Laserfiche WebLink
1500 East Madruga Road PR0515717 <br /> March 8, 2022 Program: APSA <br /> PHOTO 6: SPCC plan does not choose an industry standard for inspection and testing. <br /> LZZ :0 <br /> Cunha Trucking,Inc. <br /> J <br /> PeriodicTesti of the Inteerity of Aboveground Tanks <br /> 40 CFR 112.9 c <br /> The system is inspected monthly for leaks,stains and spills of Used Oil and#2 Diesel as <br /> required by the SPCC and CFR 40 112.7 Standards by trained staff of Cunha Trucking,Inc.,and <br /> I recorded on page 33.Periodic integrity testing is scheduled on five-year basis as specified by <br /> Industry Standards.The Industry Standards tester must be certified by the Steel Tank Institute or <br /> another Nationally recognized standard. <br /> Leakage from Internal Heating Coils <br /> 40 CFR 2 <br /> 8(cl(7l <br /> There are no internal heating coils within this system The applicable requirements of 40 <br /> CFR 112.8(c)(7)do not apply to this facility or SPCC Plan. <br /> Engineer or Update Containers to Avoid Discharee 40 CFR 112 8(cN8) <br /> Cunha Trucking,Inc.uses a visual tank gauge system consisting of a tank gauge that <br /> indicates the tank's volume in feet and inches. When the driver arrives on site and prior to <br /> unloading any oil product,they will verify tank space and insure that the oil product to be delivered <br /> will fit.The#2 Diesel fuel storage tank is equipped with a monitoring port system.If the driver is <br /> alerted of danger or overfill during delivery,the driver will cease all loading and secure the system <br /> New Motor Oil and Used Oil tanks are checked for product levels before additional fluids are <br /> added.All 55-gallon oil product drums are replaced with new 55-gallon oil product drums. <br /> Observe Effluent Discharge 40 CFR 112.8(c)(9) <br /> Cunha Trucking, Inc, does not employ a surface water effluent or water separation <br /> treatment system at this site.The requirements in 40 CRR 112.8(c)(9)are not applicable. <br /> Promptly Address Visible Discharee 40 CFR 112.8(c)(10) <br /> This is addressed within this Plan at 40 CFR 112.7(e). <br /> Mobile or Portable Oil Storage Containers 40 CFR 112.8(c)(11) <br /> Cunha Trucking,Inc.has several mobile and/or portable oil storage containers within their <br /> oil product management system.All the 55-gallon oil product tanks are mobile. <br /> 1 <br /> Facility Transfer Operations 40 CFR 112.8(d)(1)42),(3),(4),&(5) <br /> These items are addressed in 40 CFR 112.7(a)(3)(iii). <br /> 29 <br /> *Cary Reeves,LLC. <br /> Lydia Baker, SR. REHS Page 6 of 15 <br />