Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CUNHA DRAYING INC 1 1500 E MADRUGA RD, LATHROP March 08, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 719 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable <br /> containers. <br /> OBSERVATION: The facility failed to furnish a secondary means of containment, such as a dike or catchment <br /> basin, sufficient to contain the capacity of the largest single compartment or container with sufficient freeboard to <br /> contain precipitation. The following drums were observed with insufficient secondary containment: <br /> -Two 55 gallon drums of oil inside of a storage container <br /> -Four 55 gallon drums of oil located inside the shop(Page 9 of the SPCC plan states that the drums in the shop are <br /> provided secondary containment by the shop. Shop was observed with door ways that sloped outside and cracks in <br /> the concrete.) <br /> REGULATION GUIDANCE: (c)(11) Position or locate mobile or portable oil storage containers to prevent a <br /> discharge as described in§ 112.1(b). Except for mobile refuelers and other non-transportation-related tank trucks, <br /> you must furnish a secondary means of containment, such as a dike or catchment basin, sufficient to contain the <br /> capacity of the largest single compartment or container with sufficient freeboard to contain precipitation. <br /> CORRECTIVE ACTION: Position or locate all mobile containers to prevent discharge, and provide adequate <br /> secondary containment for mobile or portable oil storage tanks. Ensure the SPCC plan adequately discusses <br /> secondary containment for all portable containers. Provide proof or correction to the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by April 8, 2022. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209)468-3420. <br /> The following was observed during this inspection: <br /> -12,000 gallon diesel tank <br /> -550 gallon used oil tank <br /> -350 gallon motor oil tank <br /> -Six 55 gallon drums of oil <br /> The following was provided during this inspection: Schedule of free CUPA classes, Return to Compliance <br /> certification <br /> NOTE: Please updated APSA submittal on CERS with accurate information. Only 10,000 gallons of APSA <br /> regulated storage is reported in CERS. 13,200 gallons of APSA regulated storage was on site. One TIUGA <br /> was reported in CERS. No TIUGAs were observed during the inspection. <br /> FA0010537 PR0515717 SCO01 03/08/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 10 of 11 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />