My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
532
>
1600 - Food Program
>
PR0162092
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 1:13:49 PM
Creation date
3/7/2022 2:16:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0162092
PE
1625
FACILITY_ID
FA0002914
FACILITY_NAME
TACO BELL #3560
STREET_NUMBER
532
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08152043
CURRENT_STATUS
01
SITE_LOCATION
532 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W:1Data1PRB Management120049_PRB_Stockton WestHammer 3560103_cd1 current1015_20049_T24-1.dwg By: DHAMMOND Saved on:1/31/2022 3:23:31 PM <br /> ALL IDEAS,DESIGNS,ARRANGEMENTS AND PLANS INDICATED BY THIS DRAWING ARE OWNED BY,AND THE PROPERTY OF THIS OFFICE AND WERE CREATED,EVOLVED AND DEVELOPED FOR USE ON,AND IN CONNECTION WITH,THE SPECIFIED PROJECT. NONE OF SUCH IDEAS,DESIGNS,ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON,FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF PROJECT ARCHITECT. <br /> WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR,ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS OF ADEQUATE SCALE MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION ON ITEMS SO NOTED. <br /> STATE OF CALIFORNIA STATE OF CALIFORNIA <br /> Outdoor Lighting Outdoor Lighting <br /> NRCC-LTO-E CALIFORNIA ENERGY COMMISSION NRCC-LTO-E CALIFORNIA ENERGY COMMISSION <br /> CERTIFICATE OF COMPLIANCE NRCC-LTO-E CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br /> Project Name: Taco Bell Remodel Report Page: (Page 6 of 8) Project Name: Taco Bell Remodel Report Page: (Page 2 of 8) <br /> Project Address: 532 West Hammer Road Date Prepared: 1/31/2022 Project Address: 532 West Hammer Road Date Prepared: 1/31/2022 <br /> M.LIGHTING ALLOWANCE:PER SPECIFIC AREA C.COMPLIANCE RESULTS <br /> This table includes areas using the wattage allowance per specific area from Table 140.7-B.More than one specific area allowance may be taken in a single project if applicable. Results in this table are automatically calculated from data input and calculations in Tables F through 1.Note:If any cell on this table says"COMPLIES with Exceptional Conditions"refer <br /> However,multiple specific area allowances may not be taken for the exact some area on the site. to Table D.Exceptional Conditions for guidance or see applicable Table referenced below. <br /> 01 02 03 04 05 06 07 08 09 10 Calculations of Total Allowed Lighting Power(Watts) 140.7 or§141.0(b)2L Compliance Results <br /> CALCULATED ALLOWANCE(Watts) DESIGN WATTS Additional 01 02 03 04 05 06 07 08 09 <br /> Specific Area Type per Table Allowed Extra Luminaire General Existing <br /> Area Description Specific Area Watts per #of Allowance Per Sales Per Specific <br /> 140.7-B Design Watts Ornamental <br /> (ft2)' Density Allowance Name or Luminaire Luminaires (Watts) Hardscape + Application + Frontage + + Area OR Power = Total Allowed ? Total Actual <br /> (W/ft2) (Watts) Item Tag Allowance §1407(d)2 Allowance. 07 must be>=08 <br /> §140.7(d)2 §140.7(d)2 §140.7(d)2 (Watts) (Watts) <br /> §140.7(d)1 (See Table J) (See Table K) (See Table L) (See Table M) §141.0(b)2L <br /> D1 9 8 72 (See Table 1) 1 1 1 (See Table N) <br /> Building Facade BuildingFacade 2832 0.17 481.4 244 1,056.75 + + + I --- I + 1 244 1 OR --- = 1,300.75 > 1,149 COMPLIES <br /> X1 2 86 172 Cutoff Compliance(See Table G for Details) N/A <br /> Total Design Watts for this Area: 244 Controls Compliance(See Table H for Details) COMPLIES with Exceptional Conditions <br /> 244 <br /> 'FOOTNOTES:See Table 140.7-8 for rules for calculating the specific areas(ft2 for these additional lighting allowances. Total Allowance(Watts)All Areas: D.EXCEPTIONAL CONDITIONS <br /> 2 This table is auto filled with uneditable comments because of selections made or data entered in tables throughout the form. <br /> For luminaires indicated in Table Fos linear,wattage in column 07 is W/If instead of Watts/luminaire.Total linear feet should be indicated in column 08 instead of number of luminaires. <br /> N.EXISTING CONDITIONS POWER ALLOWANCE(alterations only) E.ADDITIONAL REMARKS <br /> This section does not apply to this project. IThis table includes remarks made by the permit applicant to the Authority Having Jurisdiction. <br /> O.DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION <br /> Selections have been made based on information provided in this document.If any selection have been changed by permit applicant,an explanation should be included in Table E. <br /> Additional Remarks.These documents must be provided to the building inspector during construction and can be found online at <br /> https://www.energy.ca.gov/title24/2019standards/2019_compliance_documents/Nonresidential Documents/NRCl/ <br /> Form/Title Field Inspector <br /> Pass Fail <br /> NRCI-LTO-01-E-Must be submitted for all buildings ❑ ❑ <br /> NRCI-LTO-02-E-Must be submitted for a lighting control system,or for an Energy Management Control System(EMCS),to be recognized for ❑ ❑ <br /> compliance. <br /> Registration Number: Registration Date/Time: Registration Provider:Energysoft Registration Number: Registration Date/Time: Registration Provider:Energysoft <br /> CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:2019.1.003 Report Generated:2022-01-3111:56:12 CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:2019.1.003 Report Generated:2022-01-3111:56:12 <br /> Schema Version:rev 20200601 Schema Version:rev 20200601 <br /> STATE OF CALIFORNIA STATE OF CALIFORNIA <br /> Outdoor Lighting Outdoor Lighting <br /> NRCC-LTO-E CALIFORNIA ENERGY COMMISSION NRCC-LTO-E CALIFORNIA ENERGY COMMISSION <br /> CERTIFICATE OF COMPLIANCE NRCC-LTO-E CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br /> Project Name: Taco Bell Remodel Report Page., (Page 7 of 8) Project Name: Taco Bell Remodel Report Page: (Page 3 of 8) <br /> Project Address: 532 West Hammer Road Date Prepared: 1/31/2022 Project Address: 532 West Hammer Road Date Prepared: 1/31/2022 <br /> P.DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE F.OUTDOOR LIGHTING FIXTURE SCHEDULE <br /> Selections have been made based on information provided in this document.If any selection have been changed by permit applicant,an explanation should be included in Table E. For new or altered lighting systems demonstrating compliance with 140.7 all new luminaires being installed and any existing luminaires remaining or being moved within the spaces <br /> Additional Remarks.These documents must be provided to the building inspector during construction and must be completed through an Acceptance Test Technician Certification covered by the permit application are included in the Table below.For altered lighting systems using the Existing Power method per§141.0(b)2L only new luminaires being installed and <br /> Provider(ATTCP).For more information visit:http://www.energy.ca.gov/title24/attcp/providers.html replacement luminaires being installed as part of the project scope are included(ie,existing luminaires remaining or existing luminaires being moved are not included). <br /> Form/Title Systems/Spaces To Be Field Field Inspector Designed Wattage: <br /> Verified Pass Fail 01 02 03 04 05 06 07 08 09 10 <br /> NRCA-LTO-02-A-Must be submitted for all outdoor lighting controls except for alterations where controls are added to<= ❑ ❑ Cutoff Req.> Field <br /> 20 luminaires. How is <br /> Name or Item Watts per Total number Luminaire Excluded per 6,200 initial Inspector <br /> Tag Complete Luminaire Description luminaire',' Wattage luminaires2 Status3140.7 a Design Watts lumen output <br /> determined 130.2 b 4 Pass Fail <br /> A A-Pole Mount>24' El Linear 181 Mfr.Spec 3 New El 543 <6200 543 E] E]lumens <br /> NA:<6200 <br /> B B-Pole Mount>24' ❑ Linear 181 Mfr.Spec 2 New ❑ 362 _ ❑ ❑ <br /> iunieiu <br /> D1 D1-Exterior Wall Pack ❑ Linear 9 Mfr.Spec 8 New ❑ 72 NA:<6200 ❑ ❑ <br /> lumens <br /> X1 X1-2W/FT LED ❑ Linear 2 Mfr.Spec 86 New ❑ 172 NA:<6200 ❑ ❑ <br /> lumens <br /> Total Design Watts: 1149 <br /> *NOTES:Selections with a*require a note in the space below explaining how compliance is achieved. <br /> EX:Luminaire is lighting a statue;EXCEPTION 2 to§130.2(b) <br /> 'FOOTNOTES:Authority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per 130.0 c <br /> z For linear luminaires,wattage should be indicated as W/If instead of Watts/luminaire.Total linear feet should be indicated in column 05 instead of number of luminaires. <br /> 3 Select"New"for new luminaires in a new outdoor lighting project or for added luminaires in an alteration.Select"Altered"for replacement luminaires in an alteration.Select"Existing to Remain" <br /> for existing luminaires within the project scope that are not being altered and are remaining.Select"Existing Reinstalled"for existing luminaires which are being removed and reinstalled as part of <br /> the project scope. <br /> 4 Compliance with mandatory cutoff requirements is required for luminaires with initial lumen output>=6,200 unless exempted by§130.2(b) <br /> G.CUTOFF REQUIREMENTS(BUG) <br /> This section does not apply to this project. <br /> Registration Number: Registration Date/Time: Registration Provider:Energysoft Registration Number: Registration Date/Time: Registration Provider:Energysoft <br /> CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:2019.1.003 Report Generated:2022-01-3111:56:12 CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:2019.1.003 Report Generated:2022-01-3111:56:12 <br /> Schema Version:rev 20200601 Schema Version:rev 20200601 <br /> STATE OF CALIFORNIA STATE OF CALIFORNIA <br /> Outdoor Lighting Outdoor Lighting <br /> NRCC-LTO-E CALIFORNIA ENERGY COMMISSION NRCC-LTO-E CALIFORNIA ENERGY COMMISSION <br /> CERTIFICATE OF COMPLIANCE NRCC-LTO-E CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br /> Project Name: Taco Bell RemodelReport Page: (Page 8 of 8) Project Name: Taco Bell Remodel Report Page: (Page 4 of 8) <br /> Project Address: 532 West Hammer Road Date Prepared: 1/31/2022 Project Address: 532 West Hammer Road Date Prepared: 1/31/2022 <br /> DOCUMENTATION AUTHOR'S DECLARATION STATEMENT H.OUTDOOR LIGHTING CONTROLS <br /> certify that this Certificate of Compliance documentation is accurate and complete. This table demonstrates compliance with controls requirements for all new or altered luminaires installed as part of the permit application.For alteration projects,luminaires which are <br /> Documentation Author Name: Docu entation utho�r Signature: existing to remain(ie untouched)and luminaires which are removed and reinstalled(wiring only)do not need to be included in this table even if they are within the spaces covered by <br /> Nicholas Mott A" �f/lg the permit application. <br /> Company: Signature Date: When an option having a*is selected,the notes section of this table must be completed.The lighting controls section of the Compliance Summary Table on the first page will show <br /> Wade Energy 2022-01-31 "DOES NOT COMPLY"if the notes are left blank. <br /> Address: CEA/HERS Certification Identification(if applicable): Mandatory Controls <br /> 1942 Linda Drive N/A 01 02 03 04 05 <br /> City/State/Zip: Phone: <br /> Pleasant Hill CA 94523 925-383-5490 Shut-Off Auto-Schedule Motion Sensor Field Inspector <br /> RESPONSIBLE PERSON'S DECLARATION STATEMENT Area Description 130.2 c 1 §130.2(c)2 §130.2(c)3 <br /> I certify the following under penalty of perjury,under the laws of the State of California: Pass Fail <br /> 1. The information provided on this Certificate of Compliance is true and correct. Building Facade Photocontrol Yes Exempt* ❑ ❑ <br /> 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance(responsible designer) <br /> 3. The energy features and performance specifications,materials,components,and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements Parking LOt PhotOCOntr01 Yes NA:Facade,etc.>=24 ft El El <br /> of Title 24,Part 1 and Part 6 of the California Code of Regulations. *NOTES:Controls with a*require a note in the space below explaining how compliance is achieved. <br /> 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,worksheets,calculations, EX.Not permitted by health&safety to be turned off,EXCEPTION 1 to 113Q.2c <br /> plans and specifications submitted to the enforcement agency for approval with this building permit application. <br /> 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s)issued for the building,and made available to the enforcement agency for all applicable Building Facade All fixtures less than 40W <br /> inspections.I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. <br /> Responsible Designer Name: Responsible Designer Signature: f n <br /> Hugh Murphy <br /> Company: Date Signed: <br /> VMI Architecture,Inc. 2022-01-31 <br /> Address: License: <br /> 637 5th Avenue C17928 <br /> City/State/Zip: Phone: <br /> San Rafael CA 94901 415-451-2500 <br /> Registration Number: Registration Date/Time: Registration Provider:Energysoft Registration Number: Registration Date/Time: Registration Provider:Energysoft <br /> CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:2019.1.003 Report Generated:2022-01-3111:56:12 CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:2019.1.003 Report Generated:2022-01-3111:56:12 <br /> Schema Version:rev 20200601 Schema Version:rev 20200601 <br /> STATE OF CALIFORNIA <br /> Outdoor Lighting <br /> NRCC-LTO-E CALIFORNIA ENERGY COMMISSION <br /> CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br /> Project Name: Taco Bell Remodel Report Page: (Page 5 of 8) <br /> Project Address: 532 West Hammer Road Date Prepared: 1/31/2022 <br /> I.LIGHTING POWER ALLOWANCE(per§140.7) <br /> This table includes areas using allowance calculations per 140.7.General Hardscape 01 <br /> Allowance is per Table 140.7-A while"Use it or lose it"Allowances are per Table 140.7-B. ® General "Use it or lose it"Allowance(select all that apply)(select all that apply) <br /> Indicate which allowances are being used to expand sections for user input.Luminaires Hardscape p El Per ® Per Specific <br /> that qualify for one of the"Use it or lose it"allowances shall not qualify for another"Use El Sales Frontage El Ornamental Allowance Application Area <br /> it or lose it"allowance. Table I(below) Table J Table K Table L Table M <br /> Calculated General Hardscape Lighting Power Allowance per Table 140.7-A(LZ 0,1&4) <br /> Calculated General Hardscape Lighting Power Allowance per Table 140.7-A(LZ 2&3) <br /> 02 03 04 1 05 06 07 08 1 9 10 <br /> Area Wattage Allowance(AWA) Area Wattage Allowance(AWA) <br /> Total General <br /> Area Description Surface Type Illuminated Allowed Area Allowance Perimeter Allowed Linear AWA+LWA <br /> Area(ft2) Density(W/ft2) (Watts) Length(If) Density(W/If) Allowance (Watts) <br /> (Watts) <br /> Parking Lot Asphalt 21970 0.025 549.2 630 0.2 157.5 707 <br /> Initial Wattage Allowance for Entire Site(Watts): 350 <br /> Total General Hardscape Allowance(Watts): 1057 <br /> J.LIGHTING ALLOWANCE:PER APPLICATION <br /> This section does not apply to this project. <br /> K.LIGHTING ALLOWANCE:SALES FRONTAGE <br /> This section does not apply to this project. <br /> L.LIGHTING ALLOWANCE:ORNAMENTAL <br /> This section does not apply to this project. <br /> Registration Number: Registration Date/Time: Registration Provider:Energysoft <br /> CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:2019.1.003 Report Generated:2022-01-3111:56:12 <br /> Schema Version:rev 20200601 <br /> 000 Oo 0 <br /> TSTI O rCn G7 0 A w <br /> C/) Ul N D � cf) Co j Ln c �• <br /> N■ Crr- zrn r �'�< CDr _ cWr � rOCa �Lf N <- Lrnl ;> <br /> z r JZ0m D 1 <br /> O Op . - <br /> C) Ozm < cv)Q (0pj , 0G) M S U 0 zE aM > Cn mb c C o0 :: n O w � 7MI� oD � Q <br /> �0 <br /> oflmr m n <br /> =1 <br /> pm I <br /> z N � 00 3 <br /> �0^60 y�jm etC/) W CD DCn - <br /> l J <br /> 1`0 X �p ,r <br /> IV <br /> i IV <br />
The URL can be used to link to this page
Your browser does not support the video tag.