Laserfiche WebLink
5" EXTEND FACE OF ALUM <br /> ANGLE FOR CAULK& CORTEN T-GROOVE DOUBLE TOP <br /> 311 lot IF� BACKER ROD METAL WALL PANEL PLATES SEE SECTION J/A5.5 <br /> Z-METAL TRIM PARAPET CAP FOR FRAMINGIT 1 <br /> END DAM @ OUTSIDE CORNER FASTENER AT CONTINUOUS FASTENER AT <br /> WINDOW BOT. Z-METAL TRIM-SMALL <br /> 12"O.C. CLEAT 1/4"SLOPE 12"O.C. <br /> 2ND SURFACE TRACK 1 POP RIVET OR FASTENER #12X1 FASTENER AT <br /> WATER - - - - - <br /> BUTYL FLASHING PROOFING 795 DOW CORNING A6.2 W/NEOPRENE WASHER 12"O.C. <br /> APPLIED OVER SILICONE (OR EO.) <br /> AT 12"O.C. MAX CORTEN T-GROOVE 1 <br /> TAPE AT TOP OF <br /> LU BLDG PAPER STUDS & OVER LAG BOLT/ T.O. TOWER PARAPET CONTINUOUS BUTYL I , <br /> Z WASHER THRU — — SEALANT BEAD I METAL WALL PANEL i <br /> o PLYWD 26-011 (N)EXTERIOR , <br /> U) BOT. TRACK (TYP) & BEAD BETWEEN I TOWER WALL BLUESKIN VP WATER i 1 <br /> U) <br /> BUTYL FLASHING 2ND SURFACE FLASHING AND PANEL <br /> AT END DAM I BARRIER MEMBRANE RESISTIVE <br /> 1 <br /> TAPE APPLIED PLASTIC WATER 11 T-GROOVE PANEL �I <br /> w= PRIOR TO BLDG 3/8" PROOFING <br /> X? <br /> PAPER W/3" MIN. <br /> SPACER APPLIED OVER A6.2 BLUESKIN VP (E)EXTERIOR , <br /> o FLAP WATER RESISTIVE STUD WALL 1/2"PLYWOOD <br /> o Q SHIM STUDS & MEMBRANE IF�_ SHEATHING <br /> PLYWD <br /> SEE SECTION J/A5.5 <br /> 1/2"PLYWOOD <br /> w o 2ND SURFACE T.O. LOW PARAPET 0 SHEATHING ,, 4 ,, 8" (ORAS REQUIRED) FOR FRAMING <br /> LU WATER <br /> 20'-0" 2" Vmj architecture <br /> PROOFING 2 1/2 _ <br /> _� - COLOR o o Design - Planning - Interiors <br /> S o APPLIED OVER WINDOW BOT. � - w SIDE o - o f COLOR SIDE 637 5th Avenue San Rafael, CA 94901 <br /> C)m STUDS & TRACK (SILL 2„ _ ,M� �, �� ��` ,M� 415-451-2500 415-451-2595 fax <br /> Q PLYWD RECEPTOR) �,2" �, N \� 7 � j o00 <br /> LU o OJ www.vmarch.com <br /> o a 3/8" SPACE WOOD A6 2 Z-METAL TRIM(SMALL) Z-METAL TRIM OUTSIDE CORNER <br /> a o CONTINUOUS AROUND FRAMING SLOPE 1/4"PER FOOT \q;� VMI JOB NUMBER <br /> NOTE: WOOD SILLS WOOD ENTIRE WINDOW 20049 <br /> o E &JAMBS SHALL BE FRAMING PLYWOOD <br /> PRESSURE WEEP HOLES @ 24" O.C. WALL 5 OUTSIDE CORNER 11/2" = 11-0 <br /> " 5 PARAPET 1 1/2" = 1'-0' 1 <br /> z o TREATED PLYWOOD SHEATHING A6.2 <br /> o w WALL �,� AR <br /> SHEATHING FASTENER AT BLUESKIN VP �� <br /> o ADD SILL RECEPTOR AND END DAM <br /> 12"O.C. WATER RESISTIVE �,~ �NAR� <br /> om <br /> WATER PROOFING ROUGH OPENING CORTEN T-GROOVE AIR BARRIER <br /> U? THIS DIAGRAM SHOWS THE APPLICATION OF SILL RECEPTOR. I METAL WALL PANEL MEMBRANE x <br /> 0 2PUSE 100% PURE ISOPROPYL ALCOHOL TO CLEAN METAL CORTEN T-GROOVE No. C17928 <br /> CO AFTER FRAMING 2ND SURFACE WATER PROOFING PER STUCCO SURFACE PRIOR TO APPLYING SILICONE. METAL WALL PANEL I FASTENER AT 1 <br /> LL w MANUFACTURER. ADD FLASHING TAPE AROUND THE ROUGH OPENING FOR 2 I 12"O.C. I WOODcl) REN. 10/31/23 <br /> c!' <br /> THE WINDOW AND DOOR OPENING A6.2 FASTENER AT I TRANSITION/SILL TRIM I STUDS �� 01 <br /> >Q 12°O.C. I I 1 of CALZ� <br /> POP RIVET OR FASTENER <br /> U) TRANSITION/SILL TRIM LU doomI /NEOPRENE WASHER I I 5/8"GYPSUM <br /> �0- I AT 12"O.C. MAX. I BOARD <br /> NOTE: THERE I 6 <br /> o(.6 1 <br /> SHOULD BE A 3/8" A6.2 <br /> BLUESKIN VP WATER 1 <br /> 0 <br /> o SPACE AROUND RESISTIVE AIR I 1" <br /> LU <br /> EXTERIOR FINISH I THE ENTIRE F.F.E. — BARRIER MEMBRANE CONTINUOUS BUTYL <br /> J = WINDOW FRAME TO � off <br /> SEALANT BEAD <br /> ca ALLOW FORA I BEAD BETWEEN <br /> Z CONTINUOUS RING 1/2"PLYWOOD I FLASHING AND PANEL <br /> o SHEATHING <br /> CL <br /> OF BACKER ROD 3 <br /> o o AND CAULK SIMILAR I 1/2"PLYWOOD <br /> A6.2 SHEATHING w <br /> w TO A TYPICAL <br /> GLAZING SYSTEM GASKET ON A <br /> �o <br /> BOTTLE TOP. <br /> aZ <br /> WINDOW ELEVATION TRANSITION/SILL TRI <br /> w � <br /> CO Uj <br /> 00 <br /> REFRONT <br /> =o <br /> LU - WINODOW BODY FRONT ELEVATION 1/4" = 1'-0" 10 PANEL JOINT 6" = V-0° 6 VERTICAL PANEL JOINT 1 1/2" = 1'-0" 2 <br /> Q N o / CORTEN T GROOVE <br /> c� o 0 METAL WALL PANEL <br /> o> Z-CLIP SUPPORTS THE IN LIEU OF BATT INSULATION IN OUTER CELLS 1 1/ " <br /> 00 Q END OF THE METAL 177 <br /> BLUESKIN VP WATER RESISTEVE AIR COLOR SIDE <br /> N o PANEL I BARRIER MEMBRANE RECORD DATES <br /> I aw <br /> N o LL BLUESKIN VP <br /> CORTEN T-GROOVE <br /> � LL o WATER �T DD SUBMITTAL <br /> _ _ CORTEN T-GROOVE RESISTIVE AIR I METAL WALL PANEL BLDG.SUBMITTAL 2/4/2022 <br /> 0 _? — METAL WALL PANEL BARRIER _ — BID SET - <br /> 1/2"PLYWOOD <br /> =w I MEMBRANE SHEATHING FASTENER AT CONTRACT SET <br /> co §E E 12" MIN. <br /> cn =0 \ `— — 36"X24" WIDE SUMP SECTION I BLUESKIN VP FLASHING 1" Z-METAL TRIM SMALL 12"O.C. <br /> z 0_ \ X <br /> LU \ \ i WATER RESISTIVE CONTINUOUS POP RIVET OR FASTENER I REVISIONS <br /> LD o¢ \ \ ROOF PARAPET AIR BARRIER BUTYL W/NEOPRENE WASHER 10 2/1/2022 TB Corp Review <br /> Q Z o \ \ MEMBRANE SEALANT BEAD AT 12"O.C. MAX. <br /> \ \ BACKER ROD&CAULK ON TOP CONT. CANT STRIP, AND BEAD 1 0 <br /> o o \ \ OF SILL FLASHING SEE DETAIL 16/A6.0 — — — — — BETWEEN _ <br /> U o \ \ ROOF'G 0/ PLYWD. DECK PER J FLASHING AND ALTERNATE WALL TRIM 1 5/8"GYPSUM <br /> o o \ \ STRUCT. PLANS. 1/2"PLYWOOD CANOPY BASE TRIM 1 BOARD 0 = <br /> ROOF DRAIN SEE SHEATHING 1 0 <br /> vi o z \ RD 1/2" PLYWOOD <br /> w Q \ MFG. SPECS. GROUND/SLAB <br /> co >z \ \ 1 CORTEN T-GROOVE SHEATHING 1 FINISH 0 <br /> 0 C \ ROOF METAL WALL PANEL 2" iv <br /> o� \ FLOOR 0_ <br /> c�I >J \ \\ a�°oo°O OVERFLOW FLASHING WHIT - _if - <br /> N w o <br /> DRIP EDGE <br /> Q o \ - = .1¢ ' HEM <br /> a <br /> m ci \ <br /> w� \ 2 ?• CLIENT <br /> �o a m \ ALTER ATE 2J <br /> o c)T \ \ X Z METAL TRIM (SMALL) WALL TRIM PRB MANAGEMENT INC <br /> w� \ \ " I 4709 Mangels Blvd. <br /> � 44 <br /> ww <br /> am <br /> \ \ CORTEN T-GROOVE METAL PANEL 1 1/2" = 1' o" 11 ENLARGED CANOPY DETAIL 6" = 1'-o" 7 BASE TRIM HORIZONTAL 11/2" = V-0" $ Fairfield,CA 94534 <br /> \ \ 2X BLK'G. SITE#:3560 <br /> � U ZQ \ <br /> o \ \\ I I ENTITY#: <br /> 4X BLK'G. <br /> 04 <br /> �I o = \ \ <br /> co \ I <br /> PROJECT <br /> CD, ,o INSERT FLASH�G BELOW SILL \ TACO BELL <br /> co C) 3' DIAM. ABS <br /> RECEPTOR THE AULK \ 5/8"GYPSUM BOARD 532 WEST HAMMER LN <br /> — — — — — OVERFLOW PIPE <br /> M� �o \\ THRU WALL CORTEN PANEL 1"OVER BLUESKIN CORTEN PANEL 1"OVER BLUESKIN INSULATION SHEATHING STOCKTON, CA. 95210 <br /> a= z w OVER 1/2"PLYWOOD SHEATHING OVER 1/2"PLYWOOD SHEATHING <br /> E m z — — — — — — — — — — — , USE STAINLESS STEEL SCREWS PER USE STAINLESS STEEL SCREWS PER APN#000-000-000 <br /> E ms <br /> o w WINDOW FLASHING - MANUFACTURER'S MANUFACTURER'S <br /> ALUMINUM RECOMMENDATION RECOMMENDATION <br /> Uj MAINTAIN POSITIVE <br /> �I Z 0 DRAINAGE AWAY FINISH TO MATCH <br /> C:> Z w FROM WALL AT STOREFRONT I I <br /> < > <br /> "o ALL FLASHING <br /> C) NOTE: DO NOT CAULK/ <br /> N E 0 1 BLUESKIN VP WATER I BLUESKIN VP WATER <br /> m OBSTRUCT WEEP HOLES ENDEAVOR <br /> RESISTIVE AIR BARRIER RESISTIVE AIR BARRIER <br /> DRILLED IN SILL RECEPTOR 3" DIAM. ABS DRAIN PIPE MEMBRANE MEMBRANE <br /> � �� 1/2"PLYWOODSUCCESSOR M 11/13/2020 <br /> a > DN THRU FACE OF WALL X SHEATHING <br /> rnI z= FASTENER AT 12"O.C. FASTENER AT 12"O.C. <br /> ABOVE SILL PLATE. WOOD STUDS 1 SHEET METAL FLASHING WOOD STUDS I HARDIE PLANK <br /> d) 2N o 1" BEYOND FACE OF PLASTER I CONSTRUCTION <br /> CORTEN T GROOVE BLUESKIN VP <br /> COMPLETING WINDOW SYSTEM 1/2 PLYWOOD 1/2"PLYWOOD DETAILS <br /> E U)< SHEATHING SHEATHING METAL WALL PANEL WATER RESISTIVE <br /> `� � AIR BARRIER <br /> U) SINGLE PLY WALL <br /> SET STOREFRONT WINDOW, APPLY STUCCO SYSTEM AND THEN ADD WINDOW REFER TO PLUMBING ROOFING MEMBRANE <br /> co a = FLASHING OVER TOP OF STUCCO AT WINDOW SILL PLANS FOR PIPE <br /> a o TERMINATION DETAILS, 0 <br /> ca 6o � <br /> Z TYP. N <br /> c� <br /> d Ujw o <br /> o <br /> CU w� <br /> coUj <br /> ¢= D <br /> 1 1 6m2 a TYPICAL WINDOW WATER PROOFING 20 ROOF SUMP + OVERFLOW @ (N) ADDITION 1" = V-0' 16 METAL PANEL OVER BLUESKIN SJ 11/2" = 1'-0" 12 METAL PANEL OVER BLUESKIN 11/2" = V-0" 8 VERTICAL OUTSIDE CORNER 111211 — 1'-0" 4 <br />