Laserfiche WebLink
6 <br /> Z <br /> 0 <br /> 1 A I 114r-7117-ri III h fi A III I I K 120- 23 <br /> VV rxr-- I I L-LIVIAN LIN <br /> Irrigation Equipment Schedule <br /> 0 <br /> o symbol on plan description brand and model detail requirements <br /> 0 1-1/2" and smaller: SCH 80 PVC, 1-1/2"and smaller:depth of cover 18"MIN. <br /> new mainline pipe for potable water W/SCH 80 PVC fittings. 2 2"and larger:depth of cover 24"MIN.;identify pipe W/ <br /> w/blue 3" identification tape 2" and larger: Class 315 PVC W/ (3")minimum width tape with(1")contrasting lettering <br /> / \\ SCH 80 PVC fittings. L2.5 bearing the coninutous wording"Potable Water" <br /> 2 depth of cover : 12" MIN. <br /> ® -� new lateral line pipe SCH 40 PVC, lateral pipes to be 1" unless otherwise noted; <br /> for potable water W/SCH 40 PVC fittings L2 5 no class 200 pipe is to be used. <br /> depth of cover . same as main and laterals. <br /> ............................. sleeveI e for main, laterals and SCH 40 PVC, W/SCH 40 3 glue all couplings; sleeve size to be MIN. 2.5x <br /> i �I \ ----------------- - wires under paving and through walls PVC couplings diameter of passing pipe; shallow depth under K I E S E L D E S I G N <br /> II I 0 0 L2.5 paving is not permitted. <br /> 1 weather-based irrigation controller, HUNTER A2C-1200-SS 2 confirm location with owner prior to installation; Kiesel Landscape <br /> C exterior wall mount w/rain sensor Smart Modular Control System L2 3 install per manufacturer's instructions. <br /> Z 7 Architecture, Inc. <br /> 7.06 gpm $ I II I I <br /> DRP LOW I II II W backflow preventer assembly 1" FEBCO LF825YA-QT RT <br /> 1.00 in I 1"WILKINS SXL Wye strainer 1 <br /> I <br /> 1"WILKINS 500XL res. reducer install per City Health Code requirements pressure educeand strainer " brass unions p L2.3 422 E Main Street <br /> 2.50 m <br /> 7 I III - Ventura CA 93001 <br /> � I /�. ►tj I \ <br /> BUBBLER 1.00 in / I I �� g RAINBIRD PVB tan colored 10" rounded valve (p) 805.947.0730 <br /> LOW ® _ ___ / w ball valve mainline shut off SPEARS, true union, with box, coordinate exact location W/planting plan, <br /> VITON o-rings, line size L2.3 conceal in planting if possible. Jack@kieseldesign.com <br /> 2 confirm location with Owner prior to installation. C L# 5206 <br /> III I \ I rain sensor(rain actuated) RAINBIRD WR2-RCinstall per manufacturer's instructions in location <br /> / III <br /> 18 \ I I I L2.3 free of overhead obstruction. <br /> III I III I 1 1.43 qpm bubbler valve, W/ACCU-SYNC 7 RAINBIRD PVBSTDT green colored valve <br /> \11.0DRIP LOW adjustable pressure regulator; HUNTER ICV-101 G -AS-ADJ box,coordinte location W/planting plan; <br /> I �\ I I / field set to provide 40PSI dynamic L2 8 adjust pressure to provide 40PSI downstream Raising Cane's Lodi <br /> WJ 11 I I \\ I // pressure regulating drip valve 3/4"-HUNTER ICZ-075-25 4 RAINBIRD PVBSTDT green colored RC #576 <br /> I / r \ assembly, with basket filter - valve box, coordinte location W/planting <br /> �\ I III / I � I TTTI / L2.4 plan 2380 W Kettleman Ln <br /> ■ I -t Lodi, CA 95242 <br /> \ III master valve, normal) BUCKNER SUPERIOR 3200-100 RAINBIRD PVBSTDT tan colred valve box, <br /> IN,\ I\ / I I /� r y closed 1" solenoid controled master valve L2 3 install in planting as shown on sheet L2.1. <br /> U / �� / I IIII ��� <br /> r" /// I `\ I I I I \ ♦ flow sensor RAINBIRD FS100B 5,6 RAINBIRD PVBSTDT tan colred valve box, <br /> I I I 1 brass flow sensor module L2 3 install in planting as shown on sheet L2.1. <br /> / <br /> I I i 1 I I I air release valve kit RAINBIRD ARVALVEKIT 3 install MIN. (1) air release valve kit for each valve Revisions: <br /> RAISING CANES I I I Air Relief Valve at hydrozone high point, per detail sheet L2.5 <br /> I � I I I L2.4 # DATE NAME <br /> I III I I PROTOTYPE 4E-HV <br /> 3,267 GROSS S.F. \ I RAINBIRD Flush Cap: MDCFCAP 2 12.21 .20 1st Building Submittal <br /> no symbol manual flush valve RAINBIRD Easy Fit Coupling: <br /> MDCFCOUP plumb to tubing per details#1 &#7, sheet L2.4 <br /> L2.4 <br /> 1 brass quick-coupling valve with g <br /> quick-coupling valve confirm location with owner prior to installation; <br /> _LL Iu I x corrosion-risistant stainless steel install per manufacturer's instructions. <br /> 4 -I� spring, locking 2-piece body./ 2 4.72 gpm <br /> ® \ <br /> I I I � 1.00 in LOW <br /> / I I \ .25 GPM, pressure compensating RAINBIRD RWS-S-B-1401 7 position evenly spaced around root ball. <br /> 2 I <br /> \\ 4- (20-90PS1) below grade tree bubbler; L2 4 do not damage root ball. <br /> I 3 <br /> 3 I 2.50 m 0.4 GPH subsurface drip irrigation; burial depth: 4" -coordinate layout <br /> I I I I I 1 BUBBLER 0.4 in/hr reci rate @ 30 or 40 PSI RAINBIRD EFS 04 18 5,6 with planting Ian, see plantingsheets; <br /> / I 1.00 in LOW p p' RAINBIRD Easy Fit p g p r <br /> 4 I I I space drip lines at 18 O.C.; Compression Fittings L2 4 space drip lines at 18 O.C.; <br /> _ install laterals parallel to grade p g install laterals parallel to grade <br /> Lin 4 2.10 qpm <br /> \ / / 1.00 in DRIP LOW Pipe Transition point from PVC 8 <br /> Pipe Transition point in Drip Box lateral to drip tubing with riser in install per detail DSCAp <br /> 6" drip box. L2.4 geselS 9�0� <br /> IIII I , �/ / c D <br /> 1' � /�/ // \\ I I IIII <br /> � o r <br /> lace as close as possible to corresponding <br /> o 0 0 / / drip system operation indicator; 1 p p p g U <br /> / 00 I / / i no symbol one per drip valve assembly RAINBIRD OPERIND drip valve assembly; bury indicator to be flush a IIII <br /> --Lij L2 4 with finish grade "ztUe <br /> 12.31.22 <br /> HYDROZONE/ valve number: brand into lid of valve box with 1 1/4" high 1 b 2l 20� ` <br /> VALVE NUMBER numbers corresponding to controller stations, using a s Date Q- <br /> / I XXL GPM valve designation on plan CHRISTY'S brander and dies, or equal. valve numbers on <br /> 6 VALVE SIZE p suggested OF ALLF <br /> 1.50 m I III 1 WATER USE Ian are su ested order. 1F o¢ <br /> BUBBLER 1.�in I I III .�'. c <br /> /III <br /> LOW <br /> 5 - <br /> 3.72 qpm \ <br /> DRIP LOW 1.00 in <br /> Type: 1st Building Submittal <br /> Irrigation Valve Schedule <br /> I <br /> r - - \� - -_ _ I Zone ID Symbol Type Manufacturer Series Model Size Design Flow <br /> - I 1 Zone Kit Hunter Industries R Drip Control Zone Kits ICZ-101-LF-25 1 1.435 Initial Setup Date: <br /> 61 2 Zone Kit Hunter Industries R DripControl Zone Kits ICZ-101-LF-25 1 4.718 June 30, 2020 <br /> I 51 I ® �/ \ 3 Control/Zone Hunter Industries R ICV ICV-101G 1 2.5 <br /> 1 / \ 4 1 Zone Kit Hunter Industries R Drip Control Zone Kits ICZ-101-LF-25 1 2.1 <br /> \ 5 Zone Kit Hunter Industries R Drip Control Zone Kits ICZ-101-LF-25 1 3.716 <br /> 6 Control/Zone Hunter Industries R ICV ICV-101G 1 1.5 Drawn By: <br /> - 7 Control/Zone Hunter Industries R ICV ICV-101G 1 2.5 # NAME DATE <br /> 8 Zone Kit Hunter Industries R Drip Control Zone Kits ICZ-101-LF-25 1 7.063 T. Slininger 12/2020 <br /> Master Buckner-Superior 300 1-1/4' 3000 Master Vavle 1 0 <br /> Isolation/Shut Off Nibco T-113 1 0 <br /> ©2015 Kiesel Landscape Architecture Inc:The design ideas <br /> / <br /> and plans represented by these documents are the property <br /> i <br /> / I of Kiesel Design.Use or copy is permitted by contract only. <br /> I / \ The use or revisions of these ideas or plans is prohibited <br /> 1 // N, \IN, <br /> / I without the written permission of Kiesel Design. <br /> III o I I (POTABLE Title: <br /> - - - - - WATER) <br /> IIIallI o- -- <br /> I _ _ _ _ LOCATE P.O.C. EQUIPMENT IN IRRIGATION BACKFLOW DEVICE: Irrigation Plan <br /> .. .. .. .. . .. .. .. .. .. .. .. ..._..._..._..._..._..._..._..._..._.._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._.._..._..._..._..._..._..._..._..._..._... .._.. ..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._..._... PLANTING AREA, CONFIRM FINAL COORDINATE PRECISE LOCATION OF <br /> - - - - - - - - - - - - - - - - - - - - - - <br /> \ / LOCATION WITH THE OWNER OR BACKFLOW DEVICE WITH OWNER OR <br /> OWNER'S AUTHORIZED OWNER'S AUTHORIZED <br /> \ i REPRESENTATIVE PRIOR TO REPRESENTATIVE PRIOR TO <br /> \ / CONSTRUCTION. CONSTRUCTION. <br /> \ 0 8 16 24 FT Sheet Number: <br /> � I <br /> Scale: 1/16" = 11-011 <br /> L2ml <br />