Laserfiche WebLink
EXISTING WALL TO REMAIN <br />EXISTING WALL TO BE <br />DEMOLISHED <br />LEGEND <br />SAW CUT EXISTING CONC. <br />SLAB FOR INSTALLATION <br />OF PLUMBING LINES <br />EXISTING DOOR TO REMAIN <br />EXISTING STOREFRONT TO <br />REMAIN <br />1. CONTRACTOR SHALL NOT CUT OR ALTER <br />STRUCTURAL MEMBERS UNLESS INDICATED TO <br />DO SO IN THE CONTRACT DOCUMENTS OR <br />WRITTEN APPROVAL RECEIVED FROM THE <br />ARCHITECT. <br />2.UNLESS OTHERWISE NOTED ON DRAWINGS, <br />ALL MATERIAL INDICATED TO BE REMOVED <br />SHALL BECOME THE RESPONSIBILITY OF THE <br />CONTRACTOR AND SHALL BE DISPOSED <br />OUTSIDE THE PROJECT SITE. <br />3.CONTRACTOR TO CUT, CAP, AND REMOVE <br />EXISTING UTILITIES AS SHOWN. IF UTILITIES <br />OTHER THAN THOSE SHOWN ARE ENCOUNTERED, <br />IMMEDIATELY NOTIFY THE ARCHITECT, CEASE <br />OPERATION IN THE IMMEDIATE AREA AND DO <br />NOT DISTURB UNTIL THE ARCHITECT DIRECTS <br />THE DISPOSITION OF SUCH UTILITY. <br />4.DEMOLITION SHOWN IS DIAGRAMMATIC AND <br />GENERAL. PERFORM ALL DEMOLITION SHOWN <br />AND REQUIRED FOR THECONSTRUCTION OF <br />THE PROJECT INCLUDING ALL ITEMS IN THE <br />WAY OF NEW WORK WHETHER OR NOT <br />SPECIFICALLY SHOWN. <br />5.REFER TO MECHANICAL DRAWINGS FOR <br />DEMOLITION RELATIVE TO HVAC SCOPE OF <br />WORK. <br />6.REFER TO ELECTRICAL DRAWINGS FOR <br />DEMOLITION RELATIVE TO ELECTRICAL <br />SCOPE OF WORK. <br />7.PATCH AND REPAIR ALL EXISTING WALLS <br />AND FINISHES TO REMAIN. <br />VERIFY <br />3'-3"VERIFY5'-0"2'-10" <br />VERIFY <br />6'-8"9"2.5 <br />2.1 <br />2.3 <br />2.4 <br />2.6 <br />2.12 <br />2.10 <br />2.13 <br />2.14 <br />2.15 <br />2.10 <br />2.9 <br />2.232.2 <br />2.7 <br />2.8 <br />2.21 <br />2.23 <br />2.18 <br />2.19 <br />2.11 <br />2.24 <br />2.22 <br />2.27 <br />2.162.16 <br />2.17 <br />2.25 <br />2.20 <br />2.26 <br />2.30 <br />2.31 <br />2.32 <br />2.14 <br />2.36 <br />July 20____ <br />C33148CAROLYNMOEA N <br />A <br />T <br />I <br />VI <br />DADLICEN S E D A RC <br />HI <br />T <br />ECTSTAT <br />E <br />OF C A L IF O RNIAChecked By: <br />Drawn By: <br />Project No.: <br />LDA Partners, Inc <br />Designers & Architects <br />222 Central Court <br />Stockton, CA 95204 <br />209.943.0405 <br />www.ldapartners.com <br />Client: <br />Architect: <br />Project: <br />NOR FOR CONSTRUCTION <br />12/23/2020 4:31:09 PMDEMOLITION FLOOR PLAN <br />A2.00 <br />BC, BB <br />CN <br />###-#-## <br />PLAN CHECK 1 <br />12/24/2020 <br />NITRO BOBA TI <br />5757 PACIFIC AVE. <br />Mr. Vy H Vy & Mrs. Jenny <br />Pham <br />###.###.#### <br />STOCKTON, CA <br />SUITE A130, STONE <br />CREEK VILLAGE <br />STOCKTON, CA <br />GENERAL NOTES <br />KEYNOTES <br />2.1 EXISTING ELECTRICAL CABINET TO <br />REMAIN <br />2.2 EXISTING DOOR TO REMAIN, TYP. <br />2.3 EXISTING FAUCET AND MOP SINK TO <br />REMAIN <br />2.4 EXISTING LAVATORY AND FAUCET TO <br />REMAIN <br />2.5 EXISTING ELECTRICAL CONDUITS TO BE <br />RELOCATED, S.E.D. <br />2.6 EXISTING WALL MOUNTED SOAP <br />DISPENSER TO REMAIN <br />2.7 EXISTING MIRROR TO REMAIN <br />2.8 SAW-CUT & PATCH EXISTING CONCRETE TO <br />EXTEND CONDUIT LINES, S.E.D. <br />2.9 EXISTING STEEL COLUMN TO REMAIN - <br />TYP. <br />2.10 EXISTING GRAB BAR TO REMAIN <br />2.11 EXISTING THERMOSTAT TO BE <br />RELOCATED, S.E.D. <br />2.12 EXISTING TOILET SEAT COVER <br />DISPENSER TO BE RELOCATED <br />2.13 EXISTING WALL MOUNTED PAPER TOWEL <br />DISPENSER TO REMAIN <br />2.14 EXISTING FLOOR DRAIN TO REMAIN <br />2.15 EXISTING FLOOR MOUNTED TOILET TO <br />REMAIN <br />2.16 EXISTING STAINED CONCRETE FLOOR TO <br />REMAIN, TYP. <br />2.17 FRAME NEW DOOR OPENING AT EXISTING <br />WALL AND INFILL, SEE PLAN FOR <br />LOCATION <br />2.18 EXISTING FLOOR SINK TO REMAIN <br />2.19 DEMOLISH (E) WALL TO ACCEPT 3'0" WIDE <br />7'-0" TALL FRAMED OPENING <br />2.20 EXISTING STOREFRONT WINDOW SYSTEMS <br />TO REMAIN - TYP. <br />2.21 EXISTING HOT WATER HEATER TO <br />RELOCATE, S.P.D. <br />2.22 EXISTING 3-COMPARTMENTS SINK AND <br />FAUCET TO REMAIN <br />2.23 EXISTING TOILET PAPER DISPENSER TO <br />REMAIN <br />2.24 EXISTING FIRE EXSTINGUSHER TO BE <br />RELOCATED <br />2.25 EXISTING OPENING TO INFILL <br />2.26 EXISTING HSS COLUMN TO REMAIN, TYP. <br />2.27 EXISTING HAND-WASH SINK TO RELOCATE <br />2.30 DEMOLISH WALL TO ACCEPT NEW <br />PLUMBING LINES, S.P.D. <br />2.31 EXISTING WALL MOUNTED SOAP <br />DISPENSER TO RELOCATE <br />2.32 EXISTING WALL MOUNTED PAPER TOWEL <br />DISPENSER TO RELOCATE <br />2.36 SAW-CUT & PATCH EXISTING CONCRETE <br />FOR UNDERGOUND PLUMBING, S.P.D. <br />1/4" = 1'-0"A2.00 <br />2 DEMOLITION FLOOR PLAN <br />No. Description Date By