SU0014796
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KENNEFICK
>
22150
>
2600 - Land Use Program
>
PA-2200025
>
SU0014796
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2022 1:38:30 PM
Creation date
3/10/2022 11:51:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0014796
PE
2627
FACILITY_NAME
PA-2200025
STREET_NUMBER
22150
Direction
N
STREET_NAME
KENNEFICK
STREET_TYPE
RD
City
ACAMPO
Zip
95220-
APN
01715001, -02
ENTERED_DATE
3/8/2022 12:00:00 AM
SITE_LOCATION
22150 N KENNEFICK RD
RECEIVED_DATE
8/3/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9 . At least 1 accessible route shall connect accessible buildings , accessible facilities , accessible <br /> elements , and accessible spaces that are on the same site . § 11 13 -206 . 2 . 2 <br /> 10 . At least 1 accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility , including mezzanines , which are <br /> otherwise connected by a circulation path . § 11 13 -206 . 2 . 4 <br /> 11 . Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code . Note that accessible parking spaces are required <br /> for each phase of the project . These parking space ( s ) shall be located as close as possible to <br /> the primary entrance to the building . <br /> 12 . Adequate sanitary facilities shall be provided for the facility , per the requirements of Chapter 4 <br /> of the California Plumbing Code . <br /> 13 . Pursuant to Section 422 . 4 of the California Plumbing Code , toilet facilities shall be accessible <br /> to employees at all times , should not be more than 500 feet from where employees are regularly <br /> employed and accessible by not more than one flight of stairs . The plans shall indicate the <br /> location of the toilet facilities and the travel distance from work areas . <br /> 14 . If the project includes landscaping , it will be required to comply with the Model Water Efficiency <br /> Landscape Ordinance requirements of the California Code of regulations , Title 22 , Division 2 , <br /> Chapter 2 . 7 <br /> j . FIRE PREVENTION BUREAU : The following California Fire Code ( CFC ) requirements will be <br /> applicable to the proposed project . The following conditions shall be addressed prior to submittal of a <br /> building permit application to the Building Inspection Division . <br /> 1 . CFC 507 Fire Protection Water Supply - Fire flow and hydrants shall be provided for the proposed <br /> project by the use of: CFC Appendix B . Static Water will be required . <br /> 2 . If Fire Protection Systems are required , they shall be installed according to the CFC , Chapter 9 <br /> and the appropriate standards and guides adopted in Chapter 35 of the California Building Code <br /> and the California Electrical Code . <br /> 3 , CFC , Section 503 Fire Apparatus Access Roads - Shall be provided as required by this section . <br /> 503 . 1 . 2 . A secondary access may be required . <br /> 4 . CFC , Section 906 Portable Fire Extinguishers — Provide portable fire extinguishers as required by <br /> this section . <br /> 5 . CFC , Section 506 Key Box - A Knox® Box shall be installed according to the local fire <br /> department ' s instructions . Make application for the key box at the fire district having jurisdiction of <br /> this project . If there is an electronically controlled access gate at this site a Knox® key switch will <br /> also be required . <br /> 6 . CFC , Section 5001 . 3 . 3 . 1 Properties of Hazardous Materials — A complete list of hazardous <br /> materials used , stored , or planned for use / storage at this site shall be provided . <br /> 7 . A complete review at building permit submittal will require compliance with applicable codes <br /> and ordinances . <br /> 8 . CFC , Section 105 Permits : Operational Permit ( s ) may be required prior to occupancy . <br /> PA-2200025 — Conditions of Approval 4 <br />