ELECTRICAL CONSUMERS SCHEDULEEQUIPMENT DESCRIPTIONMANUFACTURERPLUGHEIGHTAFFTYPEAMPSVOLTSPHASEMODELWALK-IN COOLERJ-BOXFREEZER-2-DOOR XNEMA 5-1510.51201ICE MACHINE + ICE BIN WITH LIFT DOORX131201FRYERX.7120VERTICAL BROILERSX1.01201EXHAUST HOODXJ-BOXEXHAUST FANXJ-BOXMAKE-UP AIRXJ-BOXANSUL FIRE SYSTEMXJ-BOXMEGA TOP SALAD/SANDWICHX3.31201CLEVELAND TILT PAN -40 GALLONXNEMA L5-20P12.51201DOUBLE PANNI STATION PLUS BASE TABLEX4.21201WORK TOP FREEZERX5.31201WORK TOP FREEZERX7.81201XNEMA 5-15NEMA 5-15NEMA 5-15NEMA 5-15NEMA 5-15NEMA 5-15TANDOORI OVENX252083NEMA 5-50P11334316ICECREAM FREEZER131201373643399X252083NEMA 5-50P10ROTISSERIE CHICKEN OVEN7,8X252083NEMA 5-50P4MULTI-COOK OVEN UNDERCOUNTER FREEZER12/BXNEMA 5-1510.51201BACK BAR REFRIGERATORXNEMA 5-1510.5120111/BSHEET TITLE:DRAWING SHEET NO:COPYRIGHT:CHECKED BY:DRAWN BY:DATE:CAD FILE:PROJECT NO:ISSUE:MARKDATEDESCRIPTIONCordell Constructions, Larry Johnson; Phone: 408-221-8126ELECTRICAL NOTESE000The Oxford Kitchen andGastropub110W OAK STREETLODI, CALIFORNIA,9210ELECTRICAL SPECIFICATIONA-1SMOCELECTRICAL SYMBOLSEXIT LIGHTING FIXTURE ON EMERGENCY CIRCUITRY ARROWS ASINDICATED. FIXTURES TO COMPLY WITH LOCAL JURISDICTIONREQUIREMENTS - SEE SCHEDULEMOTOR RATED SWITCH WITH THERMAL OVERLOADWALL MOUNTED DUPLEX RECEPTACLE - 2P, 3W, 20A, 125V,GROUNDED (HUBBELL #5362). COLOR OF DEVICE AND FACE PLATESHALL BE AS SELECTED BY THE ARCHITECT. MOUNTING HEIGHTTOCENTERLINE ABOVE FINISHED FLOOR 18” UON.WALL MOUNTED DOUBLE DUPLEX RECEPTACLE - 2P, 3W, 20A,125V,GROUNDED (HUBBELL #5362). COLOR OF DEVICE AND FACE PLATESHALL BE AS SELECTED BY THE ARCHITECT. MOUNTING HEIGHTTO CENTERLINE ABOVE FINISHED FLOOR 18” UON.2-HEAD BATTERY LIGHTING UNITJUNCTION BOX - CEILING OR WALL MOUNTEDSINGLE POLE SWITCH - ARROW HART #1991. COLOR OFDEVICE AND FACE PLATE SHALL BE WHITE.MOUNTING HEIGHT TO CENTERLINE ABOVE FINISHED FLOOR 4' - 0".THREE WAY SWITCH . COLOR OF DEVICE AND FACE SHALL BEWHITEMOUNTING HEIGHT TO CENTERLINE ABOVE FINISHED FLOOR 4' - 0"SMOKE DETECTORSPECIAL OUTLET. COORDINATE EXACT NEMA CONFIGURATIONSOF OUTLET WITH OWNER’S REPRESENTATIVE AND EXACTMOUNTING HEIGHT PRIOR TO ROUGH-IN.STJJSS3SDABBREVIATIONSAAMPEREAFF ABOVE FINISHED FLOORAICAMPERES INTERRUPTING CAPACITY C CONDUIT/EMTC/BCIRCUIT BREAKERECEMPTY CONDUIT/EMT. PROVIDE PULL WIREEMT ELECTRICAL METALLIC TUBINGGGROUNDHPHORSEPOWERMCB MAIN CIRCUIT BREAKERMTD MOUNTEDNIC NOT IN CONTRACTKWKILOWATTSPPOLEPNLPANELRRECESSEDLF LINEAR FEETSSURFACEUONUNLESS OTHERWISE NOTEDVVOLTWWIREMTD MOUNTEDOC ON CEILINGEG EQUIPMENT GROUNDIG ISOLATED GROUNDFACP FIRE ALARM CONTROL PANELELECTRICAL SYMBOLSPANELBOARD - SEE SCHEDULE. MOUNTING HEIGHT TO CENTERLINEABOVE FINISHED FLOOR 6' - 0 " TO TOP.MOTOR CONNECTION - HORSEPOWER AS INDICATED, FRACTIONALIF NO NOTED.DISCONNECT SWITCH - SEE DRAWING FOR VOLTAGE, POLES ANDAMPERAGE RATING.HOMERUN TO PANELBOARD. NUMBER OF ARROWHEADS INDICATENUMBER OFCIRCUITS. NUMERALS AND LETTERS ADJACENT TO ARROWHEADSINDICATEASSIGNED PANEL AND CIRCUIT NUMBERS. SEE PANEL SCHEDULEFOR AMPERAGERATING OF EACH CIRCUIT BREAKER AND CONDUCTOR SIZESCIRCUITRY INSTALLED CONCEALED IN WALL OR ABOVE CEILING.NUMBEROF TICKS INDICATE NUMBER OF CONDUCTORS. IF NO TICKS MARKINDICATE 2(TWO) CONDUCTORS IN RACEWAY. SEE PANEL SCHEDULE FORCONDUCTOR SIZES.OCCUPANCY SENSOR FOR THE SMALL INDIVIDUAL OFFICE, +48”A.F.F. MOTION SENSOR SHALL BE AS MANUF. BY WATTSTOPPERWITH TIME DELAY SHALL BESET @ LESS THAN 15 MINUTES WATTSTOPPER CAT# DW-100COLOR TO BE SELECTED BY THE ARCHITECT.OCCUPANCY SENSOR, CEILING MOUNTED AS MANUF. BYWATTSTOPPER.SWITCH BANKDAYLIGHT SENSORDLA. GENERAL1. THE ENTIRE ELECTRICAL INSTALLATION SHALL CONFORM TO THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND LOCAL JURISDICTION REQUIREMENTS. B. SHOP DRAWINGS 1. PROVIDE SHOP DRAWINGS FOR THE FOLLOWING ITEMS: LIGHTING FIXTURES, OCCUPANCY SENSORS , RECEPTACLES AND FIRE ALARM DEVICES C. EQUIPMENT AND DEFINITIONS 1. ALL ELECTRICAL EQUIPMENT SHALL BEAR THE UNDERWRITER’S LABORATORIES LABEL. 2. UNLESS SPECIFICALLY NOTED ON THE PLANS ALL CIRCUITRY, EQUIPMENT, DEVICES, ETC., NOT NOTED EXISTING TO REMAIN OR TO BE RELOCATED SHALL BE NEW. D. JUNCTION BOXES LABELING REQUIREMENTS1. ALL JUNCTION BOXES FOR BRANCH CIRCUITRY SHALL BE CLEARLY LABELED WITH PANEL DESIGNATION AND CIRCUIT NUMBERS. E. PANELBOARDS 1. PROVIDE A TYPED CIRCUIT DIRECTORY FOR THE ENTIRE PANELBOARD REVISED UNDER THIS CONTRACT.2. CONTRACTOR SHALL PHASE BALANCE ALL PANELBOARDS AS NECESSARY.3. THE BRANCH CIRCUITS SHOWN FOR ITEMS SERVED AS INDICATED. CONTRACTOR SHALL FIELD COORDINATE ALL BRANCH CIRCUITS ACCORDINGLY. 4. BRANCH CIRCUITRY SHOWN ON FLOOR PLAN CONNECTED TO A DESIGNATED CIRCUIT EXACT POSITION OF CIRCUIT BREAKER SHALL BE AFTER REMOVAL OF OUTLETS UNDER DEMOLITION. CONTRACTOR SHALL UTILIZE ALL C/B’S BECOMING SPARE F. CIRCUIT BREAKERS1. ALL NEW CIRCUIT BREAKERS TO BE INSTALLED IN NEW PANELS SHALL BE BOLT-ON TYPE. G. SWITCHES, RECEPTACLES, TELEPHONE OUTLETS AND DATA OUTLETS 1. WHERE TWO OR MORE DEVICES OF THE SAME VOLTAGE ARE SHOWN TOGETHER ON THE PLANS, A GANGED PLATE SHALL BE USED. DEVICES OF DIFFERENT VOLTAGES SHALL BE SEPARATED HORIZONTALLY BY 6” BUT SHALL BE HORIZONTALLY OR VERTICALLY ALIGNED. 2. ALL RECEPTACLES, TELEPHONE, AND DATA OUTLETS SHOWN ON A WALL BACK TO BACK SHALL BE OFFSET A MINIMUM OF 6" HORIZONTALLY. H. LIGHTING FIXTURES 1. COORDINATE ALL LIGHTING FIXTURES WITH SPRINKLERS, MECHANICAL EQUIPMENT AND ARCHITECTURAL CEILING PLAN TO AVOID CONFLICT. GRID LAYOUT ON PLANS IS APPROXIMATE, ADJUST AND COORDINATE LIGHTING FIXTURES IN FIELD PER ARCHITECTS REFLECTED CEILING PLAN. 2. PROVIDE FINISHED FRAMES FOR ALL RECESSED LIGHTING FIXTURES, TYPE TO BE COORDINATE ALL FIXTURE TYPES WITH CEILING SYSTEM BEFORE ORDERING FIXTURES. PROVIDE ALL MOUNTING ATTACHMENTS FOR A COMPLETE INSTALLATION. LIGHTING FIXTURES SHALL BE SUPPORTED PER LOCAL CODE REQUIREMENTS. 3. ALL NEW LIGHTING FIXTURES SHALL BE INSTALLED COMPLETE WITH LAMPS. SEE LIGHTING FIXTURE SCHEDULE FOR LAMPS AND TYPE OF BALLASTS REQUIREMENTS AND/OR PLANS. 4. COLOR OF LIGHTING FIXTURES SHALL BE AS SELECTED BY THE ARCHITECT.I. BRANCH CIRCUITRY AND FEEDER 1. ALL CONDUCTORS SHALL BE COPPER.2. ALL BRANCH CIRCUITRY AND FEEDER SHALL COMPLY WITH THE UTEST NATIONAL ELECTRICAL CODE (N.E.C.) LOCAL JURISDICTION AND LOCAL STATE CODE REQUIREMENTS. THE FOLLOWING ARE SOME ACCEPTABLE WIRING METHOD REQUIREMENTS.J. INDOOR USE BRANCH CIRCUITRY 1. METAL CLAD CABLE (MC CABLE) IS PERMITTED TO SERVE RECEPTACLES/LIGHTING AND OTHER EQUIPMENT LOAD. METAL CLAD CABLE MC IS PERMITTED TO RUN CONCEALED AREA SUCH AS CEILING SPACE AND FINISHED WALL AREA ONLY. CONTRACTOR SHALL FOLLOW ELECTRICAL SYMBOLS LIST ALL HOMERUN BRANCH CIRCUITRY FOR THE INDOOR EQUIPMENT SHALL BE INSTALLED IN EMT K. GENERAL NOTES IN REGARDS TO BRANCH CIRCUITRY AND FEEDER 1. USE OF ALUMINUM CONDUIT SHALL NOT BE PERMITTED.2. ALL BRANCH CIRCUITRY AND FEEDERS SHALL BE RUN CONCEALED.3. ALL CIRCUITRY RUNS ARE DIAGRAMMATIC. THE CONTRACTOR SHALL DETERMINE IN FIELD THE MOST SUITABLE ROUTES. 4. MINIMUM SIZE EMT OR CONDUIT SHALL BE 3/4’’. UNLESS MULTIPLE HOMERUN CIRCUITS REQUIRES URGER SIZE CONDUIT. 5. NO NONMETALLIC CONDUIT SHALL BE USED FOR BRANCH CIRCUIT WORK ABOVE GRADEL. WIRE AND CABLE 1. FEEDERS: FEEDER SHALL BE ALUMINUM . INSULATION SHALL BE THW OR THHN/THWN. 2. COLOR CODE: ALL WIRING SHALL BE COLOR CODED THROUGHOUT AS PER N.E.C. REQUIREMENTS. 3. ALL CONDUCTORS SHALL BE COPPER, MINIMUM #2 AWG. 4. ALL RECEPTACLES, LIGHTING FIXTURES, MOTORS, ETC.. SHALL BE GROUNDED PER N.E.C. ALL RECEPTACLE CIRCUITS SHALL CONTAIN A #12 INSULATED GROUND CONDUCTORS5. RUN MULTIPLE HOMERUNS TO ALTERNATELY NUMBERED PANELBOARD CIRCUITS (I.E., 1,3,5) SERVING LIGHTING, GENERAL RECEPTACLES, AND MOTORS. ANY CIRCUITS SERVING, ISOLATED GROUND RECEPTACLES OR RECEPTACLES SERVING COMPUTER EQUIPMENT, WHEN THE CONTRACTOR RUN CIRCUITRY IN MULTIPLE HOMERUNS. CONTRACTOR SHALL OVERSIZE THE NEUTRAL CONDUCTOR TO A MINIMUM 200% OF THE CAPACITY OF PHASE CONDUCTORS SIZE THE EMT/CONDUIT ACCORDINGLY WHERE NECESSARY. 6. ALL EMPTY RACEWAYS SHALL CONTAIN A DRAG WIRE. EMPTY RACEWAYS 2” OR LARGER IN SIZE SHALL HAVE A MAXIMUM OR 2 - 90 DEGREES BENDS PER RUN. WHERE REQUIRED, PROVIDE PULL BOXES PER N.E.C. REQUIREMENTS. 7. FINAL CONNECTION TO ALL MOTORS OR VIBRATING EQUIPMENT SHALL BE WITH FLEXIBLE CONDUIT OR LIQUID-TIGHT FLEXIBLE CONDUIT FOR OUTDOOR. 8. ALL 120 VOLT CIRCUIT HOMERUNS WHICH ARE OVER 100 LINEAR FEET SHALL BE A MINIMUM OF #10 CONDUCTORS OR AS SHOWN ON THE PLANS. 9. EXPOSED AND CONCEALED CIRCUITRY SHALL BE RUN TIGHT TO CEILING SLAB IN A NEAT WORKMANLIKE MANNER. ALL RUNS SHALL BE PARALLEL OR PERPENDICULAR TO BUILDING WALL. M. GROUNDING1. PROVIDE GROUND TO ALL DEVICES PER N.E.C. REQUIREMENTS.2. PROVIDE SERVICE GROUND CONDUCTORS SIZE PER NEC REQUIREMENTS.3. PROVIDE EQUIPMENT GROUND CONDUCTORS SIZE PER NEC REQUIREMENTS. N. FIRE SEALANT MATERIALS1. ANY PENETRATION TO THE FIRE WALLS. CONTRACTOR SHALL PROVIDE FIRE SEALANT MATERIALS AT EVERY POINT WHERE OCCURRED. FIRE SEALANT MATERIALS MANUFACTURER SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR TO APPLICATION. O. WORK SCHEDULE1. COORDINATE WITH ARCHITECT AND/OR OWNER’S REPRESENTATIVE FOR WORK SCHEDULE REQUIREMENTS P. FINAL TESTING1. AT THE TIME OF FINAL INSPECTION AND TEST, ALL CONNECTIONS AND TERMINATIONS AT PANELBOARDS, DEVICES, EQUIPMENT, AS WELL ALL SPLICES MUST BE ALL COMPLETED. EACH BRANCH CIRCUIT AND ITS RESPECTIVE CONNECTED EQUIPMENT MUST TEST FREE OF SHORT CIRCUIT COMPLETION OF THE WORK, CLEAN AND POLISH ALL EXPOSED SURFACES IN ACCORDANCE WITH THE MANUFACTURER’S RECOMMENDATIONS.