Laserfiche WebLink
SAN J 0 A Q I I I Irl Environmental Health Department <br /> CCUN Y <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CUNHA DRAYING INC 1 1500 E MADRUGA RD, LATHROP March 08, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 604 CFR 112.7(a)(3)(i)Plan failed to include oil type and storage capacity for each container. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC)Plan failed to address the type of oil <br /> and storage capacity for portable and/or mobile containers. Page 9 of the SPCC plan states that, "Several 55-gallon <br /> oil product drums within the shop area and outside the shop." Two 55 gallon drums of oil were observed in the <br /> storage container outside the shop and four 55 gallon drums of oil were observed in the shop. <br /> REGULATION GUIDANCE: The SPCC plan shall include: (i)The type of oil in each fixed container and its storage <br /> capacity. For mobile or portable containers, either provide the type of oil and storage capacity for each container or <br /> provide an estimate of the potential number of mobile or portable containers,the types of oil, and anticipated <br /> storage capacities. <br /> CORRECTIVE ACTION: The SPCC Plan shall properly address the type and storage capacity of all fixed and <br /> portable and/or mobile containers, as required. Submit proof of correction to the EHD. <br /> This is a minor violation. <br /> 610 CFR 112.7(a)(3vi), 112.7(a4)Plan failed to adequately detail information and procedures for reporting a discharge. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC) Plan does not adequately discuss <br /> procedures for reporting a discharge. Page 18& 19 of the SPCC plan incorrectly names the phone number for the <br /> Environmental Health Department as"San Joaquin County Public Health Services Department." <br /> REGULATION GUIDANCE: The SPCC plan shall include: (vi)Contact list and phone numbers for the facility <br /> response coordinator, National Response Center, cleanup contractors with whom you have an agreement for <br /> response, and all appropriate Federal, State, and local agencies who must be contacted in case of a discharge as <br /> described in § 112.1(b). <br /> (4)Unless you have submitted a response plan under§ 112.20, provide information and procedures in your Plan to <br /> enable a person reporting a discharge as described in § 112.1(b)to relate information on the exact address or <br /> location and phone number of the facility;the date and time of the discharge,the type of material discharged; <br /> estimates of the total quantity discharged; estimates of the quantity discharged as described in§ 112.1(b);the <br /> source of the discharge; a description of all affected media;the cause of the discharge; any damages or injuries <br /> caused by the discharge; actions being used to stop, remove, and mitigate the effects of the discharge;whether an <br /> evacuation may be needed; and, the names of individuals and/or organizations who have also been contacted. <br /> CORRECTIVE ACTION: Ensure the SPCC Plan includes accurate procedures for reporting a discharge. Submit <br /> proof of correction to the EHD. <br /> This is a minor violation. <br /> FA0010537 PR0515717 SCO01 03/08/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 6 of 11 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />