Laserfiche WebLink
i I <br /> A D F <br /> O I I O O <br /> H <br /> ....... .... <br /> -- N <br /> x o c' <br /> I-- <br /> ><w N <br /> _ ti <br /> L3CYD <br /> x � � o <br /> o CnQ � <br /> � o � <br /> I NN <br /> m <br /> oti <br /> co <br /> 1 - - - - CD Cn <br /> C)__4 <br /> E � <br /> D <br /> 3 - <br /> 85 1 <br /> CD-3. <br /> A <br /> 1.2x12 CD-4 �.. I o o 0 o <br /> 0 - 150 .CFM I 12 Q: I■ Store: <br /> .50 o 0 <br /> 4 KETTLEMAN & L. SACRMENTO <br /> �.... 150 19 3 .1 I.D. <br /> CD-1 -o = LODI, CA 95242 <br /> o O Zouo:i I o 0 1 <br /> ° 10;o 8, �•J r <br /> _ Restaurant #RC576 <br /> o 1501 CFM I ... .. IO MAKE-UP o `1 2 I o o HE <br /> SCHEME A <br /> CD- CD=•3 AIR UNIT2 I Professional of Record: NAME <br /> 15 F-1 � r A 4 <br /> I <br /> 0 7. <br /> 50 5 <br /> C O <br /> 12x12 20 r •�• I ° <br /> • I150 CFM I I <br /> 8x24 0/ . <br /> _ - 21 KITCHEN 00 I g. �/ <br /> c c EXHAUST A OD <br /> 6 <br /> 275 - 250 - O MAKE-UP I I I o 385 o I■ ROBISON <br /> AIR UNIT1 I I O O O <br /> o N I I . . O . .�O <br /> Ac 1 I N N00 ENGINEERING, INC <br /> I x 19401 40TH AVE W.,SUITE 302 <br /> I 2 EACH \ 0 LYNNWOOD,WA 98036 <br /> 5 I C EN 0 CD-2. 2063643343 TEL <br /> X A ST A o C <br /> L_ O O . . 7 _ REI# 424-1551 <br /> 6x20 16 16 10x10 X. . .. . . I 4 I 13 <br /> SD 6 EAC I . . • . <br /> 5 10 14 I N I I O 16 <br /> SD KITCHEN HOOD O <br /> 6„� RTU-2 EXHAUST FAN1 4 EACH <br /> C I 23 0 22 RTU 11 <br /> 50 25 X <br /> . . I 28 O O II QROFESS/pN <br /> 27' :SWG 1 x1 O EACH O I . . . . . . . . . . I I II 2 <br /> 60 CFM M 2871 <br /> _ •: II � Z <br /> 3' w <br /> O7 16x18 12x14 <br /> 12x Q ii E 0-21 <br /> 11 T I . . �. 8'I <br /> .. . 12" I• OF cps\ <br /> - II <br /> Q C C 1 20 18x 8 1 I CD-2 19 <br /> O 0. . . . .O .Oc 0. . <br /> CD-1 12/21/20 <br /> fT 10. <br /> © I I . . • . • . 300 . . <br /> O 250 I . O <br /> o Prototype: P4E- HV 2020 -2.0 RELEASE <br /> AC-2 . • . . A�/ Prototype Issue Date: 7.14.2020 <br /> -- <br /> Design Bulletin Updates: <br /> 11 � - J �= Date Issued: Bulletin Number: <br /> N 1HVAC FLOOR PLAN <br /> 1ST BLDG. SUBMITTAL <br /> I <br /> 2 <br /> I <br /> MECHANICAL SYMBOL SCHEDULE 3 KEYNOTES <br /> RA RETURN AIR Q1 THERMOSTAT FOR RTU-1, OTHERS SIMILAR O 28" x 20" RECTANGULAR SUPPLY DUCT DOWN FROM UNIT. TRANSITION TO TWO O ANSUL FIRE SUPPRESSION SYSTEM BOX (PULL STATION), RE: FOOD SERVICE 19 PROVIDE FACTORY-FABRICATED GALVANIZED ANGLE RING FLANGE WITH REVISIONS: <br /> HORIZONTAL BRANCH DUCTS AS SHOWN ROUTED BETWEEN TRUSSES. RECTANGULAR ELEVATIONS FOR EXACT MOUNTING LOCATION. PULL STATION SHALL BE LOCATED PRE-PUNCHED HOLES AT DUCT PENETRATION THROUGH WALL TO SERVE AS AN 12.22,2020 1st Building Submittal <br /> DUCTS CONCEALED FROM VIEW SHALL BE WRAPPED, RE: 1M3.2 FOR MECHANICAL BETWEEN MAXIMUM 20' AND MINIMUM 10' FROM EXHAUST SYSTEM WITHIN PATH OF ESCUTCHEON. <br /> SA SUPPLY AIR Q FIRESTAT - 125 DEG. F SPECIFICATIONS. EGRESS. BETWEEN 421NCHES AND 481NCHES ABOVE THE FLOOR. MC TO FIELD 1 <br /> EXH EXHAUST AIR so DETERMINE FINAL LOCATION OF PULL STATION WITH GC AND PM PRIOR TO BID AND 20 TRANSITION FROM UNIT OPENING TO 18" x 24" WRAPPED SUPPLY DUCT DOWN FROM 2 <br /> O RETURN/SUPPLY AIR SMOKE DETECTOR O 20"O.D./18"I.D. ROUND LINED SPIRAL DUCTWORK ROUTED IN TRUSS CHASE. RE: INSTALLATION. MAKE-UP AIR UNIT2. TRANSITION AS SHOWN AND CONNECT TO TWO 8" x 26" 3 <br /> OA OUTSIDE AIR 1M3.2 FOR MECHANICAL SPECIFICATIONS. SUPPLY PLENUM DUCT COLLARS. RE: 2M3.1 FOR HOOD2 DETAIL AND 4M3.1 FOR <br /> OS OCCUPANCY SENSOR 10 16" x 60" WRAPPED RECTANGULAR RETURN AIR DUCT DOWN FROM UNIT. MAKE-UP AIR UNIT DETAIL. CONTINUE TRANSITION AS SHOWN AND CONNECT TO 4 <br /> O3 20"O.D./18"I.D. ROUND, EXPOSED, LINED SPIRAL DUCTWORK MANIFOLD WITH TRANSITION TO HORIZONTAL 20" x 30" DUCT ROUTED WITHIN TRUSS CHASE. THREE 12" x 28" SUPPLY PLENUM DUCT COLLARS. RE: 1M3.1 FOR HOOD1 DETAIL 5 <br /> RE: 2M1.1 REFER TO DETAIL 2, SHEET M1.1 1 FACTORY-FABRICATED TEE FITTINGS, ELBOWS, AND END CAPS. RE: 6M2.1 FOR RECTANGULAR RETURN DUCT SHALL BE WRAPPED. AND 4M3.1 FOR MAKE-UP AIR UNIT DETAIL <br /> Q REMOTE TEMPERATURE AND HUMIDITY SENSOR DUCT SUPPORT DETAIL. RE: 1M3.2 FOR MECHANICAL SPECIFICATIONS. DUCT SHALL 6 <br /> O REFERENCE TO MECHANICAL FOR RTU-1, MOUNT WHERE INDICATED ON BE ROUTED WITHIN TRUSS CHASE. 11 GAS WATER HEATER BY PLUMBING CONTRACTOR. 21 PROVIDE 6" ROUND SPIN-TAP FITTING BALANCED TO 50 CFM TO SUPPLY AIR INTO 7 <br /> KEYNOTE NUMBER 1. DRAWINGS, OTHERS SIMILAR. CEILING CAVITY. LOCATE ABOVE LAY-IN CEILING FOR ACCESSIBILITY. COVER <br /> O 14" O.D./12" I.D. ROUND, EXPOSED, LINED SPIRAL DUCTWORK ROUTED BETWEEN 12 24" x 28" WRAPPED RECTANGULAR RETURN AIR DUCT DOWN FROM UNIT. CONNECT FITTING WITH DUCT WRAP INSULATION. 8 <br /> RETURN AIR GRILLE IN CEILING. SEE PLAN ,.� TRUSSES TO CONNECT TO SUPPLY DIFFUSER. 24" x 30" HORIZONTAL DUCT AS SHOWN ROUTED WITHIN TRUSS CHASE. 24" x <br /> � FOR SIZE. U DIFFERENTIAL TEMPERATURE SENSOR FOR HOOD 30" RECTANGULAR DUCT SHALL BE LINED, RE: 1M3.2 FOR MECHANICAL 22 ROUTE 12" I.D. KITCHEN HOOD EXHAUST DUCT OR EQUIVALENT, WITH 2 LAYERS OF <br /> O TRANSITION FROM UNIT OPENING TO 16" x 18" WRAPPED SUPPLY DUCT DOWN FROM SPECIFICATIONS. 1-1/2" FIRE-RATED WRAPPING FULL SIZE DOWN FROM KITCHEN HOOD EXHAUST <br /> <9> <br /> TYPE "B" CEILING DIFFUSER (4 WAY THROW UNLESS REMOTE CO2 SENSOR FOR RTU-1, MOUNT MAKE-UP AIR UNIT1. TRANSITION AS SHOWN AND CONNECT TO THREE 8" x 36" FAN2. RE: 2M3.1 FOR HOOD2 DETAIL AND 4M3.1 FOR EXHAUST FAN DETAIL. RE: <br /> B NOTED OTHERWISE). BALANCE TO 200 CFM, SEE WHERE INDICATED ON DRAWINGS LOCATED SUPPLY PLENUM DUCT COLLARS. RE: 3M3.1 FOR HOOD3 DETAIL AND 4M3.1 FOR 13 24" x 30" LOUVERED RA GRILLE, RE: AIR DEVICE SCHEDULE. ARCHITECTURAL FOR HOOD LOCATION DIMENSIONS. Sheet Title: <br /> 200 BETWEEN 3 AND 6 FT ABOVE FLOOR, OTHERS MAKE-UP AIR UNIT DETAIL. <br /> EQUIPMENT SCHEDULE, OTHERS SIMILAR. <br /> SIMILAR. 14 TWO 28" x 20" RECTANGULAR SUPPLY DUCT DOWN FROM UNIT. TRANSITION TO 23 ROUTE 16" I.D. KITCHEN HOOD EXHAUST DUCT OR EQUIVALENT, WITH 2 LAYERS OF HVAC FLOOR <br /> CEILING DIFFUSER WITH 3 WAY THROW. SHADED © ROUTE 16" I.D. KITCHEN HOOD EXHAUST DUCT OR EQUIVALENT, WITH 2 LAYERS OF HORIZONTAL BRANCH DUCTS AS SHOWN. ROUTED BETWEEN TRUSSES AND TRUSS 1-1/2" FIRE-RATED WRAPPING FULL SIZE DOWN FROM KITCHEN HOOD EXHAUST <br /> QUADRANTS REPRESENT NO AIR FLOW, OTHERS SIMILAR. 1-1/2" FIRE-RATED WRAPPING FULL SIZE DOWN FROM KITCHEN HOOD EXHAUST CHASES. RECTANGULAR DUCTS CONCEALED FROM VIEW SHALL BE WRAPPED, RE: FAN1. RE: 1M3.1 FOR HOOD1 DETAIL AND 4M3.1 FOR EXHAUST FAN DETAIL. RE: PLAN <br /> FANS. RE: 3M3.1 FOR HOOD-3 DETAIL AND 4M3.1 FOR EXHAUST FAN DETAIL. RE: 1M3.2 FOR MECHANICAL SPECIFICATIONS. ARCHITECTURAL FOR HOOD LOCATION DIMENSIONS. <br /> MECHANICAL SHEET INDEX ARCHITECTURAL FOR HOOD LOCATION DIMENSIONS. O O <br /> DUCT TURNING VANE 15 PROVIDE NOMINAL 48" x 24" LOUVERED RA GRILLE, RE: AIR DEVICE SCHEDULE. 24 PROVIDE SEVEN 8"0 SUPPLY DUCT CONNECTIONS TO HOOD1 AC-PSP. BALANCE Date: 12.07.2020 <br /> " M1.1 HVAC FLOOR PLAN O THERMOSTAT SERVING RTU-1 SHALL BE PERMANENTLY/PROFESSIONALLY LABELED CONNECT GRILLE FULL SIZE FROM GRILLE OPENING TO RA DUCT FROM UNIT. EACH OUTLET TO 109 CFM. <br /> "DINING." THERMOSTAT SERVING RTU-2 SHALL BE PERMANENTLY/PROFESSIONALLY <br /> 6x6 OR �x� 6x6 RECTANGULAR DUCT M1.2 HVAC ROOF PLAN LABELED "KITCHEN. 16 INSTALL ROUND SUPPLY DIFFUSERS IN AREAS WITH EXPOSED STRUCTURE FLUSH TO 25 PROVIDE FOUR 8"0 SUPPLY DUCT CONNECTIONS TO HOOD2 AC-PSP. BALANCE Project Number: RAC19048.0 <br /> M2.1 HVAC SCHEDULE AND DETAILS BOTTOM SIDE OF STRUCTURAL TRUSSES. EACH OUTLET TO 100 CFM. <br /> 12"0 <br /> M3.1 KITCHEN HOOD DETAILS AND HVAC SPECS O8 ROOF-MOUNTED EXHAUST FAN. ROUTE 10" x 10" WRAPPED EXHAUST DUCT FULL Drawn By: _ <br /> 12 b OR �� 12" DIAMETER ROUND DUCT M3.2 KITCHEN HOOD NOTES AND HVAC SPECS SIZE DOWN FROM FAN TO SPACE ABOVE CEILING. CONNECT 8"/10" ROUND BRANCH 17 INSTALL ROUND SUPPLY DIFFUSERS IN AREAS WITH HARD CEILINGS 26 PROVIDE SIX 8"0 SUPPLY DUCT CONNECTIONS TO HOOD3 AC-PSP. BALANCE EACH <br /> M3.3- SURFACE-MOUNTED TO CEILING. OUTLET TO 112 CFM. <br /> DUCTS AS SHOWN. RE: 4M2.1 FOR EXHAUST FAN DETAIL. <br /> OPPOSED BLADE DAMPER M3.10 HOOD DRAWINGS (FOR REFERENCE) <br /> M4.1 HVAC SPECS AND CALGREEN NOTES 1$ PROVIDE REMOTE DAMPER OPERATORS FOR BALANCING DAMPERS ACCESSIBLE FROM 27 INSTALL UNIT HEATER IN RISER CLOSET PER MANUFACTURER'S INSTRUCTIONS, RE: <br /> M4.2 FIRE WRAP DETAILS CEILING ACCESS DOOR. M2.1 FOR SCHEDULE. Sheet Number:I <br /> 'DUCT <br /> MANUAL BALANCING DAMPER (MBD) M5.1- <br /> DUCT M5.3 T24 FORMS <br /> J <br /> Q <br /> 1- <br /> G <br /> 4 <br /> 1<1 <br /> Mi ' l <br /> m <br /> M <br /> N <br />