Laserfiche WebLink
CALIFORNIA BUILDING CODE NOTESDOOR SCHEDULETYPESIZE HDWR GROUPALUMINUM STOREFRONT3'-0" X 6'-8"1DOOR NOTES:1. ALL DOOR AND DOOR FUNCTIONS SHALL MEET CBC CHAPTER 11B ACCESSIBLITY AND CHAPTER 10 EXITING REQUIREMENTS. 2. PLEASE SEE FLOOR PLAN NOTES FOR MORE INFORMATION. 3. DOORS LABELED (R) ARE EXISTING UNITS TO BE REPLACED WITH NEW LARGER DOORS AND/OR TO HAVE NEW HARDWARE INSTALLED TO MEET ACCESSIBILITY & EGRESS CODE PROVISIONS.CBC - ACCESSIBILITY NOTES1. PROVIDE ALUMINUM THRESHOLDS AT ALL SOLID CORE EXTERIOR DOORS. 2. WHEN INSTALLED, DOORS SHALL BE CAPABLE OF OPENING SO THAT THE CLEAR WIDTH IS NOT LESS THAN 32 INCHES, MEASURED BETWEEN THE OPPOSITE FACE OF THE DOOR AND THE OPPOSITE STOP. FOR HINGED DOORS, THE OPENING WIDTH SHALL BE MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM IT'S CLOSED POSITION. ALL EXTERIOR GROUND FLOOR EXIT DOORS TO BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO PERSONS WITH DISABILITIES. 3. EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL AND BE EQUIPPED WITH PANIC HARDWARE OR ABLE TO OPEN AUTOMATICALLY. EXIT DOORS SHALL HAVE LISTED EXIT HARDWARE AND ARE TO BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. REQUIRED EXIT DOORS SHALL NOT BE LESS THAN 36 INCHES IN WIDTH AND NOT LESS THAN 80 INCHES IN HEIGHT. PROVIDE A SIGN ON OR NEAR A MAIN EXIT DOOR READING, "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED", WITH 1" HIGH LETTERS ON A CONTRASTING BACKGROUND.4. ALL DOORS THAT PROVIDE ACCESS TO THE MAIN BLDG. EXIT THROUGH INTERVENING ROOMS SHALL NOT HAVE THE ABILITY TO BE LOCKED TRAPPING AN OCCUPANT WITHIN THE ROOM.5. LATCHING AND LOCKING DOORS THAT ARE HAND OPERATED SHALL BE OPERABLE WITH A SINGLE EFFORT WITHOUT REQUIRING THE ABILITY TO GRASP THE HARDWARE (LEVER OR PUSH TYPE).6. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED THE FOLLOWING REQUIREMENTS:A. INTERIOR DOORS - 5 POUNDSB. EXTERIOR DOORS - 5 POUNDSC. FIRE DOORS - 15 POUNDS7. OPENING HARDWARE IS TO BE CENTERED BETWEEN 34 INCHES MIN. AND 44 INCHES MAX. ABOVE FINISH FLOOR. THE LEVER OF LEVER ACTUATED LATCHES OR LOCKS SHALL BE CURVED WITH A RETURN TO WITHIN 1/2" OF THE DOOR TO PREVENT CATCHING ON CLOTHING OF PERSONS DURING EGRESS.8. THE BOTTOM 10 INCHES OF ALL DOORS, EXCEPT AUTOMATIC AND SLIDING DOORS, SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10 INCH HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.9. THE FLOOR AND LANDING SHALL BE NOT MORE THAN 1/2 INCH LOWER THAN THE TOP OF THE THRESHOLD OF THE DOORWAY. BEVEL (1:2 MAX. SLOPE) WHERE THE THRESHOLD EXCEEDS 1/4 INCH IN HEIGHT. CHANGES IN LEVEL UP TO 1/4 INCH MAY BE VERTICAL AND WITHOUT EDGE TREATMENT.10. ALL GLAZING WITHIN A 24 INCH ARC OF EITHER EDGE OF A DOOR AND WITHIN 60 INCHES OF THE FLOOR SHALL BE TEMPERED.11. EXTERIOR LEVEL LANDING MAY SLOPE UP TO 1/4 INCH PER FOOT IN ANY DIRECTION FOR SURFACE DRAINAGE.12. ALL FINISHES ARE TO BE APPLIED IN STRICT ACCORDANCE TO MANUFACTURER'S SPECIFICATIONS.13. ALL PAINT SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'SSPECIFICATION FOR THE PARTICULAR SURFACE.14. ALL CARPETING SHALL BE INSTALLED WITH GLUE DOWN METHOD, UON., AND SECURELY ATTACHED. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO THE FLOOR SURFACES AND HAVE TRIM ALONG THE ENTIRE EDGE, AND THE EDGE SHALL COMPLY WITH CBC SECTION 11B-302.2.15. ALL RECEPTACLES AND SWITCHES TO BE LOCATED 15" MINIMUM AND 48" MAXIMUM ABOVE FINISH FLOOR SURFACE. THE HIGH REACH IS TO THE TOP OF THE OUTLET BOX AND THE LOW REACH TO THE BOTTOM OF THE OUTLET BOX FOR BOTH RECEPTACLES AND SWITCHES.16. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90-DEGREES, TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12-DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM.CALGREEN CODE NOTESMANDATORY MEASURE (CALGREEN CHAPTER 5)1. INDOOR WATER USE - (CALGREEN SECTION 5.303) ALL NEW PLUMBING FIXTURES, OR FIXTURES PART OF AN ADDITION OR ALTERATION SHALL COMPLY WITH THE FOLLOWING MANDATORY ALLOWABLE FLOW RATES.2. CONSTRUCTION WASTE REDUCTION, DISPOSAL, & RECYCLING (CALGREEN SECTION 5.408)A. 5.408.1 CONSTRUCTION WASTE MANAGEMENT. RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 50% OF THE NONHAZARDOUS CONSTRUCTION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2 OR 5.408.1.3 OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS MORE STRINGENT. 5.408.1.1 CONSTRUCTION WASTE MANAGEMENT PLAN. WHERE A LOCAL JURISDICTION DOES NOT HAVE A CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE THAT IS MORE STRINGENT, SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN THAT COMPLIES WITH ITEMS 1 THROUGH 4 OF THIS SECTION. B. 5.408.1.2 WASTE MANAGEMENT COMPANY. UTILIZE A WASTE MANAGEMENT COMPANY THAT CAN PROVIDE VERIFIABLE DOCUMENTATION THAT THE PERCENTAGE OF CONSTRUCTION WASTE MATERIAL DIVERTED FROM THE LANDFILL COMPLIES WITH THIS SECTION. EXCEPTIONS TO SECTIONS 5.408.1.1 AND 5.408.1.2: 1. EXCAVATED SOIL AND LAND-CLEARING DEBRIS 2. ALTERNATE WASTE REDUCTION METHODS DEVELOPED BY WORKING WITH LOCAL AGENCIES IF DIVERSION OR RECYCLE FACILITIES CAPABLE OF COMPLIANCE WITH THIS ITEM DO NOT EXIST. 3. DEMOLITION WASTE MEETING LOCAL ORDINANCE OR CALCULATED IN CONSIDERATION OF LOCAL RECYCLING FACILITIES AND MARKETS C. 5.408.1.4 DOCUMENTATION. PROVIDE DOCUMENTATION OF THE WASTE MANAGEMENT PLAN THAT MEETS THE REQUIREMENTS LISTED IN SECTIONS 5.408.1.1 THROUGH 5.408.1.3, AND THE PLAN IS ACCESSIBLE TO THE ENFORCEMENT AUTHORITY.EXTERIOR COMPONENTS2. WEATHERPROOF THE EXTERIOR IN COMPLIANCE WITH CBC SECTION 1403.23. ASPHALT SHINGLE ROOFING SHALL COMPLY W/CBC SECTION 1507.2. PROVIDE A TYPE I, 15# MIN, FELT UNDERLAYMENT FOR COMPOSITION ROOF COVERING PER CBC SECTION 1507.2.3. 4. VALLEYS SHALL CONSIST OF EITHER 24" WIDE CORROSION RESISTANT METAL LININGS OR AT LEAST ON PLY OF 36" WIDE SMOOTH ROLL ROOFING OR SELF-ADHERING MODIFIED BITUMEN UNDERLAYMENT (@ CLOSED VALLEYS). ROLLED COMPOSITION ROOFING SHALL COMPLY WITH CBC SECTION 1507.10.5. PROVIDE PRESERVATIVE TREATED OR NATURALLY DURABLE WOOD WHERE FRAMING IS IN CONTACT WITH CONCRETE OR LACKS CLEARANCE IN COMPLIANCE WITH CBC SECTION 2304.12.6. EXTERIOR STUCCO WALL SHALL HAVE A WEEP SCREED AT OR BELOW THE FOUNDATION PLATE LINE AND 4" ABOVE GRADE OR 2" ABOVE PAVED AREAS THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. (CBC 2512.1.2)FIRE PROTECTION REQUIREMENTS7. WALLS, CEILINGS, AND SOFFITS UNDER STAIRWAYS SHALL BE ENCLOSED AS REQUIRED FOR ONE HOUR FIRE-RESISTIVE CONSTRUCTION. (CBC SECTION 1023.2.)8. FIRE BLOCK AT WALLS AT STAIR STRINGERS, DROP CEILINGS, COVE CEILINGS, FLOORS, SHOWERS, SOFFITS, AND AT OPENINGS AROUND DUCTS, VENTS, PIPES, AND FLUE CHASES. FIRE BLOCKING SHALL BE PROVIDED VERTICALLY AT THE CEILING AND FLOOR LEVELS AND HORIZONTALLY AT INTERVALS NOT TO EXCEED 10'-0" MAXIMUM. (CBC SECTION 718.2)9. WALL AND CEILING FINISHES IN ROOMS AND ENCLOSED SPACES SHALL COMPLY WITH CLASS C FLAME SPREAD AND SMOKE-DEVELOPED INDEXES. WALL AND CEILING FINISHES IN INTERIOR EXIT STAIRWAYS, RAMPS, AND PASSAGEWAYS SHALL COMPLY WITH CLASS B FLAME SPREAD AND SMOKE-DEVELOPED INDEXES. ALL WALL AND CEILING FINISHES IN A SPRINKLERED UNIT SHALL COMPLY WITH CLASS C FLAME SPREAD AND SMOKE-DEVELOPED INDEXES. (CBC SECTION 803.1.1)10. PROVIDE FIRE BLOCKING AT ALL SPACES BETWEEN CHIMNEYS AND FLOORS AND CEILINGS THROUGH WHICH CHIMNEYS PASS. FIRE BLOCKING SHALL BE SELF SUPPORTING OR BE PLACED ON STRIPS OF METAL OR METAL LATH LAID AREAS ACROSS SPACES BETWEEN COMBUSTIBLE MATERIAL AND THE CHIMNEY (CBC SECTION 718.2.5.)11. A 1 3/8" THICK SOLID CORE WOOD OR HONEYCOMB CORE STEEL DOOR IS REQUIRED AT ALL DOORS LEADING FROM THE RESIDENCE TO THE GARAGE AND SHALL BE SELF-CLOSING AND SELF-LATCHING. EXCEPTION: A FIRE DOOR IS NOT REQUIRED WHEN THE RESIDENCE AND PRIVATE GARAGE IS PROTECTED BY A RESIDENTIAL FIRE SPRINKLER SYSTEM, THE DOOR OPENINGS NEED ONLY BE SELF-CLOSING AND SELF-LATCHING. (CBC SECTION 406.3.2.1)12. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE SPACE ABOVE BY A SINGLE LAYER OF 5/8" TYPE X GYPSUM BOARD PER CBC SECTION 406.3.4. DUCTS PENETRATING THESES WALLS OR CEILINGS SHALL BE A MINIMUM OF 26 GAGE SHEET METAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. (CBC SECTION 406.3.2.1)13. INSTALL COMBINATION SMOKE DETECTOR/CARBON MONOXIDE ALARMS IN DWELLING UNITS AND SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. ALARMS SHALL BE INTERCONNECTED SUCH THAT ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS WITHIN THE UNIT. (CBC SECTION 907.2.10.)WINDOWS14. ALL NEW OR REPLACED WINDOWS SHALL BE DUAL GLAZED WITH LOW-E GLASS. DO NOT REMOVE NFRC STICKERS FROM GLAZING PRIOR TO APPROVED INSPECTION. BEDROOM WINDOWS SHALL HAVE A MINIMUM NET CLEAR ESCAPE OPENING OF 5.7 SF WITH A MINIMUM NET CLEAR OPENING HEIGHT OF 24" AND MINIMUM NET CLEAR OPENING WIDTH OF 20". THE WINDOW OPENING BOTTOM EDGE SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR. (CBC SECTION 1030)15. THE CONTRACTOR SHALL PROVIDE SAFETY GLAZING FOR ALL CONDITIONS DEEMED A "HAZARDOUS LOCATION" PER CBC SECTION 2406.4.STAIRWAYS16. PROVIDE GUARDS OR HANDRAILS THAT ARE TESTED TO RESIST A CONCENTRATED HORIZONTAL FORCE OF 200 LBS APPLIED AT THE TOP OF THE BARRIER IN ANY DIRECTION. GUARDS AT OPEN-SIDING WALKING SURFACES SHALL NOT BE LESS THAN 42" HIGH, MEASURED VERTICALLY ABOVE THE LEAD EDGE OF THE STAIR TREAD NOSING. GUARDS SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. GUARDS ON THE OPEN SIDES OF STAIRS OR ACTING AS A HANDRAIL SHALL HAVE A MINIMUM HEIGHT OF 34", NO GREATER THAN 38", MEASURED VERTICALLY FROM THE LEADING EDGE OF THE TREAD NOSING, AND SHALL BE SPACED SUCH THAT A 4 3/8" SPHERE CANNOT PASS THROUGH. TREAD NOSING SHALL NOT PROJECT MORE THAN 1 1/4" BEYOND THE TREAD BELOW. STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE. (CBC SECTIONS 1014)17. STAIRWAY SHALL HAVE RISERS WITH A MAXIMUM HEIGHT OF 7 3/4" AND A MINIMUM TREAD DEPTH OF 10". A VARIATION OF NOT MORE THAN 3/8" BETWEEN THE LARGEST AND SMALLEST RISER HEIGHTS OR THE LONGEST AND SMALLEST TREAD DEPTH SHALL BE PERMITTED. (CBC SECTION 1011.5.2)BATHROOMS18. WALL FINISHES AT SHOWER/BATHTUB ENCLOSURES SHALL CONSIST OF A NON-ABSORBANT SURFACE AND EXTEND UP TO SIX FEET ABOVE FINISH FLOOR PER CBC SECTION 1209.2.3. "GREEN BOARD" IS NOT ACCEPTABLE IN SHOWER/BATHTUB ENCLOSURES. ACCEPTABLE TILE BASE MATERIALS AT SHOWER/BATHRUB ENCLOSURES INCLUDE FIBER CEMENT, FIBER MAT REINFORCED CONCRETE, GLASS MAT GYPSUM BACKERS, OR FIBER REINFORCED GYPSUM BACKERS.19. BATHROOMS, WATER CLOSET COMPARTMENTS, AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LESS THAN 3 SF, ONE-HALF OF WHICH SHALL BE OPERABLE. EXCEPTION: GLAZED AREAS ARE NOT REQUIRED WHERE ARTIFICIAL LIGHT AND A LOCAL EXHAUST SYSTEM IS PROVIDED. THE MINIMUM LOCAL EXHAUST RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. (CBC SECTION 1209.2 & CMC SECTION 605.2)20. BATHROOMS CONTAINING A BATHTUB, SHOWER, OR TUB/SHOWER COMBINATION SHALL BE MECHANICALLY VENTILATED. (CBC SECTION 1202.5.2.1) SEE CALIFORNIA MECHANICAL CODE NOTES & CALGREEN CODE NOTES FOR ADDITIONAL REQUIREMENTS.FIXTURE TYPEMANDATORY FLOW RATEFOR NEW "WATERCONSERVING" FIXTURESLAVATORY FAUCETS 0.5 GPM @ 60 PSIGRAVITY TANK TYPE WATERCLOSETS1.28 GAL/FLUSH3. BUILDING MAINTENANCE AND OPERATION (CALGREEN SECTION 5.410)A. 5.410.1 RECYCLING BY OCCUPANTS. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE DEPOSITING, STORAGE, AND COLLECTION OF NON-HAZARDOUS MATERIALS FOR RECYCLING.B. 5.410.4 TESTING AND ADJUSTING. TESTING AND ADJUSTING OF SYSTEMS SHALL BE REQUIRED FOR BUILDINGS LESS THAN 10,000 SQUARE FEET.C. 5.410.4.2 SYSTEMS. DEVELOP A WRITTEN PLAN OF PROCEDURES FOR TESTING AND ADJUSTING SYSTEMS. SYSTEMS TO BE INCLUDED FOR TESTING AND ADJUSTING SHALL INCLUDE, AS APPLICABLE TO THE PROJECT, THE SYSTEMS LISTED IN 5.410.4.2.D. 5.410.4.3 PROCEDURES. PERFORM TESTING AND ADJUSTING PROCEDURES IN ACCORDANCE WITH APPLICABLE STANDARDS ON EACH SYSTEM AS DETERMINED BY ENFORCING AGENCY. E. 5.410.4.3.1 HVAC BALANCING. BEFORE A NEW SPACE CONDITIONING SYSTEM SERVING A BUILDING OR SPACE IS OPERATED FOR NORMAL USE, THE SYSTEM SHOULD BE BALANCED IN ACCORDANCE WITH THE PROCEDURES DEFINED BY NATIONAL STANDARDS LISTED IN 5.410.3.3.1.F. 5.410.4.4 REPORTING. AFTER COMPLETION OF TESTING, ADJUSTING AND BALANCING, PROVIDE A FINAL REPORT OF TESTING SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES.G. 5.410.4.5 OPERATION AND MAINTENANCE MANUAL. PROVIDE THE BUILDING OWNER WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF GUARANTEES / WARRANTIES FOR EACH SYSTEM PRIOR TO FINAL INSPECTION.H. 5.410.4.5.1 INSPECTIONS AND REPORTS. INCLUDE A COPY OF ALL INSPECTION VERIFICATIONS AND REPORTS REQUIRED BY THE ENFORCING AGENCY.4. POLLUTANT CONTROL (CALGREEN SECTION 5.504)A. 5.504.4 FINISH MATERIAL POLLUTANT CONTROL. FINISH MATERIALS SHALL COMPLY WITH SECTIONS 5.504.4.1 THROUGH 5.504.4.4.B. 5.504.4.1 ADHESIVES, SEALANTS, CAULKS. ADHESIVES AND SEALANTS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS. a. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS, AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 5.504.4.1 AND 5.504.4.2. b. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507.C. 5.504.4.3 PAINTS AND COATINGS. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE 5.504.4.2 UNLESS MORE STRINGENT LOCAL LIMITS APPLY.D. 5.504.4.3.1 AEROSOL PAINTS AND COATINGS. AEROSOL PAINTS AND COATINGS SHALL MEET THE PRODUCT-WEIGHTED MIR LIMITS FOR ROC IN SECTION 94522(A)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES (CCR, TITLE 17, SECTION 94520 ET SEQ).E. 5.504.4.3.2 VERIFICATION. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE REQUEST OF THE ENFORCING AGENCY. F. 5.504.4.4 CARPET SYSTEMS. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF ONE OF THE STANDARDS LISTED IN 5.504.4.4.G. 5.504.4.4.1 CARPET CUSHION. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. H. 5.504.4.4.2 CARPET ADHESIVE. ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 804.4.1. I. 5.504.4.5 COMPOSITE WOOD PRODUCTS. HARDWOOD PLYWOOD, PARTICLEBOARD, AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN TABLE 5.504.4.5. J. 5.504.4.5.3 DOCUMENTATION. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL INCLUDE AT LEAST ONE OF THE FOLLOWING. 1. PRODUCT CERTIFICATIONS AND SPECIFICATIONS. 2. CHAIN OF CUSTODY CERTIFICATIONS. 3. PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE WOOD PRODUCTS REGULATION (SEE CCR, TITLE 17, SECTION 93120, ET SEQ.) 4. EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS-1 OR PS-2 STANDARDS OF THE ENGINEERED WOOD ASSOCIATION, THE AUSTRALIAN AS/NZS 2269 OR EUROPEAN 636 3S STANDARDS. 5. OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY. K. 5.504.4.6 RESILIENT FLOORING SYSTEMS. COMPLY WITH THE VOC-EMISSION LIMITS DEFINED IN THE 2009 CHPS CRITERIA AND LISTED ON ITS HIGH PERFORMANCE PRODUCTS DATABASE PRODUCTS COMPLIANT WITH CHPS CRITERIA CERTIFIED UNDER THE GREENGUARD CHILDREN & SCHOOLS PROGRAM; CERTIFIED UNDER THE FLOORSCORE PROGRAM OF THE RESILIENT FLOOR COVERING INSTITUTE; OR MEET CALIFORNIA DEPARTMENT OF PUBLIC HEALTH 2010 SPECIFICATION 01350. NO.1REMARKSPRIMARY EXITDOOR HARDWARE GROUPS:1. GROUP # 1 STOREFRONT SYSTEM EXIT DOORSHARDWARE BY DOOR MANUFACTURER SHALL INCLUDE MIN. OF PUSH AND PULL UNITS, CYLINDER, FACE MOUNTED DOOR CLOSER, OFFSET PIVOTS, NON-REMOVABLE BUTT HINGES, PANIC HARDWARE, EXIT LOCKSET, DOOR STOP, DOOR BOTTOM SWEEP, THRESHOLD, 1" RAIN DRIP, AND WEATHER STRIPPING. PROVIDE ISA DECAL ON DOOR EXTERIOR PER ACCESSIBILITY DETAILS. PROVIDE CEILING MOUNTED ILLUMINATED EXIT SIGN WITH BATTERY BACK UP & DIRECTIONAL ARROWS AS REQUIRED. PROVIDE TACTILE EXIT SIGN PER ACCESSIBILITY DETAILS. PROVIDE DECAL ABOVE DOOR INTERIOR WITH 1" HIGH LETTERS CONTRASTING WITH BACKGROUND READING "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". 2. GROUP # 2 SOLID CORE METAL EXIT DOORSHARDWARE BY DOOR MANUFACTURER SHALL INCLUDE MIN. OF PUSH AND PULL UNITS, CYLINDER, FACE MOUNTED DOOR CLOSER, OFFSET PIVOTS, NON-REMOVABLE BUTT HINGES, PANIC HARDWARE, EXIT LOCKSET, DOOR STOP, DOOR BOTTOM SWEEP, THRESHOLD, 1" RAIN DRIP, AND WEATHER STRIPPING. PROVIDE ISA DECAL ON DOOR EXTERIOR PER ACCESSIBILITY DETAILS. PROVIDE CEILING MOUNTED ILLUMINATED EXIT SIGN WITH BATTERY BACK UP & DIRECTIONAL ARROWS AS REQUIRED. PROVIDE TACTILE EXIT SIGN PER ACCESSIBILITY DETAILS. PROVIDE DECAL ABOVE DOOR INTERIOR WITH 1" HIGH LETTERS CONTRASTING WITH BACKGROUND READING "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". 6. GROUP # 3 RESTROOM PRIVACY, STORAGE & OFFICE PASSAGEBUTT HINGES, PRIVACY AND/OR PASSAGE LOCKSET AS REQUIRED, DOOR STOP, CLOSER, AND SWEEP. INCLUDE SIGNAGE PER CBC CHAPTER 11B AND ACCESSIBILITY DETAILS WHERE REQUIRED.REPAIRS / ALTERNATIONS / ADDITIONS:1. BUILDING CODE REQUIREMENTS ARE APPLICABLE WHERE COMPONENTS ARE WITHIN SCOPE OF REPAIR, ALTERATION, OR ADDITION.SOLID CORE METAL 3'-0" X 6'-8"22PRIMARY EXITPRIVACY 2'-6" X 6'-8"33PASSAGESOLID CORE METAL 3'-0" X 6'-8"4DEGENKOLB ENGINEERS428 J ST, SUITE 500SACRAMENTO, CA 95814916.418.9100 (P)www.degenkolb.comSAN FRANCISCO LOS ANGELES OAKLAND SACRAMENTO SAN DIEGO SEATTLE TAHOEPETERILDASN NJ.No. 4901CUSCFOETREGRISREATSTEDTATAIEN G IN EERARL ROFIUNLExp. 6-30-21CTUURALRTS DATESheet ProjecDRAWNJOB NOSHEETREVISIONS:PojectSheet TitleFile Path:C:\Users\kworcester\Documents\C1A84192.00-El Forastero_R20_kworcester.rvt06/25/19GGC1A84192.00A0.3STANDARD NOTESEL FORASTERO MEXICAN FOOD1718 E. HAMMER LNSTOCKTON, CA 95210DateDescription01/21/2022