My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
16900
>
2800 - Aboveground Petroleum Storage Program
>
PR0528139
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2022 10:53:21 AM
Creation date
3/21/2022 2:47:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0528139
PE
2832
FACILITY_ID
FA0007697
FACILITY_NAME
SAFEWAY DISTRIBUTION CENTER
STREET_NUMBER
16900
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
20943001
CURRENT_STATUS
01
SITE_LOCATION
16900 W SCHULTE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SAFEWAY DISTRIBUTION CENTER 1 16900 W SCHULTE RD,TRACY March 07, 2022 <br /> SPCC Plan Requirements for Onshore Facilities(excluding production facilities) <br /> 719 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable containers ■V ❑R ❑COS <br /> 720 CFR 112.8(d)(1) Failed to take corrective action on buried piping when exposed for any reason ❑V ❑R ❑COS <br /> 721 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ❑V ❑R ❑COS <br /> 722 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 723 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 724 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ■V ❑R ❑COS <br /> 725 CFR 112.8(d)(4) Failed to conduct integrity and leak testing on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> 727 CFR 112.7(a)(1), Plan failed to adequately describe overfill prevention methods for each container ❑V ❑R ❑COS <br /> 112.8(c)(8) <br /> jk Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandon ment/lIlegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 604 CFR 112.7(a)(3)(i)Plan failed to include oil type and storage capacity for each container. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC)Plan failed to address the type of oil <br /> and storage capacity for each fixed container. One 275-gallon Automatic TransFluid observed in the truck repair <br /> shop was observed on site that was not addressed in the plan. <br /> REGULATION GUIDANCE: The SPCC plan shall include: (i)The type of oil in each fixed container and its storage <br /> capacity. For mobile or portable containers, either provide the type of oil and storage capacity for each container or <br /> provide an estimate of the potential number of mobile or portable containers,the types of oil, and anticipated <br /> storage capacities. <br /> CORRECTIVE ACTION: The SPCC Plan shall properly address the type and storage capacity of all fixed and <br /> portable and/or mobile containers, as required. Submit proof of correction to the EHD. <br /> This is a minor violation. <br /> FA0007697 PR0528139 SCO01 03/07/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 4 of 10 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.