Laserfiche WebLink
❑ Step 12 continued : Reference information access cover for H-20, HS -20 <br />• Bolt lock type <br />• Must have holes to move access cover <br />01 CRATE HOLES <br />ARIS FOUNDRY <br />SALEM - NH - 03079 <br />TEL: 603-232-0406, FAX: 603-606-2450 <br />www.arisindustrial.com <br />❑ Step 12 continued: Set Rebar <br />arrangement for top slab. <br />DETAILS OF W <br />❑ Pour fresh concrete <br />❑ Cure concrete until <br />hardened. <br />❑ Step 12 continued : During final landscaping, seeding etc., be sure to pitch final <br />grade away from covers to sweep surface water away from treatment tank. <br />❑ Step 13: Fill out Warranty Activation Card (received with this Installation Manual) and return to <br />Fuji Clean USA to activate system Warranty. If this card cannot be found, please contact Fuji <br />Clean USA for voice or online Warranty activation. 207-406-2927. <br />