED ON 52 PSI INCOMING STATIC WATER PRESSURE. PROVIDE PRESSURE REDUCING VALVE IF PRESSURE IS OVER 80PSI. CONTACT ENGINEER IMMEDIATELY IF LOW PRESSURE (BELOW 60 PSI) OR DISCREPANCIES ARE FOUND FOR PIPING CHANGES.PROVIDE WATTS LF009 BACKFLOW PREVENTER ABOVE MOP SINK. ROUTE RELIEF PIPES TO DISCHARGE INDIRECTLY TO MOP SINK.WATER FILTRATION SYSTEM TO BE PROVIDED AND INSTALLED BY SELECTED WATER FILTRATION MANUFACTURER. PLUMBINGCONTRACTOR TO INSTALL BYPASS PIPING TO WATER FILTRATION SYSTEM.DROP 1/2" CW AND 1/2" FW LINES DOWN IN WALL ON WARM SIDE OF INSULATION TO BE RAN UNDER COUNTER TO SERVE FIXTURES.PROVIDE FULL SIZED BYPASS VALVES FOR THE MAIN CW LINE SERVING THE WATER FILTRATION SYSTEM.ROUTE TO CONNECT TO NEW GAS METER. GAS METER'S NEW DEMAND = 628MBH, (FIELD VERIFY ACTUAL LOCATION). APPROXIMATELENGTH FROM FURTHEST FIXTURE TO METER BANK 60'-0". CONTRACTOR TO VERIFY EXACT LENGTH, AVAILABLE PRESSURE ANDINSTALLATION LOCATION IN FIELD. VERIFY WITH GAS COMPANY FOR EXACT CONNECTION AND METER INSTALLATION GUIDELINES ANDREQUIREMENTS PRIOR TO ANY WORK.PROVIDE CIRCULATING PUMP. SEE PLUMBING FIXTURE SCHEDULE ON DRAWING P1.0 FOR ADDITIONAL INFORMATION.NOT USED.COLD WATER DOWN FROM TRAP PRIMER TO FLOOR DRAIN. SEE DETAIL ON DRAWING P3.0 FOR MORE INFORMATION.PIPING TO BE RAN LOW IN WALL BELOW WINDOW.NOT USED.ROUTE EXPOSED COLD WATER PIPING DOWN TO COUNTER AND TO RAPID RINSE.PROVIDE EARTHQUAKE-ACTUATED GAS SHUT OFF VALVES, AT GAS METER ON SUPPLY TO BUILDING, INSTALL PER MANUFACTURER'SRECOMMENDATIONS.INSTALL BOOSTER PUMP SYSTEM ON PLATFORM ABOVE MOP SINK. INSTALL PER MANUFACTURERS GUIDELINES, PROVIDE WITH ALLNECESSARY VALVES AND ACCESSORIES FOR A COMPLETE SYSTEM. COORDINATE EXACT INSTALLATION OF ALL SYSTEM COMPONENTSIN FIELD PRIOR TO ANY WORK AS DRAWING IS SHOWN DIAGRAMMATICALLY ONLY.1/2" COLD WATER DOWN TO FREEZE PROOF WALL HYDRANT.1/2" COLD WATER LINE TO YARD HYDRANT. VERIFY LOCATION IN FIELD.WATER FLOOR PLAN1P1.0SCALE: 1/2" = 1'-0"EQ-1EQ-4D:\my Documents\DJC-CA.jpgSHEET NAME:SHEET NUMBER:DESCRIPTION:DATE:REV:ISSUED FOR PERMIT:03.20.20““”“””c1001 SE SANDY BLVD, SUITE 100PORTLAND, OR 97214V. 503.552.9079F. 503.241.7055WWW.GNICHARCH.COM03.20.20796 Merus CourtSt. Louis, MO 63026T 636.349.1600F 636.349.1730Project No: CA-0805 <br />Dutch Bros Coffee - New Freestanding Store <br />15135 Old Harlan Road <br />Lathrop, CA 95330 <br />for: Cherng Family Trust <br />1120 N. Town Center Drive, Suite 150 <br />Las Vegas, Nevada 89144 DB2040 - A1P3.0PLUMBING SUPPLYFLOOR PLAN ANDDETAILS
The URL can be used to link to this page
Your browser does not support the video tag.