Laserfiche WebLink
GENERAL NOTES GENERAL SCOPE <br /> A. CONFIRM LIGHTING FIXTURE QUANTITIES WITH SUPPLIER. O REPLACE ALL LIGHT FIXTURES (EXCEPT HOOD AND WALK-IN) <br /> B. EMERGENCY AND NORMAL LIGHTING MARKED WITH "NL" O RECOMISSION HVAC SYSTEM (REFURBISH AND REPLACE TO ORIGINAL SPECS) <br /> SUBSCRIPT SHALL OPERATE CONTINUOUSLY. PROVIDE <br /> UNSWITCHED HOT TO NORMAL AND EMERGENCY BALLAST. <br /> LIGHTING CONTROLS C. EMERGENCY LIGHTING TO BE LEFT IN PLACE. <br /> D. ALL CONDUITS ENTERING OR LEAVING COOLER/FREEZER NOTE: <br /> REFER TO ENERGY COMPLIANCE DRAWINGS, SHALL BE PROVIDED WITH SEAL-OFF FITTING WITH COMPOUND 1. ALL INTERIOR LIGHTING CIRCUITS TO RUN THROUGH EXISTING ENERGY <br /> o T24-1AND T24-2, FOR INSTALLATION PER NEC 300-(7a). MANAGEMENT SYSTEM LIGHTING CONTROL PANEL FOR AUTOMATIC CONTROLS. <br /> ui <br /> 02 RI ISOLATED GROUND FOR DIGITAL MENU BOARDS- REQUIREMENTS INCLUDING, BUT NOT E. ALL INTERIOR LIGHTING CIRCUITS TO BE WIRED THRU THE 2. ALL EXTERIOR LIGHTING TO RUN THROUGH EXISTING EMS TIME CLOCK. <br /> U) LIMITED TO SWITCHING,ZONING AND LIGHTING CONTROL RELAYS. 3. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS&CONDITIONS ON SITE. <br /> GC TO VERIFY WHICH EXISTING ELECTRICAL PANELS HAS THE ISOLATED GROUND DAYLIGHT CONTROLS. NEW LIGHTING F. CONTRACTOR TO FIELD VERIFY CEILING TYPE AND PROVIDE 4. CONTRACTOR TO FIELD VERIFY AND MAINTAIN ALL FIRE SYSTEMS. <br /> uj <br /> AND TO INSTALL THE NEW DIGITAL MENU BAORDS ON THIS ISOLATED GROUND INSTALLATION SHALL COMPLY WITH ENERGY PROPER MOUNTING HARDWARE. 5. DEMOLITION &REMOVAL OF SYSTEMS NOTED INCLUDES ALL WORK REQUIRED <br /> w o DOCUMENTATION. G. ALL FIXTURES SUPPLIED WITH LAMPS. I TO ACHIEVE SCOPE OF NEW WORK AND DESIGN INTENT. <br /> 0 <br /> Ir (EEO H. ALL LIGHTS SUPPLIED BY OWNER AND INSTALLED BY G.C. <br /> o C) ORDER KIOSK I. GC TO PROVIDE INDOOR &OUTDOOR LIGHTING MEASURES TO DIGITAL MENU BOARD NOTES: <br /> s m COMPLY WITH CA T-24 REQUIREMENTS PER LIGHTING 1. EC/GC .TO CONTACT DMB VENDER AND SCHEDULE SITE SURVEY FOR SYSTEM <br /> N PROVIDE 20 AMP, 120 V DEDICATED CIRCUIT TO BE 7 RI MANDATORY MEASURES LABELED LTG-MM AS SPECIFIED ON SPECIFICATIONS AND REQUIREMENTS OF DMB INSTALLATION. <br /> INSTALLED PRIOR TO KIOSK INSTALLERS ARRIVAL I FA-17 2. ONCE VENDER HAS RECEIVED THE DMB SITE SURVEY ORDER,THE VENDERS DMB <br /> CD CEILING ABOVE. MC CABLE LEFT IN CEILING SHEET T24'S.THESE INCLUDE AUTOMATIC CONTROL DEVICES, <br /> Z Z OVERRIDE SWITCH FOR BUILDING LIGHTING SHUT OFF, IMPLEMENTATION TEAM WILL CONTACT OWNER/CONTRACTOR WITHIN 1-3 Lf <br /> w DAYLIGHT SWITCHES &LIGHTING CONTROL.ADJUST EXISTING BUSINESS DAYS TO REVIEW EVERYTHING NEEDED FOR DMB INSTALL. vM, 21"GIIItCGtUI"C <br /> o X1 @ 16'-0" CIRCUITING AS REQUIRED FOR COMPLIANCE. ALL EXTERIOR 3. EC/GC TO INSTALL A TOTAL OF (4) IG5262 DUPLEX OUTLETS IN (2) QUAD BOXES <br /> a o D1 o D1 Design Planning — Interiors <br /> B1 LIGHTS AND SIGNAGE TO BE CONTROLLED VIA TIME CLOCK, ON FRONT OF VALANCE WALL. OUTLETS TO BE ORANGE&STRAIGHT BLADE. <br /> o OUTLETS TO BE ON A 24/7 ISOLATED/DEDICATED CIRCUIT THAT IS NOT 637 5th Avenue San Rafael, CA 94901 <br /> w ® B- 1e "SUPPLIED BY THE GC IF NOT CURRENTLY EXISTING." 415-451-2500 415-451-2595 fax <br /> M J. PENDANT LIGHTS SHALL BE CENTERED OVER TABLES. VERIFY CONNECTED TO ANY RESTAURANT POWER MANAGEMENT SYSTEM. <br /> Q 4 RI www.vmarch.com <br /> UJ o X1 @ 18'-0" TABLE LOCATIONS WITH SEATING VENDOR SUPPLIED CORE <br /> 4. EC/GC TO INSTALL(1) OPEN DATA JUNCTION BOX(JB) IN VALANCE WALL PER <br /> Of <br /> o 1 D1 DRILL PLAN PRIOR TO LOCATING PENDANTS. VENDER REQUIREMENTS. CONDUIT TERMINATED ABOVE CEILING TO HAVE <br /> cn C1W _ _ _ _ BUSHING. VMI JOB NUMBER <br /> K. DOWNLIGHTS IN BLACK DROPPED CEILING SHALL HAVE BLACK <br /> O 5. EC/GC TO RUN (3) CAT6 LINES FROM NETWORK SWITCH TO DATA JUNCTION BOX. 20049 <br /> F 7 F 7 F F 7 g 7a TRIM RINGS. <br /> No B-9 B x B 9x B x g_ 1 CAT6 LINES SHOULD HAVE BOTH ENDS PROPERLY TERMINATED WITH RJ-45 <br /> o B1 E) PANEL A (E) PANEL B L. ALL E2& EM2 FIXTURES ARE NEW FIXTURES TO REPLACE <br /> � C1 W - 1 EXISTING IN EXISTING LOCATIONS.ALL REPLACED EMERGENCY CONNECTORS. EXCESS CAT6 CABLE TO BE COILED INTO SERVICE LOOPS AT EACH <br /> > B- 7a 61 FIXTURES SHALL BE REPLACED WITH SAME. <br /> END AND LEFT ACCESSIBLE FOR DMB INSTALL TEAM. CAT6 TO BE RUN IN <br /> Z o ACCORDANCE WITH ALL LOCAL MUNICIPALITY CODE REQUIREMENTS. <br /> B- 1 e M. ADJUST POSITION OF AIR SUPPLY DIFFUSERS ALONG WITH THE �Y ARS' <br /> 0 uj o ® 12 RI ASSOC. DUCT WORK. 6. EC/GC SHALL ACQUIRE AND SECURE ANY/ALL REQUIRED PERMITTING FOR THE � <br /> o~ 8 RI WORK MENTIONED ABOVE PER LOCAL MUNICIPALITY CODE REQUIREMENTS. <br /> o m B1 B1 N. REPLACE OR REPAIR THE EXISTING AIR CONDITION SYSTEM SO y� AR <br /> 01 Lu E1 W C1 W C1 W C1 W C1 W B- 1 e B- le THAT IT FUNCTIONS AS IT WAS ORIGINALLY DESIGNED OR LIGHTING CONTROL KEYED NOTES 0 <br /> o BETTER, INCLUDING A RE-BALANCE. <br /> U � O O O O B1 E B1 B1 E 0. WHERE INDICATED, LIGHTING CONTROLLED VIA OCCUPANCY <br /> a B 7a B-7a B-7a B 7a B- 1 e B- 1 e - 1 SENSORS, SEE SHEET E3.0. 1. ALL GENERAL LIGHTING WITHIN DAYLIGHT ZONES SHALL BE SEPARATELY CONTROLLED FROM * x No. C17928 <br /> LL U) B-17 GENERAL AREA LIGHTING IN COMPLIANCE WITH SECTION 130.1(D)OF CEC BUILDING ENERGY <br /> Lu EFFICIENCY STANDARDS. REN. 1031 X23 <br /> o I C1 W 6RI cp?�� 1Q <br /> U)0 2. LINE DENOTING DAYLIGHT ZONE TYPICAL FOR ALL AREAS ADJACENT TO VERTICAL FENESTRATION WITH <br /> DIMENSIONAL CRITERIA AS FOLLOWS: <br /> Z`� C B1 DEPTH: �F CALI�O <br /> a O 13 R 5'-5" 1 <br /> o J B1 E -WINDOW HEIGHT INTO SPACE,OR TO NEAREST CEILING HEIGHT OPAQUE PARTITION <br /> w E2 +95") B 1 e B1 B1 (WHICHEVER IS LESS). <br /> Lu B-17 B 1 WIDTH: <br /> 0 0 �/ F6 C1�/ CO C1 O B1 B 1 -WIDTH OF WINDOW PLUS ONE-HALF TIME WINDOW HEAD HEIGHT ON EACH SIDE,OR WINDOW <br /> W = g-9X WIDTH PLUS DISTANCE TO OPAQUE PARTITIONS,OR WINDOW WIDTH PLUS ONE HALF THE DISTANCE TO <br /> o C6 B-7a B 7b 9 RI B-7b g 7b 2 3 ADJACENT SKYLIGHT OR VERTICAL FENESTRATION(WHICHEVER IS LESS). <br /> o ( 95") B- 1 e 3 PROVIDE CEILING MOUNTED DAYLIGHT SENSOR FOR EACH DAYLIGHT ZONE TO CONTROL GENERAL <br /> Lu a I F6 OQ LIGHTING LUMINARIES WITHIN THE DAYLIGHT ZONE.LOCATION AND CALIBRATION OF SENSOR SHALL NOT <br /> Lu X1 @ 16' 0" i B 9x 5 RIEH <br /> +95") 1'-0" e BE READILY ACCESSIBLE TO UNAUTHORIZED PERSONNEL AND SHALL BE CONFIGURED IN THE FIELD. <br /> J = 4. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS LOGISTICALLY LOCATED IN THE SALES AREA TO <br /> F6 FMB AUTOMATICALLY SHUT OFF ALL LIGHTING WHEN THE SPACE IS TYPICALLY UNOCCUPIED IN COMPLIANCE <br /> cn °' E1 W B 9 BULKHEAD B1 B1 E 9 D WITH SECTION 130.1(C)OF THE CEC BUILDING ENERGY EFFICIENCY STANDARDS. <br /> Q o B-17 <br /> 6) ( 95") 0 B 1 e B 1 e <br /> a�_„ I 5. PROVIDE DIMMER SWITCHES COMPATIBLE WITH LIGHTING FIXTURES BEING INSTALLED.REFER TO FIXTURE <br /> o z C11 W C1OW C1OW C1OW (+950 2'-3" L SCHEDULE ON ARCHITECTURAL SHEETS FOR MORE FIXTURE INFORMATION.DIMMERS SHALL BE EQUIPPED <br /> o i WITH MANUAL ON/OFF CAPABILITY FOR ALL SALES AREA LIGHTING IN COMPLIANCE WITH SECTIONS 130.1 <br /> U)0 — <br /> Lu QB- 7a F6 CO) B-7b B- 7b B- 7b C1 W__1_ a <br /> ui zo EFFICIE(B)FOR AREA NCY STANDARDS.FINAOLLS AND LOCAT LOCATION CONTRIGHTING OLS 0 BELS OF THE CECVERIFIEDWITH TACO BUILDING ENERGY <br /> Q B 9x ( 95) 4' 2" c 11 RI B1 CONSTRUCTION MANAGER. <br /> <o I b 01 + 44" B- 1e <br /> z TYPICAL LIGHTING CONTROL DETAIL <br /> I (NOT TO SCALE) <br /> W Lu B-17 d ® B1E (0:o� X1W B1E ® B 1e <br /> ]�V i ]�N <br /> Z I 46-1 CO O CV CVW CV <br /> -o <br /> o ¢ B- 7a B- 7a B-7a Ile B- 7a B- 7aB1E <br /> z> - 1 5 <br /> B- 1f <br /> wZ r® <br /> M & B1 E o B1 <br /> B1 E <br /> � B 1e B1e RECORD DATES <br /> N o 8 RI 3 DD SUBMITTAL <br /> U O <br /> C,4 LU Uj BLDG.SUBMITTAL 21412022 <br /> 4 RI <br /> N �m <br /> C:) =? h BID SET - <br /> 04 C1W C1W C1W <br /> N F7 F70 O O O f ® ® B 1f 61 <br /> o o g_9� _ 4 RI B-7a B-7a B-7a ® B 1 e CONTRACT SET <br /> C) U= 1w E1W x1w B 17 REVISIONS <br /> (D w ~ B-17 tB-17 <br /> cu 0< <br /> co <br /> OS O <br /> O m <br /> Qo w D1 D1 <br /> <z X19 12-0'2 B E2 X1 @ 24'-0'—' DAYLIGHTZONE <br /> U' o0 <br /> w Z <br /> Z �o <br /> Q os l v JD1 o D1 4 <br /> o w o ��--// 13 RI NORTH <br /> a <br /> ca LU <br /> �, o o LIGHTING PLAN 1/411-1'-0 A <br /> 3: -Z a� <br /> o > O OCCUPATIONAL SENSOR + 44"A.F.F. <br /> Lu1 0< _ _ _ — (U.O.N.)TO CENTERLINE OF SWITCH REMODEL IMAGE (RI) <br /> LL 1 RI POWER AND DATA FOR FUTURE DIGITAL KIOSK. CLIENT <br /> N �o NO. QUANTITY LOCATION MANUFACTURER/CATALOG NUMBER DESCRIPTION LAMP MOUNTING VOLT WATT REMARKS �' 4 DUI O N.R O CENTERLINE OF SWITCH 2 RI COORDINATE MOUNTING HEIGHT WITH EXISTING SOFFIT.WITCHES +4411 A.F.F. PRB MANAGEMENT INC <br /> w o TYPE TYPE HT. SAFE ( ) O <br /> o o 3 SITE SES-25-40-01-F-B4-DBT LED <br /> 3 RI EXISTING SMOKE DETECTORS TO REMAIN. 4709 Mangels Blvd. <br /> m A POLE VP L-96L 395-4K7-4 UNV A-DBT POLE 25'-0" 120 395 <br /> Fairfield,CA 94534 <br /> HOLD-UP BUTTON (MOUNT 2-112" O SITE#:3560 <br /> EC SHALL INSTALL SHOW WINDOW RECEPTACLE IF NONE ARE PRESENT. <br /> w BEHIND COUNTER EDGE) + 16"A.F.F. 4 RI EC SHALL PROVIDE (1) 20A, 120V CIRCUIT BACK TO SPARE CIRCUIT IN EXISTING <br /> L "Q 3 SITE SES-25-40-01-F-B4-DBT LED <br /> � "_ B POLE VP L-96L 395-4K7-5R UNV A DBT POLE 25'-0" 120 395 PANELBOARD. NEW CIRCUIT BREAKER SHALL MATCH TYPE AND RATING OF ENTITY#: <br /> ,I o> " 0 J-BOX EXISTING BREAKERS. <br /> LLQ C1 4 EXTERIOR TCP 6 30K 90CRI BLACK TRIM, LED RECESSED 120 14 WET LOCATION <br /> MI CANOPIES B61C AT-B LED14/DR5630KB95 W/ELITE B6IC-AT-W 6" HRD CLG INCL / 2"x 4"J BOX W/DATA PORTS +16"A.F.F. 5 RI REINSTALL EXISTING FRONT COUNTER POWER AND DATA CONNECTIONS. INCLUDE PROJECT <br /> o w o TCP 6"30K 90CRI WHITE TRIM, WITHIN D3/4"ICONDU TTION OF OR DATA/PHONE ADUPLEX ND ALL ASSOC ATDED WIRING. (7) 2"X4"J-BOX TACO BELL <br /> � g U C1 W 24 DINING W/ELITE B6IC-AT-W 6" LED RECESSED 120 14 INCL <br /> U-, a B6IC-AT-W-LED14/DR5630KB95 — DUPLEX ISOLATED GROUND OUTLET O 532 WEST HAMMER LN <br /> ch w� _ _— _ o +16"A.F.F., U.O.N. 6RI POWER AND DATA FOR DIGITAL MENUBOARDS. <br /> I o EXTERIOR T R 0 Y 17"X14"WALL MOUNT SCONCE, OLD WALL, CENTER OF BRACKE —1 STOCKTON, CA. 95210 <br /> Z D1 8 WALL B2772 SILVER FINISH, MEDIUM BASE LED 120 9 DOUBLE DUPLEX ISOLATED GROUND OUTLET (EEO PROVIDE GROUND FAULT DUPLEX OUTLET FOR (N)AIR CURTAIN. INTERLOCK AIR <br /> a @ 14'-0"A.F.F. <br /> z LED9A19D2527K SOCKET,30 WATT MAX CURTAIN W/DT WINDOW. CIRCUIT TO (E) PANEL 2.5 AMPS (1 POLE 20 AMP APN#000-000-000 <br /> E m o LED9A19D2527K U) +16"A.F.F., U.O.N. BREAKER). <br /> cz z <br /> _ o DINING HUB TABLE 9.75"GLASS PENDANT AVERY WITH (1)AAMSCO J <br /> cn o s F6 4 PENDANT SEE 120 6 LED-6W-ST64HYBRID-DIM o Q z 8 RI PROVIDE PRIMARY DAYLIGHT ZONE SENSOR. <br /> a� w w KICHLER 438520Z OLD BRONZE FINISH LED ELEV'S w w <br /> a U w 9 RI PROVIDE SECONDARY DAYLIGHT ZONE SENSOR. <br /> �I z� F7 6 DINING PERIMETER TABLE 12"GALVANIZED PENDANT W/BLACK PENDANT SEE 120 20 (1) IUPLIzL)10A19UUL)2/K <br /> Y Z o HI-LITES H24212-96-CB15-20WLBL-60P CORD AND CANOPY MED BASE LED ELEV'S m ALL OUTLETS AND BOXES MOUNTED IN THE 10 RI LIGHT CONTROLLED BY MOTION SENSOR. �� o <br /> SERVING COUNTER CABINETRY ARE TO BE 24 AFF. 4QO ��LL <br /> o C) KITCHEN MAXLITE RECESSED <br /> w <br /> 31 13 2x4 LED FLAT PANEL LED 120 45 - INSTALL JUNCTION BOXES WITH CONDUIT UNDER 11 RI DIMMING SWITCH BANK WITH 2 HOUR BYPASS TO MEET TITLE 24 MANDATORY <br /> DINING MLFP24G427WCS GRID o CABINET TO NEAREST WALL AND TO ABOVE MEASURES ENDEAVOR <br /> m m w KITCHEN MAXLITE SEE PLAN CEILING. SUCCESSOR M 11/13/2020 <br /> a w B1 E 12 2x4 LED FLAT PANEL LED 120 45 - 12 RI PROVIDE ELECTRICAL OUTLET FOR PRIVATE LACTATION AREA IN OFFICE. <br /> Q RESTROOM MLFP24G427WCS <br /> Z PROVIDE DEDICATED OUTLET FOR SAFE. <br /> LIGHTALARMS EXTERIOR EMERGENCY SEE KEY UNSWITCHED'HOT'WITH <br /> CD a� E2 2 EXTERIOR CAM-SD-DB-CW EGRESS FIXTURE LED WALL NOTES 120 18 90 MIN. BATTERY BACK UP — — E.C. SHALL PROVIDE A PREPRINTED LIGHTING <br /> a� E1 W 3 DINING LIGHT ALARMS 2 HEAD EMERGENCY LED WALL SEE 120 5 PROVIDED WITH 90 MIN. SELF-ADHESIVE LABEL ON ALL POS RECEPTACLES <br /> E z KITCHEN EM-809-W WHITE ELEV'S BATTERY PACK STATING POS USE ONLY". PLAN AND <br /> Lu <br /> cm cu j o X1W 3 KITCHEN EXISTING TO REMAIN UNIVERSAL MNTG THERMOPLASTIC WALL SEE 120 2.8 PROVIDED WITH INTEGRAL G.C.TO COORDINATE DIMENSIONS WITH OWNERS SCHEDULE <br /> L DINING LIGHT ALARMS EXIT, RED LETTERS-WHITE LED ELEV'S BATTERY BACK UP <br /> a o X1 86'-0" EXTERIOR TOKISTAR LIGHTING OUTDOOR LED LED NA 120 2/FT REPRESENTATIVES. <br /> CD z o #EXBK-I8-WW-C STRING <br /> Z <br /> w <br /> � <br /> c <br /> Co u — <br /> o El ■ <br /> o w w <br /> LIGHTING FIXTURE SCHEDULE E NOT USED D (IF REQUIRED) 5 RI FRONT COUNTER DETAIL C KEY NOTES B <br />