Laserfiche WebLink
8'-0" <br />ELEVATION HEIGHT MARKER: <br />LEVEL NAME <br />SPOT ELEVATION HEIGHT MARKER <br />AD.00 <br />1 SIM <br />DETAIL REFERENCE: <br />KEYNOTE REFERENCE: <br />SEQUENCE NUMBER <br />CSI DIVISION NUMBER <br />LEVEL <br />8'-0" <br />HEIGHT <br />101 <br />ROOM NAME & REFERENCE NUMBER <br />DOOR REFERENCE NUMBER <br />(SEE DOOR SCHEDULE) <br />10.1 <br />DETAIL NUMBER <br />SHEET NUMBER <br />WALL TYPE REFERENCE NUMBER <br />INTERIOR ELEVATION <br />DETAIL NUMBER <br />SHEET NUMBER <br />A10.00 <br />1 <br />1 <br />1 <br />1 <br />ROOM <br />NAME <br />101 <br />M4.1 <br />MATERIAL TYPE (M) MTL, (W) WD <br />MATERIAL WIDTH <br />WALL HEIGHT (SEE WALL LEGEND) <br />LDG LANDING <br />LT LIGHT <br />MEMB MEMBRANE <br />MFR MANUFACTURER <br />MIN MINIMUM <br />MISC MISCELLANEOUS <br />MO MASONRY OPENING <br />MTD MOUNTED <br />MTL METAL <br />(N) NEW <br />NIC NOT IN CONTRACT <br />NO. NUMBER <br />NTS NOT TO SCALE <br />O.P. OVERFLOW PIPE <br />OA OVERALL <br />OC ON CENTER <br />OD OUTSIDE DIAMETER <br />OPG OPENING <br />OPP OPPOSITE <br />PERM PERIMETER <br />PG PAINT GRADE <br />PLAM PLASTIC LAMINATE <br />PLAS PLASTER <br />PR PAIR <br />PT PAINT <br />R RISER <br />RAD RADIUS <br />RCP REFLECTED CEILING PLAN <br />RD ROOF DRAIN <br />REF REFRIGERATOR <br />REINF REINFORCED <br />REQD REQUIRED <br />RESIL RESILIENT <br />RTNG RATING <br />RO ROUGH OPENING <br />RTU ROOF TOP UNIT (MECH) <br />SAFB SOUND ATTENUATION FIBER <br />BATT <br />SC SCUPPER <br />SCD SEE CIVIL DRAWINGS <br />SCHED SCHEDULE <br />SEAL SEALANT <br />SECT SECTION <br />SED SEE ELECTRICAL DRAWINGS <br />SF SQUARE FOOT <br />SFPD SEE FIRE PROTECTION <br />DRAWINGS <br />SHT SHEET <br />SIM SIMILAR <br />SLD SEE LANDSCAPE DRAWINGS <br />SMD SEE MECHANICAL DRAWINGS <br />SPD SEE PLUMBING DRAWINGS <br />SPEC SPECIFICATION <br />SQ SQUARE <br />SS STAINLESS STEEL <br />SSD SEE STRUCTURAL DRAWINGS <br />STD STANDARD <br />STL STEEL <br />STOR STORAGE <br />SUSP SUPSPENDED <br />SYM SYMMMETRICAL <br />T TREAD <br />THK THICK <br />THR THRESHOLD <br />TO TOP OF <br />TYP TYPICAL <br />UC UNDERCUT <br />UNFIN UNFINISHED <br />UNO ULNESS NOTED OTHERWISE <br />UON UNLESS OTHERWISE NOTED <br />VCT VINYL COMPOSITION TILE <br />VIF VERIFY IN FIELD <br />VTR VENT TERMINATION PIPE <br />VWC VINYL WALL COVERING <br />W/ WITH <br />W/O WITHOUT <br />WC WATERCLOSET <br />WIN WINDOW <br />WP WATERPROOF <br />WSCT WAINSCOT <br />WT WEIGHT <br />ACOUS ACOUSTICAL <br />ACT ACOUSTICAL CEILING TILE <br />AD AREA DRAIN <br />ADJ ADJUSTABLE <br />AFF ABOVE FINISH FLOOR <br />ALT ALTERNATE <br />ARCH ARCHITECT <br />B.O. BOTTOM OF <br />BD BOARD <br />BET BETWEEN <br />BLKG BLOCKING <br />BM BEAM <br />BOT BOTTOM <br />BRKT BRACKET <br />BUR BUILT UP ROOF <br />C.G. CORNER GUARD <br />CAB CABINET <br />CALK CAULKING <br />CER CERAMIC <br />CJ CONTROL JOINT <br />CLOS CLOSET <br />CLR CLEAR <br />CO CASED OPENING <br />COL COLUMN <br />CONC CONCRETE <br />CONT CONTINUOUS <br />CPT CARPET <br />CT CERAMIC TILE <br />CTR CENTER <br />DEMO DEMOLISH <br />DIA DIAMETER <br />DIM DIMENSION <br />DN DOWN <br />DR DOOR <br />DS DOWNSPOUT <br />DWG DRAWING <br />(E) EXISTING <br />EA EACH <br />EJ EXPANSION JOINT <br />ELEV ELEVATION <br />EMER EMERGENCY <br />ENCL ENCLOSURE <br />EOS EDGE OF SLAB <br />EQ EQUAL <br />EW EACH WAY <br />F.O. FACE OF <br />FA FIRE ALARM <br />FAP FIRE ANNUNCIATOR PANEL <br />FD FLOOR DRAIN <br />FE FIRE EXTINGUISHER <br />FEC FIRE EXTINGUISHER CABINET <br />FH FIRE HYDRANT <br />FIN FINISH <br />FRP FIBER-REINFORCED PLASTIC <br />FT FOOT OR FEET <br />FUR FURRING <br />G.S.M. GALVANIZED SHEET METAL <br />GAL GALLON <br />GALV GALVANIZED <br />GB GRAB BAR <br />GC GENERAL CONTRACTOR <br />GL GLASS <br />GND GROUND <br />GWB GYPSUM BOARD <br />GYP. GYPSUM <br />H.W.H. HOT WATER HEATER <br />HDWD HARDWOOD <br />HM HOLLOW METAL <br />HT HEIGHT <br />ID INSIDE DIAMETER <br />INSUL INSULATION <br />INT INTERIOR <br />JST JOIST <br />JT JOINT <br />LAM LAMINATE <br />LAV LAVATORY <br />T24.2 Unnamed <br />GENERAL <br />G0.00 COVER SHEET, PROJECT DATA, GENERAL <br />NOTES, SYMBOLS & ABBREVATIONS <br />G1.00 CAL GREEN CHECKLIST <br />G1.01 CAL GREEN CHECKLIST <br />G1.02 CAL GREEN CHECKLIST <br />G2.00 LIFE SAFETY PLAN <br />ARCHITECTURAL <br />A1.00 SITE PLAN <br />A2.00 DEMOLITION FLOOR PLAN <br />A3.10 FLOOR DIMENSION PLAN & <br />ANNOTATION PLAN <br />A4.10 REFLECTED CEILING PLAN <br />A8.01 INTERIOR ELEVATIONS <br />A9.00 SCHEDULES <br />AD.01 DETAILS <br />AD.02 DETAILS <br />MECHANICAL <br />M0 MECHANICAL SCHEDULES, NOTES, AND <br />DETAILS <br />M1 MECHANICAL FLOOR PLANS <br />PLUMBING <br />P0 PLUMBING SCHEDULES, NOTES, AND <br />DETAILS <br />P1 PLUMBING FLOOR PLANS <br />T24.1 TITLE 24 DOCUMENTATION <br />ELECTRICAL <br />E1.00 POWER FLOOR PLAN & SCHEDULES <br />REFERENCE DESCRIPTION INTERPRETATION <br />DESCRIPTION <br />SCOPE REMODEL OF (E) RESTAURANT <br />SPACE TO A NEW BOBA/ICE <br />CREAM PARLOR. SCOPE OF <br />WORK TO INCLUDE NEW SERVICE <br />& DINING COUNTERS, <br />INSTALLATION OF NITROGEN <br />TANKS & PIPING, NEW <br />ELECTRICAL CONNECTIONS FOR <br />NECESSARY EQUIPMENT, AND <br />UPDATED CEILING AND ROOM <br />FINISHES. <br />LOCATION 5757 PACIFIC AVE, SUITE A-130 <br />STOCKTON, CA 95207 <br />ZONING LARGE SCALE COMMERCIAL <br />APN 108-13-24 <br />SPECIAL USE <br />PERMIT <br />GENERAL INFORMATION <br />1ST FLOOR AREA 979 SF <br />ACTUAL BUILDING HEIGHT XX'-X" <br />ACTUAL NUMBER OF STORIES 2 STORIES <br />OCCUPANCY <br />CBC 303.1 GROUP -B <br />CBC 508.3 AUTOMATIC FIRE SPRINKLERS YES <br />CBC TABLE 601 CONSTRUCTION TYPE V-B <br />TITLE 19 CCR, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS <br />TITLE 24 CCR, PART 1 - 2019 BUILDING STANDARDS ADMINISTRATIVE CODE <br />TITLE 24 CCR, PART 2 - 2019 CALIFORNIA BUILDING CODE, VOL. 1 & 2 (CBC) <br />(2015 IBC, AS AMENDED BY CA) <br />TITLE 24 CCR, PART 3 - 2019 CALIFORNIA ELECTRICAL CODE (CEC) (2014 NEC, <br />AS AMENDED BY CA) <br />TITLE 24 CCR, PART 4 - 2019 CALIFORNIA MECHANICAL CODE (CMC) (2015 <br />IAPMO UMC, AS AMENDED BY CA) <br />TITLE 24 CCR, PART 5 - 2019 CALIFORNIA PLUMBING CODE (CPC) (2015 IAPMO <br />UPC, AS AMENDED BY CA) <br />TITLE 24 CCR, PART 6 - 2019 CALIFORNIA ENERGY CODE <br />TITLE 24 CCR, PART 9 - 2019 CALIFORNIA FIRE CODE (CFC) (2015 IFC, AS <br />AMENDED BY CA) <br />TITLE 24 CCR, PART 11 - 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />TITLE 24 CCR, PART 12 - 2019 CALIFORNIA REFERENCED STANDARDS (PARTIAL <br />LIST - SEE CBC CH. 35 AND CFC CH. 80) <br />NITRO BOBA <br />5757 PACIFIC AVE, STOCKTON, CA <br />PROPOSED PROJECT TYPE <br />FOR <br />VY VY <br />ADDRESS: <br />PHONE: <br />CONTACT: <br />EMAIL: <br />VY VY <br />5757 Pacific Ave, Suite A-130 <br />Stockton, CA 95207 <br />Vy Vy <br />vyhoangvy1978@yahoo.com <br />OWNER: <br />ADDRESS: <br />PHONE: <br />CONTACT: <br />EMAIL: <br />TBD <br />CONTRACTOR: <br />ADDRESS: <br />PHONE: <br />CONTACT: <br />EMAIL: <br />GDMG ENGINEERING INC. <br />212 WEST PINE ST. SUIT #4 <br />LODI CA, 95240 <br />(209) 367-0899 <br />GREG DAVIS <br />gdmdengrinc@sbcglobal.net <br />MECHANICAL ENGINEER: <br />ADDRESS: <br />PHONE: <br />CONTACT: <br />EMAIL: <br />LDA Partners, Inc. <br />222 Central Ct. <br />Stockton, CA 95204 <br />209.943.0405 <br />Carolyn Natividad <br />cnatividad@ldapartners.com <br />ARCHITECT: <br />ADDRESS: <br />PHONE: <br />CONTACT: <br />EMAIL: <br />HCS ENGINEERING <br />4512 FEATHER DR, SUITE F <br />STOCKTON CA, 95219 <br />(209) 478-8270 <br />RICHARD SMITH <br />richard@hcs-eng.com <br />ELECTRICAL ENGINEER: <br />ADDRESS: <br />PHONE: <br />CONTACT: <br />EMAIL: <br />GDMG ENGINEERING, INC. <br />212 WEST PINE ST. SUITE #4 <br />LODI CA, 95240 <br />(209) 367-0899 <br />GREG DAVIS <br />gdmdengrinc@sbcglobal.net <br />PLUMBING ENGINEER: <br />PLAN CHECK <br />12-24-2020 <br />GENERAL NOTES <br />CONTACTS PROJECT DATA SHEET INDEX <br />APPLICABLE CODES <br />SYMBOLS LEGEND <br />ABBREVIATIONS July 20____ <br />C33148CAROLYNMOEA N <br />A <br />T <br />I <br />VI <br />DADLICEN S E D A RC <br />HI <br />T <br />ECTSTAT <br />E <br />OF C A L IF O RNIAChecked By: <br />Drawn By: <br />Project No.: <br />LDA Partners, Inc <br />Designers & Architects <br />222 Central Court <br />Stockton, CA 95204 <br />209.943.0405 <br />www.ldapartners.com <br />Client: <br />Architect: <br />Project: <br />NOR FOR CONSTRUCTION <br />12/23/2020 4:31:30 PMCOVER SHEET, PROJECT DATA, <br />GENERAL NOTES, SYMBOLS & <br />ABBREVATIONS <br />G0.00 <br />BB <br />CN <br />###-#-## <br />PLAN CHECK 1 <br />12/24/2020 <br />NITRO BOBA TI <br />5757 PACIFIC AVE. <br />Mr. Vy H Vy & Mrs. Jenny <br />Pham <br />###.###.#### <br />STOCKTON, CA <br />SUITE A130, STONE <br />CREEK VILLAGE <br />STOCKTON, CA <br />1. ON-SITE VERIFICATION OF ALL DIMENSIONS AND DETAILS SHALL BE THE <br />RESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACH <br />SUBCONTRACTOR FOR HIS INDIVIDUAL WORK. THE OWNER OR ARCHITECT <br />SHALL BE NOTIFIED IF ANY DISCREPANCIES ARE FOUND PRIOR TO <br />COMMENCING ANY WORK. THE RESPONSIBILITY FOR WORK COMPLETED <br />WITHOUT PROPER NOTIFICATION SHALL BE BORNE BY THE INDIVIDUAL <br />CONTRACTOR INVOLVED. <br />2. THE CONTRACT DOCUMENTS INDICATE THE EXTENT AND APPROXIMATE <br />LOCATION OF ELEMENTS OF THE BUILDING AND SITE. ALL CONDITIONS, <br />LOCATIONS, DEVICES AND ELEMENTS SHALL BE VERIFIED BY THE <br />CONTRACTOR PRIOR TO COMMENCING THE WORK. <br />3. ALL WORK PERFORMED IN CONNECTION WITH THESE CONTRACT DOCUMENTS <br />SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (ADA), ALL <br />APPLICABLE STATE AND LOCAL CODES, ORDINANCES, AND ZONING <br />REGULATIONS IN EFFECT AT THE TIME OF CONSTRUCTION. THIS PROJECT <br />SHALL COMPLY WITH TITLE 24, 2016 CBC, CMC, CPC, CFC, CEC BASED ON <br />THE 2016 CALIFORNIA ENERGY STANDARDS. <br />4. IT SHALL BE UNDERSTOOD THAT THE INTENT OF THESE CONSTRUCTION <br />DOCUMENTS IS TO CONSTRUCT THE FACILITY IN ACCORDANCE WITH THE <br />APPLICABLE CODES AND ORDINANCES. SHOULD ANY CONDITION BE <br />UNCOVERED OR DEVELOP DURING THE EXECUTION OF THESE DOCUMENTS, <br />WHICH IS NOT DEFINED HEREIN, THE CONTRACTOR SHALL CEASE WORK AND <br />NOTIFY THE ARCHITECT AT ONCE. <br />5. THE TYPICAL DETAILS SHOWN IN THESE PLANS SHALL APPLY IN ALL <br />SIMILAR CASES UNLESS SPECIFICALLY NOTED OTHERWISE. WHERE NO <br />DETAIL IS SHOWN, CONSTRUCTION SHALL BE AS INDICATED FOR OTHER <br />SIMILAR WORK AND, OR APPLICABLE INDUSTRY PRACTICE. <br />6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION OF <br />INSTALLATION, INSPECTION, AND FINAL APPROVAL OF ALL UTILITIES. <br />7. VERIFY ALL DIMENSIONS, EXISTING CONDITIONS, AND METHODS OF <br />CONSTRUCTION PRIOR TO START OF ANY WORK. NOTIFY THE ARCHITECT <br />OF ANY DISCREPANCIES. <br />8. IT IS NOT THE INTENT OF THESE CONTRACT DOCUMENTS TO SEPARATE THE <br />WORK INTO SUBTRADE DIVISIONS. IT SHALL BE THE RESPONSIBILITY OF <br />THE GENERAL CONTRACTOR TO DIVIDE THE WORK AND ORGANIZE ALL <br />WORK AS REQUIRED TO COMPLETE THE WORK AS INTENDED BY THESE <br />DOCUMENTS. <br />9. SITE DEVELOPMENT AND GRADING SHALL PROVIDE ACCESS TO PRIMARY <br />ENTRANCES AND NORMAL PATHS OF TRAVEL, AND SHALL INCORPORATE <br />PEDESTRIAN RAMPS, CURB RAMPS, ETC. ALL RAMPS SHALL HAVE A MAXIMUM <br />SLOPE OF 1:12, OR AS NOTED ON THESE CONSTRUCTION DOCUMENTS. ANY <br />PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF IT'S SLOPE IS <br />GREATER THAN 1 FT. RISE IN 20 FT. RUN (5%) <br />10. EACH PARKING FACILITY WHERE PARKING IS PROVIDED FOR THE PUBLIC, <br />GUESTS OR EMPLOYEES SHALL PROVIDE ACCESSIBLE PARKING AND <br />LOADING STALLS DESIGNATED SPECIFICALLY FOR PERSONS WITH <br />DISABILITIES. <br />11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION <br />OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO THE COMMENCEMENT <br /> OF WORK. HE SHALL BE RESPONSIBLE FOR THE LOCATION AND <br />PRESERVATION OF ALL SUCH FACILITIES IN THE AREA OF CONSTRUCTION, <br /> AND SHALL NOTIFY UTILITY COMPANIES 48 HOURS IN ADVANCE OF ANY <br />CONSTRUCTION (UNDERGROUND SERVICE ALERT 1-800-227-2600) <br />12. EACH ACCESSIBLE PARKING SHALL BE IDENTIFIED BY A REFLECTORIZED <br />SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE <br />FROM EACH STALL OR SPACE, CONSISTING OF A PROFILE VIEW OF A <br />WHEELCHAIR OCCUPANT IN WHITE ON A BLUE BACKGROUND. THE SIGN SHALL <br />NOT BE SMALLER THAN 70 SQ. IN. IN AREA AND, WHEN POSTED IN A PATH OF <br />TRAVEL, SHALL BE A MINIMUM HEIGHT OF 80 INCHES FROM THE BOTTOM OF <br />THE SIGN TO THE PARKING SPACE FINISH GRADE, UON. IN ADDITION, A <br />SIGN, AS SPECIFIED IN TITLE 24 ACCESSIBILITY STANDARDS, SHALL BE <br />POSTED IN A CONSPICUOUS PLACE, AT EACH ENTRANCE TO OFF-STREET <br />PARKING FACILITIES, OR IMMEDIATELY ADJACENT TO AND VISIBLE FROM <br />EACH STALL OR SPACE. SAID SIGNS SHALL BE NOT LESS THAN 17 INCHES X <br />22 INCHES IN SIZE WITH LETTERING NOT LESS THAN 1 INCH HIGH. <br />13. PROVIDE A CLEAR AND LEVEL LANDING ON EACH SIDE OF AN EXIT DOOR. <br />THE LANDING SHALL BE 48 INCHES IN LENGTH WHERE THE DOOR SWINGS <br />AWAY FROM THE LANDING, AND 60 INCHES IN LENGTH IN THE DIRECTION <br />OF DOOR SWING AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE <br />DOOR IN THE CLOSED POSITION. <br />14. GENERAL DEMOLITION: WHENEVER EXISTING FACILITIES OR MATERIALS <br />ARE REMOVED, DAMAGED, BROKEN, OR CUT IN THE INSTALLATION OF WORK <br />COVERED BY THE DRAWINGS AND SPECIFICATIONS, SAID FACILITIES AND <br />MATERIALS SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. SAID <br />FACILITIES OR MATERIALS SHALL BE EQUAL TO OR BETTER THAN THE <br />ORIGINAL FACILITIES OR MATERIALS. THE FINISH PRODUCT SHALL BE <br />SUBJECT TO THE APPROVAL OF THE COUNTY AND ITS AGENTS. <br />15. NO WORK SHALL COMMENCE AT THE PROJECT SITE BEFORE A BUILDING <br />PERMIT IS FULLY EXECUTED AND AVAILABLE FOR POSTING AT THE JOB <br />SITE. <br />16. CONSTRUCTION LIMITS: CONTRACTOR AND SUB-CONTRACTORS, WORKERS <br />AND OTHER PERSONNEL RELATED TO THIS SCOPE OF WORK, SHALL BE <br />CONFINED WITH THE AREAS DESIGNATED AS CONSTRUCTION LIMITS AS <br />INDICATED BY THESE DRAWINGS AND RELATED AREAS. AREAS BEYOND <br />THIS SCOPE OF WORK SHALL BE OFF LIMITS, AND THEIR USE SHALL BE <br />PROHIBITED WITHOUT PRIOR AUTHORIZATION OF SAN JOAQUIN COUNTY. <br />THE GENERAL CONTRACTOR SHALL VERIFY THESE LIMITS AND BE <br />RESPONSIBLE TO INFORM THE APPROPRIATE PERSONNEL AND ENFORCE <br />THESE LIMITS. <br />17. PROVIDE CONTINUOUS 16GA. X REQUIRED WIDTH (6" MIN.) FLAT BACKING <br />STRAP AT WALLS WITH WALL MOUNTED EQUIPMENT, CASEWORK, AND/OR <br />ACCESSORIES - TYPICAL UNLESS OTHERWISE NOTED. <br />18. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT <br />DOCUMENTS AND THE EXISTING FIELD CONDITIONS, AND SHALL AT ONCE <br />REPORT TO THE ARCHITECT ANY ERROR, INCONSISTENCY, OR OMISSION <br />HE MAY DISCOVER. THE CONTRACTOR SHALL PERFORM NO PORTION OF THE <br />WORK AT ANY TIME WITHOUT APPROVED CONTRACT DOCUMENTS OR WHERE <br />REQUIRED, APPROVED SHOP DRAWINGS, PRODUCT LITERATURE, DATA, <br />SAMPLES OR INSTALLATION INSTRUCTIONS. <br />19. THE CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT, WHERE <br />APPLICABLE, FOR ANY WORK DONE WITHIN THE RIGHT-OF-WAY OR <br />EASEMENTS FROM THE AUTHORITY HAVING JURISDICTION. THE <br />CONTRACTOR SHALL NOTIFY THE OWNER 48 HOURS IN ADVANCE OF <br />COMMENCEMENT OF THE WORK OR AS REQUIRED BY SAID PERMITS. <br />20 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, OR <br />PATCHING THAT MAY BE REQUIRED TO COMPLETE THE INTENT OF THESE <br />CONSTRUCTION DOCUMENTS, TO MAKE IT'S SEVERAL PARTS FIT TOGETHER <br />PROPERLY. THE CONTRACTOR SHALL PATCH ARCHITECTURAL FINISHES AS <br />NECESSARY TO ACCOMPLISH WORK DEFINED IN STRUCTURAL, MECHANICAL, <br />PLUMBING, ELECTRICAL, AND ARCHITECTURAL DRAWINGS. EXISTING FIELD <br />CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR AND ACCEPTED AS <br />CONDITIONS OF THIS SCOPE OF WORK. <br />21. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PG&E AND/OR <br />SERVICE PROVIDER FOR ANY NEW SERVICE INSTALLATIONS. THE <br />CONTRACTOR SHALL COORDINATE THE SHUT DOWN OF THE FACILITIES <br />WITH THE OWNER FOR AS MINIMAL DURATION AS POSSIBLE. INTERCEPT <br />THE EXISTING SERVICE CONDUIT, EXTEND IT TO NEW TRANSFORMERS AND <br />PAD (TO BE INSTALLED BY CONTRACTOR) AND EXTEND SECONDARY <br />CONDUITS TO THE NEW SWITCHBOARD. COORDINATE WITH THE OWNER TO <br />VERIFY LOCATION, PROVIDE TRAFFIC BARRIER POSTS PER PG&E <br />REQUIREMENTS. <br />22. CONTRACTOR SHALL FLUSH ALL WATER, SEWER, AND DRAIN LINES PRIOR <br />TO HOOK UP. <br />23. DIMENSIONS SHALL BE MEASURED TO FACE OF FRAMING, U.O.N. DO NOT <br />SCALE DRAWINGS. <br />24. PROVIDE 2% SLOPE AWAY FROM THE BUILDING FOR 10'-0" AT FRONT AND <br />SIDES. <br />25. NO DRAINAGE ACROSS OR ONTO ADJACENT PROPERTY. PROVIDE 2% SLOPE <br />AWAY FROM THE BUILDING FOR 10'-0" AT FRONT AND SIDES. <br />26. DO NOT SCALE THE DRAWINGS. <br />PROJECT <br />LOCATION <br />VICINITY MAP <br />No. Description Date By <br />San Joaquin County <br />Environmental Health Department <br />1868 E. Hazelton Ave. <br />Stockton, CA 95205 <br />(209) 468-3420 <br /> <br />APPROVED WITH CONDITIONS <br /> <br />For conditions, please see approval letter dated: <br /> <br />Approved by:_______________________Date:_______________ <br />1-6-21 <br />Jan 06, 2021 Vidal Pedraza