Laserfiche WebLink
0 <br /> SP-1200 & LT-1200 1200 585 2500 48 <br /> SP-1350 & LT-1350 1350 657 2750 54 <br /> SP-1500 & LT-1500 1500 729 3000 60 <br /> [3] Maximum loading rate of 3 gallons per square foot onto the Eljen GSF Media, while <br /> maintaining a maximum hydraulic loading to the underlying soil system as 2 gallons <br /> per square foot per day. The GSF Advanced Treatment (AT) Systems can be installed in <br /> a bed configuration with a minimum spacing along both sides of modules of 6 inches. <br /> A minimum of 6 inches of Specified Sand is placed at the beginning and end of each row. <br /> [4] Minimum requirement of 6 inches of system sand below the GSF Wastewater Treatment System. <br /> [5] While the GSF Advanced Treatment (AT) Systems includes design specifications similar to a <br /> dispersal field, the scope of the NSF/ANSI Standard 40 Class I Certification does NOT <br /> include management methods for the treated effluent discharged from the system. <br /> [6] The GSF Advanced Treatment (AT) Systems are approved with the modules A66 (6 inch <br /> height) , A42 (7 inch height) , and B43 (7 inch height, 36 inches wide) . <br /> Note: Additions shall not be made to this document without prior evaluation and acceptance by NSF. <br /> 2 of 2 <br /> 3L030 <br /> 789 N.Dixboro Road,Ann Arbor,Michigan 48105-9723 USA <br /> 1-800-NSF-MARK/734-769-8010 <br /> www.nsforg <br />