Laserfiche WebLink
ELECTRICAL SYMBOL SCHEDULE <br /> --❑, —0 POLE MOUNTED LIGHTING FIXTURE. RE: 3E4.2 <br /> 1-1/2" EC EMPTY CONDUIT WITH PULL WIRE. EMPTY CONDUIT — y <br /> LIGHTING FIXTURE TYPE A: CONNECT TO CIRCUIT NO. 1 IN PANEL RUN TO ABOVE CEILING SHALL TERMINATE IN A 19 <br /> A-1 A. CONNECT TO SWITCH INDICATED BY LETTER "a". WHERE NO _ — o <br /> A,a BUSHING AND BE BENT/INSTALLED SUCH THAT 0'-6" N m <br /> LETTER IS SHOWN, CONNECT TO SWITCHES) (SINGLE POLE OR MINIMUM OF CONDUIT IS PARALLEL WITH CEILING o <br /> THREE—WAY) IN ROOM. PLANE. <br /> U � <br /> EXIT LIGHT: SHADED AREA DENOTES FACE. WALL MOUNT WHEN a TELECOMMUNICATIONS OUTLET. UNLESS NOTED w o o <br /> SHOWN WITH BRACKET, CEILING MOUNT OTHERWISE. COORDINATE OTHERWISE, ROUTE TWO 3/4" CONDUITS CONCEALED x o _CZ x <br /> WITH DOOR SWINGS. ARROW(S) AS NOTED. TO ACCESSIBLE CEILING AND/OR ATTIC SPACE AND W I <br /> TERMINATE WITH A BUSHING. CONDUIT SHALL BE L3 cit CZ o0 <br /> CEILING FAN BENT/INSTALLED SUCH THAT 0'-3" MINIMUM OF X M � m <br /> CONDUIT IS AT 45 DEGREES FROM HORIZONTAL WITH+ =o a; <br /> CEILING PLANE. PROVIDE PULL STRING IN ALL = co <br /> �P WALL MOUNTED EMERGENCY BATTERY BACKED UP LIGHTING FIXTURE. CONDUIT ROUTES 2' OR GREATER. CL m N <br /> C=) r-- <br /> C=) <br /> LC <br /> A FLUSH MOUNTED PANEL. LINE DENOTES PANEL DOOR. � <br /> LIGHTING CONTACTOR a; <br /> CD <br /> PC PHOTOCELL FOR DAYLIGHT SENSING — — — CONDUIT RUN CONCEALED UNDER FLOOR OR ` e _ ~ <br /> UNDERGROUND <br /> SINGLE POLE TOGGLE SWITCH <br /> $F FAN CONTROL SWITCH DISCONNECT SWITCH WITH EQUIPMENT GROUND LUG <br /> 60/3/NP (SIZE/POLE/FUSE SIZE): 60A, 3 POLE SWITCH, <br /> $P TOGGLE SWITCH WITH PILOT LIGHT. SWITCH SHALL BE 120/277V, FUSED AS PER NAMEPLATE OF EQUIPMENT SERVED BY <br /> 20A RATED. PILOT LIGHT SHALL BE ENERGIZED IN ON POSITION SWITCH. <br /> ONLY. 60/3 DISCONNECT SWITCH WITH EQUIPMENT GROUND LUG Store: <br /> $OS WALL MOUNTED OCCUPANCY SENSOR SWITCH D (SIZE/POLE): 60A, 3 POLE, NON—FUSIBLE SWITCH. KETTLEMAN & L. SACRMENTO <br /> SINGLE POLE DIMMER SWITCH <br /> DUPLEX RECEPTACLE F- - —1LORI MECHANICAL EQUIPMENT CONNECTED BY ELECTRICAL. RE: , CA 95242 <br /> LRTU—J MECHANICAL EQUIPMENT SCHEDULES FOR DESCRIPTION. <br /> QUAD RECEPTACLE Restaurant #RC576 <br /> DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTION O REFERENCE TO ELECTRICAL p <br /> KEYNOTE NUMBER 1. P4E-HV-M SCHEME A <br /> GFCI PROTECTION FACP FIRE ALARM CONTROL PANEL <br /> IG <br /> DUPLEX RECEPTACLE WITH ISOLATED GROUND Q JUNCTION/PULL BOX Professional of Record. NAME <br /> CONTROLLED DUPLEX RECEPTACLE <br /> ® SPECIAL RECEPTACLE, SEE PLANS. O POWER AND DATA FOR TV TO BE LOCATED IN THE <br /> CEILING ABOVE NOTATION. WIRES ARE TO BE ROUTED <br /> DOWN THE SCREEN MOUNTING STRUCTURE. COORDINATE iff <br /> WP WEATHERPROOF, NEMA 3R OR AS NOTED ON PLANS. THE EXACT LOCATION WITH THE ARCHITECTURAL <br /> RE: 1E2.1 REFER TO DETAIL 1, SHEET E2.1. ELEVATIONS PRIOR TO ROUGH—IN. <br /> CLG RECEPTACLE MOUNTED IN LAY—IN CEILING. COORDINATE DEVICE FK—DS] KIDS BUMP BAR AND MONITOR. PROVIDE A RECEPTACLE <br /> AND PLATE COLOR WITH ARCHITECT. CONNECTED TO THE NOTED CIRCUIT AND A <br /> © BUZZER COMMUNICATION OUTLET (SEE SYMBOL ABOVE FOR ROBISON <br /> PB PUSHBUTTON ASSEMBLY DETAILS). COORDINATE LOCATION WITH ARCHITECTURAL <br /> ELEVATIONS. KIDS OUTLETS ARE TO BE INSTALLED INSIDE ENGINEERING, INC <br /> THE WALL WITH A JUNCTION BOX & ACCESS PANEL. 1940140TH AVE W..SUITE 302 <br /> NL NIGHT LIGHT. FIXTURE CIRCUITED TO AN UNSWITCHED LYNNWOOD,WA 98036 <br /> CONDUCTOR OF THE CIRCUIT INDICATED. O FIRE ALARM SMOKE DETECTOR IN SUPPLY AND/OR RETURN AIR 206-3643343TEL <br /> 48" AFF MOUNT 48" ABOVE FINISHED FLOOR TO CENTER LINE. DUCT. <br /> 0 FIRE ALARM SMOKE DETECTOR. REi# 424-1551 <br /> © DAYLIGHT HARVESTER. PROVIDE MODEL NLIGHT/NCM � FAP FIRE ALARM PANEL <br /> ADCX (RJB) OR APPROVED EQUAL <br /> PP RELAY MODULE. PROVIDE MODEL NLIGHT/NPP16D RAP FIRE ALARM REMOTE ANNUNCIATOR PANEL. PROVIDE 3/4"C TO <br /> ASSOCIATED FIRE ALARM PANEL. <br /> 0 WALL NLIGHT CONTROLLER. PROVIDE MODEL NLIGHT FS SPRINKLER SYSTEM FLOW SWITCH, CONNECT TO FIRE ALARM <br /> NPODM 4S DX. PROVIDE FOR PROGRAMMING OF SYSTEM. QROFESS/ <br /> SYSTEM TO WORK AS SPECIFIED ON SHEET E2.2 WITH TS SPRINKLER SYSTEM TAMPER SWITCH, CONNECT TO FIRE ALARM <br /> EACH SWITCH DESIGNATION TO BE CONTROLLED WITH 0 SYSTEM. <br /> ONE SCENE EACH. C Z <br /> No. E-23059 m <br /> LV LOW VOLTAGE OCCUPANCY SENSOR. PROVIDE MODEL ;;0NLIGHT NCM PDT 9 (RJB) EXP. 3— 1— <br /> LINE VOLTAGE OCCUPANCY SENSOR. PROVIDE MODEL qTF OC \F0� <br /> OS SENSOR SWITCH CMR—PDT-9 OR APPROVED EQUAL. CAL <br /> 12/21/20 <br /> Prototype : P4E- HV 2020 - 2.0 RELEASE <br /> Prototype Issue Date: 7.14.2020 <br /> Design Bulletin Updates: -- <br /> Date Issued: Bulletin Number: <br /> 1ST BLDG. SUBMITTAL <br /> REVISIONS: <br /> 12.22.2020 1st Building Submittal <br /> 1 <br /> 2 <br /> 3 <br /> 4 <br /> 5 <br /> 6 <br /> 7 <br /> 8 <br /> Sheet Title: <br /> ELECTRICAL <br /> COVER SHEET <br /> ELECTRICAL SHEET INDEX Date: 12.07.2020 <br /> E0.0 ELECTRICAL COVER SHEET Project Number: RAC19048.0 <br /> E1.0 ELECTRICAL SITE PLAN <br /> E1.2 ELECTRICAL SITE PHOTOMETRICS <br /> E2.1 POWER FLOOR PLAN Drawn By: _ <br /> E2.2 LIGHTING FLOOR PLAN <br /> E2.3 POWER ROOF PLAN <br /> E3.1A RISERS, SCHEDULES AND DETAILS <br /> E3.1B RISERS, SCHEDULES AND DETAILS <br /> E3.2 LIGHTING FIXTURE SCHEDULE Sheet Number: <br /> E3.3 ELECTRICAL DETAILS <br /> E4.1 ELECTRICAL SPECIFICATIONS <br /> E4.2 ELECTRICAL SPECIFICATIONS <br /> E4.3A ENERGY CODE COMPLIANCE <br /> E4.3B ENERGY CODE COMPLIANCE <br /> E4.4 VOLTAGE DROP CALCULATIONS EO . 0 <br /> Q <br /> m <br /> COPYRIGHT 2020, ROBISON ENGINEERING, INC. <br /> ,ESCALONA F.\_PEDRO+MCCRACKEN\_RAISING CANES\424-1551 LODI, CA R00576\DWG\EOOP4.DWG 12-21-2020 11:56 <br />