My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SHELTON
>
9742
>
1600 - Food Program
>
PR0547446
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2022 4:37:49 PM
Creation date
3/7/2022 4:37:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0547446
PE
1608
FACILITY_ID
FA0026975
FACILITY_NAME
LOVE AND CONFECTION
STREET_NUMBER
9742
Direction
N
STREET_NAME
SHELTON
STREET_TYPE
RD
City
LINDEN
Zip
95236
CURRENT_STATUS
01
SITE_LOCATION
9742 N SHELTON RD
P_LOCATION
99
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
December 14, 2021 Lab ID : STK2156604 <br />Love and Confection Customer : 3-18990 <br />Quality Control - Inorganic <br />Constituent <br />Method <br />Date/m <br />Type <br />Units <br />Cone. <br />QC Data <br />DQO <br />Note <br />Wet Chem <br />Santa Paula, CA 93060 <br />Stockton, CA 95215 <br />Chico, CA 95926 <br />San Luis Obispo, CA 93401 <br />Visalia, CA 93291 <br />TEL: (805)392-2000 <br />TEL: (209)942-0182 <br />TEL: (530)343-5818 <br />Nitrate + Nitrite as <br />450ONO3F <br />11/19/21:213533vvh <br />Blank <br />mg/L <br />FAX: (559)734-8435 <br />ND <br /><0.2 <br />CA ELAP Certification No. 2670 <br />CA ELAP Certification No. 2775 <br />CA ELAP Certification No. 2810 <br />LCS <br />mg/L <br />11.22 <br />99.1% <br />80-120 <br />MS <br />mg/L <br />5.609 <br />99.7% <br />5-285 <br />(CH 2179462-001) <br />MSD <br />mg/L <br />5.609 <br />101% <br />5-285 <br />MSRPD <br />m <br />5.609 <br />1.1% <br />!CMA <br />450ONO3F <br />I1/19/21:218132vvh <br />CCB <br />mg"I <br />0.0120 <br />0.2 <br />CCV <br />mg/l <br />11.22 <br />98.7% <br />90-110 <br />CCB <br />m9/1 <br />-0.0320 <br />0.2 <br />CCV <br />mg1l <br />11.22 <br />98.1% <br />90-110 <br />Nitrate as NO3 <br />450ONO3F <br />11/19/21:213533vvh <br />Blank <br />I mg/L <br />ND <br /><0.9 <br />Nitrite as Nitrogen <br />450ONO3F <br />11/19/21:213536wh <br />Blank <br />mg/L <br />ND <br /><0.2 <br />LCS <br />mg/L <br />1.218 <br />102% <br />80-120 <br />MS <br />mg/L <br />0.6090 <br />101% <br />50-150 <br />(CH 2179462-001) <br />MSD <br />mg/L <br />0.6090 <br />103% <br />50-150 <br />MSRPD <br />mg/L <br />0.6090 <br />2.5% <br /><30 <br />450ONO3F <br />11/19/21:218130vvh <br />CCB <br />1119/1 <br />0.00700 <br />0.012 <br />CCV <br />mg/l <br />1.218 <br />101% <br />90-110 <br />CCB <br />mg/l <br />0.0110 <br />0.012 <br />CCV <br />m I <br />1.218 <br />101% <br />90-110 <br />Nitrite as NO2 <br />450ONO3F <br />11/19/21:213536vvh <br />Blank <br />m L <br />ND <br /><0.7 <br />Definition <br />CCV : Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />CCB : Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />Blank : Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br />LCS : Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte recovery. <br />MS : Matrix Spikes - A modem sample is spiked with a known amount of analyte. The recoveries are an indication of how that sample <br />matrix affects analyte recovery. <br />MSD : Matrix Spike Duplicate of MS/MSD pair - A random sample duplicate is spiked with a known amount of analyte. The recoveries <br />are an indication of how that sample matrix affects analyte recovery. <br />MSRPD : MS/MSD Relative Percent Difference (RPD) -The MS relative percent difference is an indication of precision for the preparation <br />and analysis. <br />ND : Non -detect - Result was below the DQO listed for the analyte. <br />DQO : Data Quality Objective - This is the criteria against which the quality control data is compared. <br />Page 5 of 5 <br />Corporate Offices & Laboratory <br />Office & Laboratory <br />Office & Laboratory <br />Office & Laboratory <br />Office & Laboratory <br />853 Corporation Street <br />2500 Stagecoach Road <br />563 E. Undo Avenue <br />3442 Empresa Drive, Suite D <br />9415 W. Goshen Avenue <br />Santa Paula, CA 93060 <br />Stockton, CA 95215 <br />Chico, CA 95926 <br />San Luis Obispo, CA 93401 <br />Visalia, CA 93291 <br />TEL: (805)392-2000 <br />TEL: (209)942-0182 <br />TEL: (530)343-5818 <br />TEL (805)783-2940 <br />TEL: (559)734-9473 <br />Env FAX: (805)5254172 / Aq FAX: (805)392-2063 FAX: (209)942-0423 <br />FAX: (530)343-3807 <br />FAX: (805)783-2912 <br />FAX: (559)734-8435 <br />CA ELAP Certification No. 1573 <br />CA ELAP Certification No. 1563 <br />CA ELAP Certification No. 2670 <br />CA ELAP Certification No. 2775 <br />CA ELAP Certification No. 2810 <br />
The URL can be used to link to this page
Your browser does not support the video tag.