MAKING DRAIN CONNECTIONS (SEE FIGURE 5) faucet OPEN to a minimum of 0.5 GPM for the unit to operate. <br /> A. Drain connections are made at the front of the water heater. Refer If the burner does not light, the system will automatically attempt <br /> to Figure 5. Connect 5/8" ID hose to system drain fitting provided two more tries for ignition before lock-out. When light remains <br /> on front of unit. Connect I/V ID hose to condensation drain fitting illuminated,the system is in lockout. <br /> provided on front of unit. 8. If lockout occurs, unit must be re-cycled by turning the faucet OFF <br /> B. Drain lines must run to the outside of the RV. Drain lines should be or turning the switch OFF and then back ON. The first start-up <br /> as short as possible and must maintain a minimum drop of Y:' per of the heater may require several ignition cycles before all air is <br /> foot. (6.4mm per 305mm). See Figure 5. purged from the gas lines. <br /> This On Demand Water Heater is factory set at 49°C/120°F. To change <br /> MAKING WATER CONNECTIONS (SEE FIGURE 5) the water temperature settings, you will need to access the front of the <br /> A. Water connections are made at the front of the water heater. Refer water heater. <br /> to Figure 5. Connect the hot and cold water lines to the 1/2" NPT 1. Remove the SERVICE PANEL as shown in Figure 9. <br /> female pipe fittings provided on front of unit. These fittings are 2. Locate the set offour(4)dip switches located onthe module board <br /> marked"HOT"and"COLD". and refer to Figure 12 for information on setting dip switches to <br /> IMPORTANT:Use a pipe thread compound suitable for potable water or desired temperature setting. <br /> pipe thread tape on all connections to ensure they will not leak. <br /> B. For ease of removal, it is suggested that a pipe union be installed OPERATING INSTRUCTIONS WITH OPTIONAL <br /> in each water line. ON DEMAND CONTROL CENTER (SEE FIGURE 13) <br /> C. Fill system with water. Open both hot and cold water faucets to 1. STOP! Read the safety information provided in the Operation <br /> expel air from system. When system is filled and water flows from Manual that came with your unit. <br /> faucets, close both faucets and check all connections for leaks. 2. Turn off all electric power to the appliance. <br /> 3. Tum"OFF"gas supply. <br /> MAKING GAS CONNECTIONS 4. Wait five minutes for gas to clear the area. If you smell gas then <br /> A. Connect a 3/8"gas supply line to the 3/8"flare fitting at gas valve. STOP!Follow instructions in item B ofthe SAFETY INFORMATION <br /> When making the gas connection, hold the gas fitting on the valve provided in the Operation Manual that came with your unit. If you <br /> with a wrench when tightening the flare nut. Failure to hold fitting do not smell gas, go to next step. <br /> securely could result in a gas leak due to fitting being damaged. 5. Turn"ON"gas supply. <br /> B. Tum on gas and check all fittings and connections for leaks using a 6. Tum on electrical power to the appliance. <br /> soap and water solution.Correct even the slightest leak immediately. 7. PRESS THE "ON" button. The On Demand Control Center is <br /> NOTE: When replacing your water heater with an NAUTILUS (IW60) illustrated in Figure 13. Your On Demand Control Center is located <br /> On Demand water heater, review your gas regulator to ensure it can somewhere inside the RV. The water heater operates based off of <br /> maintain a proper gas flow during the operation of the On Demand "flow." There must be a hot water faucet OPEN to a minimum of 0.5 <br /> water heater and other gas burning appliances. GPM for the unit to operate. If the burner does not light, the system <br /> NOTE: Regulator switch over pressure may be lower than main will automatically attempt two more tries for ignition before lock-out. <br /> operating pressure. 8. If lockout occurs, an ERROR CODE will be displayed on the On <br /> Maximum Capacity of Pipe in Cubic Feet - "I Pressures Demand Control Center and the unit must be re-cycled by turning the <br /> PSIG or Less and a Pressure Drop• faucet OFF or by pressing the OFF button on the On Demand Control <br /> INTENDED USE Center and then back ON. The first start-up of the heater may require <br /> T""'ns In.a ba." .,.,w.,a n°"'s'an"p-ral egu1torn°'"""""`° several ignition cycles before all air is purged from the gas lines. <br /> Nominal: K 8 L: 1/4 3/e 1/2 5/8 This On Demand Water Heater is factory set at 49'C/1 20'F. To change <br /> Nominal: ACR: 3/8 1/2 518 3/4 the water temperature settings: <br /> Outside Diameter. 0.375 0.500 0.625 0.750 1. Press the UP or DOWN arrows on the On Demand Control <br /> Inside Diameter- 0.305 0.402 0.527 0.652 Center to increase or decrease the SET water temperature in <br /> single degree increments. The water temperature set range is <br /> Length(feet) Capacity in Thousands of BTU per Hour 35'C/95°F to 54°C/130°F. See Figure 13. <br /> 10 45 93 188 329 <br /> 20 31 64 129 226 OPERATING FAUCETS AND SHOWER WITH THE <br /> 30 25 51 104 182 NAUTILUS (IW60) ON DEMAND WATER HEATER <br /> 40 21 44 89 155 A. All faucets must be operated the same as you would in your home. <br /> B. Unit thermostat is set at 120"F at the factory. Cold water must be <br /> so 1s 3s 7e 138 added to achieve the desired hot water temperature. <br /> *Table capacities are based on TYPE K copper tubing I.D. 1. If this is the first use of the unit for the season, turn water <br /> supply on and open each faucet and allow all air to be purged <br /> OPERATING INSTRUCTIONS WITH SWITCH AND from the water lines. <br /> LIGHT ASSEMBLY (SEE FIGURE 12) 2. Turn ON power supply. <br /> 1. STOP! Read the safety information provided in the Operation 3. Turn ON propane supply. Hot water faucet may have to be <br /> Manual that came with your unit. cycled several times to purge gas supply. <br /> 2. Turn off all electric power to the appliance. C. The water heater only heats when there is a call for water(open hot <br /> 3. Turn"OFF"gas supply. water faucet). <br /> 4. Wait five minutes for gas to clear the area. If you smell gas then D. A minimum of 0.5 gallons per minute is required forwater heater <br /> STOP! Follow instructions in item B of the OPERATING SAFETY to operate. <br /> INFORMATION provided in the Operation Manual that came with E. Faucet should be turned on and adjusted to desired temperature <br /> your unit. If you do not smell gas,go to next step. and flow before entering shower. <br /> 5. Turn"ON"gas supply. F. Shower head button should NOT be used. Using the shower head <br /> 6. Turn on electrical power to the appliance. button will create a drop in temperature by reducing or stopping the <br /> 7. Turn switch that operates the water heater to "ON" position. The flow of water through the water heater causing the water heater to <br /> switch is illustrated in Figure 12. Your Switch may be different in shut down. <br /> appearance and is located somewhere inside the RV The water G. Flow restrictors in faucets and shower heads should be removed <br /> heater operates based off of"flow." There must be a hot water for best performance. <br /> 5 <br />