My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MADRUGA
>
1500
>
2800 - Aboveground Petroleum Storage Program
>
PR0515717
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2022 11:37:31 AM
Creation date
3/11/2022 11:12:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0515717
PE
2832
FACILITY_ID
FA0010537
FACILITY_NAME
CUNHA DRAYING INC
STREET_NUMBER
1500
Direction
E
STREET_NAME
MADRUGA
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
24141037
CURRENT_STATUS
01
SITE_LOCATION
1500 E MADRUGA RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of aboveground petroleum storage act violations that <br /> have not been addressed for CUNHA DRAYING INC as of May 27, 2022. <br /> Open violations from March 08, 2022 inspection <br /> Violation#604-Plan failed to include oil type and storage capacity for each container. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC)Plan failed to address the type of oil <br /> and storage capacity for portable and/or mobile containers. Page 9 of the SPCC plan states that, "Several 55-gallon <br /> oil product drums within the shop area and outside the shop." Two 55 gallon drums of oil were observed in the <br /> storage container outside the shop and four 55 gallon drums of oil were observed in the shop. <br /> REGULATION GUIDANCE: The SPCC plan shall include: (i)The type of oil in each fixed container and its storage <br /> capacity. For mobile or portable containers, either provide the type of oil and storage capacity for each container or <br /> provide an estimate of the potential number of mobile or portable containers,the types of oil, and anticipated <br /> storage capacities. <br /> CORRECTIVE ACTION: The SPCC Plan shall properly address the type and storage capacity of all fixed and <br /> portable and/or mobile containers, as required. Submit proof of correction to the EHD. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#610-Plan failed to adequately detail information and procedures for reporting a discharge. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC) Plan does not adequately discuss <br /> procedures for reporting a discharge. Page 18& 19 of the SPCC plan incorrectly names the phone number for the <br /> Environmental Health Department as"San Joaquin County Public Health Services Department." <br /> REGULATION GUIDANCE: The SPCC plan shall include: (vi)Contact list and phone numbers for the facility <br /> response coordinator, National Response Center, cleanup contractors with whom you have an agreement for <br /> response, and all appropriate Federal, State, and local agencies who must be contacted in case of a discharge as <br /> described in § 112.1(b). <br /> (4)Unless you have submitted a response plan under§ 112.20, provide information and procedures in your Plan to <br /> enable a person reporting a discharge as described in § 112.1(b)to relate information on the exact address or <br /> location and phone number of the facility;the date and time of the discharge,the type of material discharged; <br /> estimates of the total quantity discharged; estimates of the quantity discharged as described in§ 112.1(b);the <br /> source of the discharge; a description of all affected media;the cause of the discharge; any damages or injuries <br /> caused by the discharge; actions being used to stop, remove, and mitigate the effects of the discharge;whether an <br /> evacuation may be needed; and, the names of individuals and/or organizations who have also been contacted. <br /> CORRECTIVE ACTION: Ensure the SPCC Plan includes accurate procedures for reporting a discharge. Submit <br /> proof of correction to the EHD. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Page 3 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.