Laserfiche WebLink
DIVISION 6 - WOOD SECTION 07 54 00 - THERMOPLASTIC MEMBRANE ROOFING ` x CD T <br /> N Cy') <br /> SECTION 06 20 00 - FINISH CARPENTRY o LO � <br /> SECTION 05 40 00 - COLD FORMED METAL FRAMING SECTION 06 10 00 - ROUGH CARPENTRY <br /> N <br /> PRODUCT: FIRESTONE ULTRA PLY TPO ROOFING SYSTEM, MECHANICALLY ~ >< <br /> PRODUCTS: TONGUE & GROOVE WOOD PANELLING AND TRIM BY CENTRAL ATTACHED (45 MIL). COLOR: WHITE x o o <br /> METAL STUD FRAMING; IN ACCORDANCE WITH AISI-S100/S-200. PRODUCTS: WOOD FRAMING, WOOD SUPPORTS, WOOD BLOCKING, WOOD HARDWOODS. REFER TO FINISH SCHEDULE FOR SPECIES, GRADE, AND FINISH - W Q E <br /> NAILERS, WOOD FURRING, WOOD SHEATHING & BUILDING WRAP <br /> SCUPPER FLASHING: FIRESTONE TPO SCUPPER (LATERAL DRAIN), SIZED PER ROOF <br /> 1. ALL FINISH CARPENTRY PRODUCTS SHALL BE KILN-DRIED TO A MAXIMUM MOISTURE DETAILS, VIA FIRESTONE ULTRAPLY TPO CUSTOM ACCESSORY QUOTE FORM L7 C" o <br /> 1. WORK INCLUDES LIGHT-FRAME NON-STRUCTURAL CONSTRUCTION. WHEN METAL o 0 <br /> STUDS ARE UNDER A LOAD GREATER THAN 5 PSF, THE GC IS REQUIRED TO 1. FRAMING LUMBER: AMERICAN SOFTWOOD LUMBER STANDARDS PS20, S4S, 19% CONTENT OF 9%. C <br /> VIA o M <br /> FIRESTONE 4X4 SQUARE TUBE BOOT, o <br /> PROVIDE ENGINEERING SHOP DRAWINGS TO ARCHITECT AND OWNER FOR MAXIMUM MOISTURE CONTENT WITH THE FOLLOWING MINIMUM WORKING ROOF SCREEN COLUMN FLASHING BOOT: V _= � <br /> APPROVAL. STRESSES: 2. DO NOT DELIVER OR INSTALL INTERIOR FINISH CARPENTRY MATERIALS UNTIL FIRESTONE ULTRAPLY TPO CUSTOM ACCESSORY QUOTE FORM C/) <br /> ti <br /> BUILDING IS ENCLOSED AND WEATHERPROOF, WET WORK IN SPACE IS COMPLETED o ti <br /> 2. PROTECT METAL STUDS FROM RUSTING OR DAMAGE DURING DELIVERY, STORAGE BENDING (fB) = 1,500 PSI AND NOMINALLY DRY, AND HVAC SYSTEM IS OPERATING AND MAINTAINING 1. RIGID ROOF INSULATION: REFER TO SECTION 07 22 00 0 <br /> & ERECTION. COATINGS: G60, A60, AZ50, GF30 FOR STRUCTURAL, G40 HORIZONTAL SHEAR (fV) = 95 PSI TEMPERATURE AND RELATIVE HUMIDITY AT OCCUPANCY LEVELS DURING THE <br /> NON-STRUCTURAL. COMPRESSION PERPENDICULAR TO GRAIN (fC) = 390 PSI REMAINDER OF THE CONSTRUCTION PERIOD. DO NOT INSTALL FINISH CARPENTRY 2. ALL ACCESSORIES, FLASHING, CORNERS, ADHESIVE, FASTENERS, <br /> MODULUS OF ELASTICITY (E) = 1,500,000 MATERIALS THAT ARE WET, MOISTURE DAMAGED, OR MOLD DAMAGED. CAULKING, ETC. SHALL BE AS FURNISHED OR APPROVED BY ROOF <br /> 3. THICKNESS; MIN. 0.0329" STRUCTURAL; 0.0179" NON-STRUCTURAL MANUFACTURER <br /> MEMBERS IN CONTACT WITH CONCRETE, MASONRY OR ROOF SHALL BE 3. NAILS: SIZE & TYPE TO SUIT APPLICATION, <br /> PRESERVATIVE TREATED, AWPB LP-2. 3. THE COMPLETE ROOF SYSTEM SHALL BE INSTALLED IN STRICT <br /> SECTION 05 50 00 - METAL FABRICATIONS 4. FINISH WOODWORK SHALL BE SET STRAIGHT, PLUMB OR LEVEL, CLOSELY FITTED ACCORDANCE WITH THE FIRESTONE ROOFING SYSTEMS APPLICATION <br /> FIRE RETARDANT TREATED LUMBER: AWPA C20 AND RIGIDLY FASTENED. JOINTS SHALL BE TIGHT AND FORMED TO CONCEAL GUIDE AND ANY OTHER APPLICABLE MANUFACTURER INSTRUCTIONS <br /> PRODUCTS: LOOSE STEEL LINTELS, PIPE BOLLARDS, MISC STEEL FRAMING & SHRINKAGE WITH A MAXIMUM GAP OF 1/8". END-JOINT SPACING SHALL BE RANDOM. AND ONLY BY A MANUFACTURER APPROVED INSTALLER WITH AT LEAST Store: Q <br /> SUPPORTS 2. PLYWOOD : PS1, FACTORY MARKED WITH APPROPRIATE APA TRADEMARK. INTERIOR CORNERS SHALL BE MITERED. 5-YEARS EXPERIENCE IN NEW COMMERCIAL MEMBRANE ROOFING. W KETTLEMAN & LOWER SCRAMENTO <br /> PROTECT ALL PLYWOOD FROM MOISTURE DURING INSTALLATION PROCESS. 5 4. AT ALL TIMES (EVERY DAY)AND AT THE COMPLETION OF THE WORK, <br /> STEEL PLATES, SHAPES & BARS: ASTM-A36 ROOF DECKING : APA RATED SHEATHING; 3/4" TONGUE & GROOVE PLYWOOD READY TORECEIVE <br /> FIELD APPLIED I FASTENERS, PUTTY & SAND SMOOTH FINISH. REMOVE ALL UNUSED MATERIAL AND DEBRIS FROM THE ROOF SURFACE LODI, CA 95242 <br /> STEEL TUBE: ASTM-A500 DECK (CDX), OR OTHER AS SHOWN ON DRAWINGS AND SITE. Restaurant #RC576 <br /> 6. WOOD DOORS: INSTALL WOOD DOORS PLUMB, TRUE & FITTED PROPERLY. NEATLY <br /> STEEL PIPE: ASTM-A53 (SCHEDULE 40) WALL SHEATHING (EXT APA RATED SHEATHING; 5/8", EXPOSURE 1 MORTISE, DRILL &ANCHOR ALL HARDWARE. 5. ROOFING AND FLASHING SPECIFIED HEREIN SHALL BE COMPLETE IN P4E-HV-M SCHEME A <br /> EVERY RESPECT AND 100% WATER &WEATHER TIGHT. <br /> BOLTS, NUTS & WASHERS: ASTM-A307 WALL SHEATHING (INTX APA RATED SHEATHING; 1/2" CDX Professional of Record: JEFF LIEDERMAN <br /> 6. THE ROOFING CONTRACTOR SHALL FURNISH TO THE OWNER THE <br /> PRIMER FOR FERROUS METALS: SSPC-PAINT 20 SUBSTITUTION OF OSB FOR PLYWOOD SHEATHING SHALL BE AT THE DISCRETION MANUFACTURER'S STANDARD TEN (10) YEAR WARRANTY (PAID FOR BY <br /> OF THE OWNER C.M. CONTRACTOR). THIS GUARANTEE SHALL COVER BOTH LABOR & <br /> 1. FABRICATION: VERIFY DIMENSIONS IN FIELD PRIOR TO FABRICATION. FABRICATE DIVISION 7 - THERMAL & MOISTURE PROTECTION MATERIALS NECESSARY TO RESTORE WATER TIGHTNESS. IN ADDITION, <br /> ITEMS W/JOINTS TIGHTLY FITTED / SECURED. FIT & SHOP ASSEMBLE IN LARGEST 3. NAILS, SPIKES & STAPLES: GALVANIZED FOR EXTERIOR LOCATIONS AND TREATED THE ROOFING CONTRACTOR WILL BE HELD RESPONSIBLE FOR DAMAGES FvAA <br /> PRACTICAL SECTIONS FOR DELIVERY TO SITE. WOOD; PLAIN FINISH FOR OTHER INTERIOR LOCATIONS; SIZE & TYPE TO SUIT CAUSED BY FAULTY INSTALLATION. IN ADDITION TO MANUFACTURER'S DESIGN <br /> APPLICATION. WARRANTY, THE ROOFING CONTRACTOR SHALL FURNISH GUARANTEE <br /> 2. PRIME ITEMS TO PROVIDE UNIFORM, DRY FILM THICKNESS OF 2.0 MILS. COVERING WATER TIGHTNESS OF THE COMPLETE ROOFING SYSTEM / <br /> 4. BOLTS, NUTS, WASHERS, LAGS, PINS & SCREWS: MEDIUM CARBON STEEL, SIZED SECTION 07 21 16 - BATT INSULATION INSTALLATION FOR A PERIOD OF ONE (1)YEAR FROM THE DATE OF <br /> TO SUIT APPLICATION; GALVANIZED FOR EXTERIOR LOCATIONS, PLAIN FINISH FOR SUBSTANTIAL COMPLETION. A r c h i t e C t u r a <br /> SECTION 05 51 33 - METAL LADDERS INTERIOR. PRODUCT: UNFACED BATT INSULATION; 6", BY CERTAINTEED CORPORATION, OR Solutions Group <br /> APPROVED EQUAL. 7. THE RETAINAGE FOR THE ROOFING WORK WILL NOT BE PAID UNTIL THE 1 101 Central Expressway South <br /> PRODUCTS: ALUMINUM LADDERS BY CARBIS, INC 6. COMPLY WITH NFPA NATIONAL DESIGN SPECIFICATION FOR WOOD WARRANTIES ARE PROVIDED. Suite 100 <br /> CONSTRUCTION RECOMMENDATIONS FOR SIZE AND SPACING OF MEMBERS, IF WALL CAVITY INSULATION: R VALUE = R-19. Allen, TX 75013 <br /> LADDERS, FIXED, SAFETY REQUIREMENTS: ANSI A14.3 SPECIFIC SIZES ARE NOT INDICATED. ERECT ALL MEMBERS TRUE TO LINES & CONTACT: EVERETT FIELDS <br /> LEVEL. (469) 619-1164 <br /> ALUMINUM &ALUMINUM-ALLOY SHEET & PLATE: ASTM B209 1. INSTALLATION & ACCESSORIES AS RECOMMENDED BY INSULATION SECTION 07 61 13 - STANDING SEAM SHEET METAL ROOFING EFIELDS@PMDGINC.COM <br /> 7. PROVIDE BLOCKING AS REQUIRED FOR SUPPORT OF ALL WALL MOUNTED MANUFACTURER FOR TYPE OF APPLICATION. <br /> ALUMINUM-ALLOY EXTRUDED BAR, ROD, WIRE, SHAPE, & TUBE: ASTM B211 CABINETWORK & TABLES, SUSPENDED SHELVING, CEILING CANOPIES, SPEAKERS, PRODUCT: STANDING SEAM METAL ROOF PANELS BY BERRIDGE MANUFACTURING <br /> HARDWARE, TOILET PARTITIONS, ACCESS LADDER, ACCESSORIES, AND PLUMBING 2. PLACE BATT INSULATION IN PARTITIONS TIGHT WITHIN SPACES, AROUND CUT COMPANY <br /> QUALITY MANAGEMENT SYSTEMS REQUIREMENTS: ISO 9001:2000 FIXTURES. OPENINGS, BEHIND AND AROUND ELECTRICAL & MECHANICAL ITEMS WITHIN OR <br /> BEHIND PARTITIONS AND TIGHT TO ITEMS PASSING THROUGH PARTITIONS. STANDING SEAM PANELS: TEE-LOCK PANEL <br /> 1. MATERIALS: ASTM B221, ALLOY 6063, TEMPER T-6, NON-SPARK EXTRUDED 8. DO NOT SPLICE STRUCTURAL MEMBERS BETWEEN SUPPORTS. <br /> ALUMINUM AND ASTM B209, ALLOY 6063 TERMPER T-6 SHEET ALUMINUM. MILL THICKNESS: 24 GAUGE �o AR F! T� <br /> FINISH. 9. PROVIDE EPDM SILL GASKET AT ALL EXTERIOR WALLS. GASKET MUST EXTEND COLOR: REFER TO SCHEDULE OF EXTERIOR MATERIALS <br /> ACROSS ENTIRE WIDTH OF SILL PLATE AND BOTTOM EDGE OF WALL SHEATHING RM <br /> 2. NOMINAL HEIGHT AS INDICATED ON THE DRAWINGS. SUCH THAT THERE IS NO DIRECT CONTACT BETWEEN WOOD AND CONCRETE. SECTION 07 22 00 - RIGID ROOF & DECK INSULATION FINISH: PRE-FINISHED KYNAR 500 c-29534 <br /> 3. WALL BRACKETS: 2 INCH BY 1/4 INCH MINIMUM FLAT BAR ALUMINUM WALL PRODUCT: ISO 95+ GL POLYISOCYAN U RATE BOARD BY FIRESTONE 30, 202 <br /> BRACKET. WEATHER RESISTANT BARRIER: GRACE ICE AND WATER SHIELD sT PR N�50s 9PSE�o� <br /> SECTION 06 16 00 - CEMENT BOARD COVER BOARD: ISOGARD HD BY FIRESTONE 1. ALL METAL PANEL ROOFING, FLASHING & TRIM SHOULD HAVE A 20-YEAR "FINISH" 9TF of CPQ\ <br /> 4. SIDE RAILS: 1-1/2 INCHES WIDE BY 3 INCH TUBES WITH 1/8 INCH WALL THICKNESS. GUARANTEE AGAINST CRACKING, PEELING & FADE. <br /> PRODUCTS: DUROCK BY USG, 1/2" THICKNESS, OR APPROVED EQUAL R-VALUE: R-24 <br /> 5. SAFETY POSTS: BILCO LU-4 LADDER UP SAFETY POST, BOTH SIDES 2. INSTALLER SHALL FURNISH GUARANTEE COVERING WATER TIGHTNESS OF THE <br /> MECHANICALLY ATTACH AND TAPER WHERE REQUIRED TO FACILITATE DRAINAGE. <br /> 6. RUNGS: 1-1/4 INCH O.D. TUBE WITH RIBBED SURFACE AND CAPABLE OF 1,000 METAL ROOFING SYSTEM FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF <br /> POUND LOAD. SPACE 12 INCHES ON CENTER. ATTACH RUNGS IN CENTERLINE OF SUBSTANTIAL COMPLETION. <br /> SIDE RAILS BY WELDING. SECTION 06 17 53 - SHOP-FABRICATED WOOD TRUSSES 3. COMPLY WITH MANUFACTURERS STANDARD INSTRUCTIONS AND CONFORM TO Prototype : P4E- HV 2020 -2.0 RELEASE <br /> 7. RUNG LENGTH: 24 INCHES. PRODUCT: PREFABRICATED METAL CONNECTED WOOD TRUSSES, SIZE & SPACING SECTION 07 22 20 - FIBERGLASS REINFORCED GYPSUM ROOF BOARD STANDARDS SET FORTH IN THE ARCHITECTURAL SHEET METAL MANUAL PUBLISHED Prototype Issue Date: 7.14.2020 <br /> AS INDICATED ON DRAWINGS. BY SMACNA IN ORDER TO ACHIEVE A WATER TIGHT INSTALLATION. <br /> 8. DO NOT BEGIN INSTALLATION UNTIL SUBSTRATES HAVE BEEN PROPERLY PRODUCT: PRODUCT: FIRE-RATED FIBERGLASS-MAT FACED, MOISTURE AND MOLD Design Bulletin Updates: -- <br /> PREPARED. NOTIFY OWNER/ARCHITECT OF UNSATISFACTORY CONDITIONS 1. DESIGN REQUIREMENTS: RESISTANT GYPSUM ROOF BOARDS. G-P DENSDECK, USG SECUROCK, OR 4. SUBSTRATE: PRIOR TO INSTALLATION OF ANY METAL PANELING, THE ROOFING <br /> BEFORE COMMENCING WORK. FIELD VERIFY REQUIRED DIMENSIONS. TRUSS DESIGN STANDARD: DESIGN SPECIFICATION FOR METAL CONNECTED APPROVED EQUAL. <br /> CONTRACTOR IS REQUIRED TO INSPECT THE ROOF SUBSTRATE FOR ACCEPTANCE Date Issued: Bulletin Number: <br /> COORDINATE WITH SUPPORTING CONSTRUCTION TO ENSURE ADEQUATE WOOD TRUSSES PUBLISHED BY TRUSS PLATE INSTITUTE (TPI). WOOD AND NOTIFY GENERAL CONTRACTOR OF ANY ISSUES IN WRITING BEFORE <br /> BLOCKING AND SUPPORT. STRUCTURAL DESIGN STANDARD: NATIONAL DESIGN SPECIFICATION FOR WOOD INSTALLED OVER RIBBED STEEL DECK PROCEEDING. <br /> UBLISHED BY N.F.P.A. <br /> UCTION <br /> 9. INSTALL LADDERS AND ACCESSORIES IN ACCORDANCE WITH MANUFACTURER'S TRUSSRFABRICA TON STANDARD QUALITY CONTROL MANUAL PUBLISHED BY TPI. THICKNESS: 1/2" c 1ST BLDG. SUBMITTAL <br /> 5. WEATHER BARRIER MEMBRANE SHALL BE INSTALLED HORIZONTALLY STARTING <br /> INSTRUCTIONS AND APPROVED SUBMITTALS. SECURELY ANCHOR SUPPORT GRADED LUMBER: PROVIDE ONLY LUMBER GRADED BY A RECOGNIZED AGENCY EAVE TO RIDGE) WITH A 6" MINIMUM OVERLAP AND 18-INCH MINIMUM ENDLAPS. <br /> BRACKETS WITH FASTENERS OF TYPE AND SIZE RECOMMENDED BY COMPLYING WITH REQUIREMENTS OF AMERICAN LUMBER STANDARDS SCREWS: ASTM C1002, CORROSION RESISTANT TREATED. <br /> MANUFACTURER. PLACE BRACKETS STARTING AT TOP 1 FOOT DOWN FROM TOP COMMITTEE. 6. WHEN NECESSARY, PANELS SHALL BE SITE-FORMED WITH BERRIDGE APPROVED <br /> OF PARAPET WALL. ALLOW CONTINUOUS BRACKET SPACING ON CENTER POINTS LUMBER: PROVIDE KILN DRIED LUMBER WITH 15% MAXIMUM MOISTURE CONTENT 1. ALL COMPONENTS USED IN ROOFING SYSTEMS SHALL BE PROTECTED FROM PORTABLE ROLL FORMER IN CONTINUOUS LENGTHS. <br /> OF 48 INCHES DOWN FROM TOP BRACKET. PROVIDE A MINIMUM CLEARANCE OF 7 AT TIME OF DRESSING. EXPOSURE TO MOISTURE BEFORE, DURING AND AFTER INSTALLATION. <br /> INCHES FROM WALL SURFACE TO CENTER LINE OF RUNGS. INSPECT LADDER TO SPECIES: SOUTHERN PINE; SPIB GRADE: MSR2400 FOR TOP & BOTTOM CHORD <br /> VERIFY PROPER AND SECURE INSTALLATION. MEMBERS; SPIB GRADE: NO.2 FOR WEB MEMBERS. 2. REMOVE ANY PLASTIC PACKAGING FROM ROOF BOARDS IMMEDIATELY UPON <br /> SUBSTITUTION OF DOUGLAS FIR OR HEMLOCK OF EQUIVALENT STRUCTURAL RECEIPT OF DELIVERY. FAILURE TO REMOVE PLASTIC PACKAGING MAY RESULT IN SECTION 07 62 00 - SHEET METAL FLASHING & TRIM <br /> RATING SHALL BE AT THE DISCRETION OF THE OWNER C.M. ENTRAPMENT OF CONDENSATION OR MOISTURE, WHICH MAY CAUSE APPLICATION <br /> METAL CONNECTOR PLATES: GALVANIZED SHEET STEEL: ASTM A446, GRADE A, PROBLEMS THAT ARE NOT THE RESPONSIBILITY OF MANUFACTURER. ANY PRODUCT: SHEET METAL FLASHING & TRIM, METAL COPING, GUTTERS & <br /> DOWNSPOUTS. REVISIONS: <br /> 10. CLEAN LADDER AS RECOMMENDED BY MANUFACTURER. DO NOT USE ABRASIVE COATING G60 (NOT LESS THAN 0.36" THICK). PROTECTIVE, PLASTIC FACTORY PACKAGING THAT IS USED TO WRAP ROOF <br /> AGENTS, STEEL WOOL OR CHEMICALS. BOARDS FOR SHIPMENT IS INTENDED TO PROVIDE TEMPORARY PROTECTION FROM 12.22.2020 1st Building Submittal <br /> 2. PRODUCT DATA: SUBMIT FABRICATORS SPECIFICATIONS AND INSTALLATION MOISTURE EXPOSURE DURING TRANSIT ONLY AND IS NOT INTENDED TO PROVIDE SHEET MATERIAL SUPPLIED BY BERRIDGE MANUFACTURING COMPANY; 1 <br /> INSTRUCTIONS FOR REQUIRED WORK COVERING LUMBER, METAL PLATES, PROTECTION DURING STORAGE AFTER DELIVERY. PRE-FINISHED GALVANIZED SHEET STEEL WITH KYNAR 500 FINISH (24 GA.); 2 <br /> HARDWARE, FABRICATIONS PROCESS, HANDLING & ERECTION. SUBMIT REFER TO FINISH SCHEDULE FOR COLOR 3 <br /> CERTIFICATION INDICATING THAT TRUSSES SUPPLIED FOR PROJECT COMPLY 3. ROOF BOARDS STORED OUTSIDE SHALL BE STORED LEVEL AND OFF THE GROUND 4 <br /> WITH INDICATED REQUIREMENTS. AND PROTECTED BY A WATERPROOF COVERING. PROVIDE MEANS FOR AIR 1. COMPLY WITH MANUFACTURERS STANDARD INSTRUCTIONS AND CONFORM <br /> CIRCULATION AROUND AND UNDER STORED BUNDLES OF ROOF BOARDS. USE TO STANDARDS SET FORTH IN THE ARCHITECTURAL SHEET METAL MANUAL 5 <br /> 3. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS SHOWING SPECIES, SIZE, DIMENSIONS ADEQUATE SUPPORTS TO KEEP THE BUNDLES FLAT, LEVEL AND DRY. PUBLISHED BY SMACNA IN ORDER TO ACHIEVE A WATER TIGHT 6 <br /> AND STRESS GRADES OF LUMBER TO BE USED; SPAN, CAMBER CONFIGURATION INSTALLATION. 7 <br /> AND SPACING FOR EACH TYPE OF REQUIRED TRUSS. FABRICATOR SHALL SUBMIT 4. INSPECTION: VERIFY THAT PROJECT CONDITIONS AND SUBSTRATES ARE 8 <br /> DESIGN ANALYSIS CALCULATIONS INCLUDING LOADING, SECTION MODULUS, ACCEPTABLE TO THE INSTALLER TO BEGIN INSTALLATION OF WORK OF THIS 2. FASTENERS: SAME METAL AS FLASHING / SHEET METAL OR OTHER NON-CORROSIVE <br /> ASSUMED ALLOWABLE STRESS AND SIMILAR INFORMATION NEEDED FOR SECTION. METAL AS RECOMMENDED BY THE SHEET METAL MANUFACTURER. MATCH FINISH <br /> ANALYSIS. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A STRUCTURAL OF EXPOSED HEADS TO MATERIAL BEING FASTENED. <br /> ENGINEER LICENSED TO PRACTICE IN THE STATE WHERE TRUSSES ARE TO BE 5. CARE SHOULD BE TAKEN DURING INSTALLATION TO AVOID THE ACCUMULATION OF <br /> ERECTED. MOISTURE IN THE SYSTEM. ROOF BOARDS SHALL BE COVERED THE SAME DAY AS <br /> 3. SHOP FABRICATE ITEMS TO GREATEST EXTENT POSSIBLE. FORM WORK TO FIT Sheet Title: <br /> INSTALLED. SUBSTRATES. FORM EXPOSED SHEET METAL WORK WITHOUT EXCESSIVE "OIL <br /> 4. HANDLE & STORE TRUSSES WITH CARE AND IN ACCORDANCE WITH EDGESFOLDEDKBACK TOFORMMARKS, TRUE TO LINE AND LEVELS WITH EXPOSED PROJECT <br /> MANUFACTURERS INSTRUCTIONS AND TPI RECOMMENDATIONS TO AVOID 6. AVOID APPLICATION OF ROOF BOARDS DURING RAIN, HEAVY FOG AND ANY OTHER <br /> DAMAGE. CONDITIONS THAT MAY DEPOSIT MOISTURE ON THE SURFACE, AND AVOID THE OVERUSE OF NON-VENTED, DIRECT-FIRED HEATERS DURING WINTER MONTHS. SPECIFICATIONS <br /> 4. THE FACE OF THE PRE-FINISHED METAL CAP FLASHING OR ROOF COPING SHOULD <br /> 5. FASTENERS & ANCHORAGE: PROVIDE SIZE, TYPE, MATERIALS AND FINISH AS BE 4-INCHES HIGH FROM THE TOP OF THE BREAK TO THE DRIP TO ACCEPT THE LED Date: 12.21.2020 <br /> INDICATED COMPLYING WITH APPLICABLE FEDERAL SPECIFICATIONS FOR NAILS, 7. PROTECT GYPSUM BOARD INSTALLATIONS FROM DAMAGE AND DETERIORATION CHANNEL. <br /> SCREWS, BOLTS, NUTS & WASHERS AND ALL ANCHORING DEVICES. UNTIL DATE OF SUBSTANTIAL COMPLETION. Project Number: RAC19048.0 <br /> 5. ALL EXPOSED ADJACENT FLASHING MUST BE OF THE SAME MATERIAL AS THE FINISH <br /> 6. ERECT TRUSSES WITH PLANE OF TRUSS WEBS VERTICAL AND PARALLEL TO EACH PANELS. Drawn By: _ <br /> OTHER LOCATED ACCURATELY (SPACING AS INDICATED). ANCHOR TRUSSES SECTION 07 25 00 - WEATHER BARRIERS <br /> SECURELY AT ALL BEARING POINTS. DO NOT CUT TRUSS MEMBERS. 6. REPLACE ALL DAMAGED OR SCRATCHED PANELS, FLASHING OR TRIM. <br /> EXTERIOR MASONRY WALLS: GRACE ICE & WATER SHIELD <br /> EXTERIOR STUCCO WALLS: 2 LAYERS 30# FELT Sheet Number: <br /> A9 . 30 N <br /> J <br /> Q <br /> H <br /> H <br /> L <br /> m <br /> C/7 <br />