Laserfiche WebLink
TYPICAL <br />(e) PANEL <br />"L130" <br />(e) PANEL <br />"H130" <br />SCALE: 1/4"=1'-0" <br />NORTH <br /> POWER FLOOR PLAN <br />.\Arch\2020-09-10\OrlandosPatio_v20_wmitchellLHLVL-LDA._ASI_CMYK.Logo-2754932.jpg <br />HCSEngineering <br />50 years HTI <br />M <br />SC.DRAHCIR <br />No. E14303 <br />Exp. 6-30-21 <br />E <br />LECTR I C A LREGISTERED P R O F ESSION <br />A <br />L <br />ENGI <br />NEERE <br />OF CAL I F O R NIASTA <br />T <br />4512 Feather River Dr #F, Stockton, CA 95219 <br />209-478-8270 | www.hcs-eng.com <br />Richard C. Smith, PE richard@hcs-eng.com <br />Bhupendra Patel, PE bhupendra@hcs-eng.com <br />Elizabeth Aguilar elizabeth@hcs-eng.com <br />PROJECT # 2020.383 <br />October 2019 <br />C32705PETERNICHOLAS <br />R <br />OSADOLICEN S E D A RC <br />HI <br />T <br />ECTSTAT <br />E <br />OF C A L IF O RNIAChecked By: <br />Drawn By: <br />Project No.: <br />LDA Partners, LLP <br />Designers & Architects <br />222 Central Court <br />Stockton, CA 95204 <br />209.943.0405 <br />www.ldapartners.com <br />Client: <br />Architect: <br />Project: <br />MMS/GJT <br />RCS <br />2018.383 <br />12/21/2020 <br />NITRO BOBA TI-SUITE A130 AT <br />STONE CREEK VILLAGE, <br />STOCKTON, CA <br />ADRESS LINE 1 <br />Mr. Vy H Vy & Mrs. Jenny <br />Pham <br />xxx.xxx.xxxx <br />ADRESS LINE 2 <br />ADDRESS LINE 1 <br />ADDRESS LINE 2 <br />No.Description Date By <br />LEGEND <br />E1.0 <br />GENERAL NOTES: <br />1. ELECTRICAL INSTALLATION SHALL COMPLY WITH TITLE 24, CALIFORNIA <br />CODE OF REGULATIONS, INCLUDING THE FOLLOWING: <br />TITLE 24, CCR, PART 2, 2016 CBC <br />TITLE 24, CCR, PART 3, 2016 CEC <br />TITLE 24, CCR, PART 4, 2016 CMC <br />TITLE 24, CCR, PART 9, 2016 CFC <br />ALL APPLICABLE LOCAL CODES. <br />2. ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL LICENSES, ETC. <br />REQUIRED TO CARRY ON AND COMPLETE THE WORK. PERMIT BY OWNER. <br />3. PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, TRANSPORTATION AND <br />PERFORM ALL OPERATIONS NECESSARY FOR ANY REASONABLE INCIDENTAL TO PROPER <br />EXECUTION AND COMPLETION OF ALL "ELECTRICAL WORK" WHETHER SPECIFICALLY <br />MENTIONED OR NOT; ALL AS INDICATED, SPECIFIED HEREIN, AND/OR IMPLIED THEREBY TO <br />CARRY OUT THE APPARENT INTENT THEREOF. <br />4. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED WITH THE UNDERWRITERS' <br />LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND SHALL BEAR THEIR LABEL <br />WHEREVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY <br />FURNISHED BY THAT AGENCY. <br />5. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE SIZE <br />AND LOCATIONS OF EQUIPMENT ARE SHOWN TO SCALE WHEREVER POSSIBLE, <br />CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL CONTRACT DOCUMENTS AND VERIFY <br />THIS INFORMATION AT THE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT <br />AND INSTALLING HIS WORK TO AVOID INTERFERENCE WITH OTHER TRADES. <br />6. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THWN UNLESS OTHERWISE <br />NOTED OR REQUIRED BY CODE. <br />NAMEPLATES & IDENTIFICATION: <br />INSTALL ENGRAVED NAMEPLATES FOR EACH PANELBOARD, CABINET, DISCONNECT, ETC. <br />NAMEPLATES SHALL BE SECURELY FASTENED TO THE EQUIPMENT WITH #4 PHILLIPS <br />ROUND HEAD CADMIUM PLATED SELF-TAPPING SCREWS, BRASS BOLT, OR WITH A PLASTIC <br />RESIN ADHESIVE GLUE, GOODYEAR "PLIEBOND" OR EQUAL. <br />WIRING METHODS: <br />1. ALL WIRING SHALL BE INSTALLED IN STEEL CONDUITS, CONCEALED IN WALL AND <br />CEILING U.O.N. <br />2. MINIMUM CONDUIT SIZE SHALL BE 1/2". MINIMUM ACCEPTABLE CONDUITS ARE <br /> A. GALVANIZED RIGID STEEL. <br /> B. GALVANIZED STEEL EMT. <br /> C. LIQUID TIGHT STEEL FLEX - FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT. <br /> D. FLEXIBLE STEEL CONDUIT - FOR INDOOR FINAL CONNECTIONS TO <br /> MECHANICAL EQUIPMENT (NOT TO EXCEED 36"). <br /> E. PVC CONDUIT SCHEDULE 40, UNDERGROUND. <br />3. NMC CABLING SYSTEMS ARE NOT ALLOWED IN THIS BUILDING. <br />4. MC CABLING SYSTEMS ARE NOT ALLOWED IN THIS BUILDING. <br />WIRING DEVICES: <br />UNITS SHALL BE EQUAL TO THE DEVICES SET FORTH HEREIN, IN STANDARD COLORS <br />(BROWN, WHITE, GREY, BEIGE OR IVORY) AS SELECTED BY THE ARCHITECT: <br /> A. WIRING DEVICES LEVITON # HUBBELL # P & S # <br /> DUPLEX CONV. OUT. 15A 5262 5262 5262 <br /> DUPLEX GFI CONV. OUT. GF5262 <br />DEVICE PLATES: <br />1. ALL DEVICE PLATES FOR INDOOR USE SHALL BE SMOOTH NYLON OR APPROVED EQUAL <br />UNLESS OTHERWISE NOTED. ALL DEVICE PLATES FOR OUTDOOR USE SHALL BE RAISED <br />METAL. <br />2. DEVICE COVERS FOR SURFACE MOUNTED BOXES SHALL BE 1/2" RAISED STEEL PLATES. <br />WEATHERPROOF COVERS TO BE SNAP TYPE COVERS. <br />SUPPORTS: <br />1. FURNISH ALL NECESSARY FOUNDATIONS, SUPPORTS, BACKING, ETC., FOR ALL <br />ELECTRICAL ENCLOSURES, CONDUITS AND EQUIPMENT. <br />2. ATTACH ALL BOXES, CABINETS, ETC. TO WOOD WITH WOOD OR LAG SCREWS, TO <br />METAL WITH MACHINE SCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION ANCHORS <br />AND MACHINE SCREWS OR BOLTS. <br />GROUNDING: <br />1. GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND <br />SPECIFICALLY INCLUDING SWITCHBOARD, PANELBOARDS, MOTOR CASES, ETC. <br />PANELBOARDS: <br />UNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON THE PANEL SCHEDULE, <br />WITH THE NUMBER AND SIZE OF BREAKERS INDICATED ON THE PANEL SCHEDULE. SINGLE <br />POLE, TWO POLE AND THREE POLE BREAKERS SHALL BE BOLT-ON TYPE. THE PANEL <br />DOORS SHALL HAVE FLUSH TYPE LOCKS, ALL LOCKS SHALL BE KEYED ALIKE AND HAVE <br />TYPEWRITTEN DIRECTORIES INDICATING FIXTURES, EQUIPMENT, OR OUTLETS SERVICED BY <br />EACH BREAKER. ALL BUSSING SHALL BE COPPER. <br />WORKING CLEARANCES FOR PANELS & SWITCHBOARDS <br />1. COORDINATE WITH OTHER TRADES TO ENSURE CODE REQUIRED WORKING <br />CLEARANCES, ACCESS, ETC. FOR PANELS AND SWITCHBOARDS PER C.E.C. SECTIONS <br />110-16 AND 384-4. <br />TESTING: <br />1. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS AND <br />IMPROPER GROUNDS. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND <br />GROUNDS BEFORE ANY FIXTURES OR EQUIPMENT ARE CONNECTED AND WHETHER SUCH <br />TESTS INDICATE FAULTY INSULATION OR OTHER DEFECTS, THEY SHALL BE LOCATED, <br />REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE. <br />ELECTRICAL SPECIFICATIONS