The following is an itemized list of aboveground petroleum storage act violations that <br /> have not been addressed for CUNHA DRAYING INC as of May 27 , 2022 . <br /> Open violations from March 08 , 2022 inspection <br /> Violation #712 - Failed to perform scheduled tank tests or inspections by appropriately qualified personnel . <br /> OBSERVATION : Facility failed to ensure that tanks are inspected and tested by an appropriately qualified person in <br /> accordance with industry standards . Page 24 of the SPCC plan requires monthly inspections of APSA regulated <br /> containers . No inspection records were available for review during the inspection . <br /> REGULATION GUIDANCE : 112 . 8 ( c) (6) Test or inspect each aboveground container for integrity on a regular <br /> schedule and whenever you make material repairs . You must determine , in accordance with industry standards , the <br /> appropriate qualifications for personnel performing tests and inspections , the frequency and type of testing and <br /> inspections , which take into account container size , configuration , and design ( such as containers that are : <br /> shop-built , field -erected , skid -mounted , elevated , equipped with a liner, double-walled , or partially buried ) . Examples <br /> of these integrity tests include , but are not limited to : visual inspection , hydrostatic testing , radiographic testing , <br /> ultrasonic testing , acoustic emissions testing , or other systems of non-destructive testing . You must keep <br /> comparison records and you must also inspect the container' s supports and foundations . In addition , you must <br /> frequently inspect the outside of the container for signs of deterioration , discharges , or accumulation of oil inside <br /> diked areas . Records of inspections and tests kept under usual and customary business practices satisfy the <br /> recordkeeping requirements of this paragraph . <br /> 112 . 7 (e ) Inspections , tests , and records . Conduct inspections and tests required by this part in accordance with <br /> written procedures that you or the certifying engineer develop for the facility . You must keep these written <br /> procedures and a record of the inspections and tests , signed by the appropriate supervisor or inspector, with the <br /> SPCC Plan for a period of three years . Records of inspections and tests kept under usual and customary business <br /> practices will suffice for purposes of this paragraph . <br /> CORRECTIVE ACTION : Immediately ensure that all tanks are inspected by an appropriately qualified person in <br /> accordance with industry standards . Submit proof of correction to the EHD . <br /> This violation was corrected ❑ This violation will be corrected by ( date ) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : P \ �� G`l r cl 7 db v S <br /> � c1- r k %k er t I Vt. S P tc'�k 0. S Ca{t +0% r.-er 5 ' ArL <br /> bne : V, LA _ 4; le ye- lo gel rlr ;,osc/ 4eA. v , k LA) c. <br /> A� v\ ,n ^ a ` tA^ cry a TjW 1 L^�S P fte cue S . <br /> Violation #718 - Failed to promptly correct visible discharges and/or remove accumulations of oil in diked <br /> areas . <br /> OBSERVATION : The facility failed to promptly correct visible discharges of oil . Approximately 6 inches of dark <br /> liquid was observed inside the secondary containment for the 550 used oil tank . <br /> REGULATION GUIDANCE : ( c) ( 10 ) Promptly correct visible discharges which result in a loss of oil from the <br /> container, including but not limited to seams , gaskets , piping , pumps , valves , rivets , and bolts . You must promptly <br /> remove any accumulations of oil in diked areas . <br /> CORRECTIVE ACTION : Immediately remove all oil accumulations in secondary containment and manage all <br /> wastes according to the California Code of Regulations Title 22 hazardous waste regulations , submit proof of <br /> correction to the EHD . <br /> Page 6 of 7 <br />