My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2022 11:51:23 AM
Creation date
3/23/2022 2:57:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized fist of underground storage tank violations that have not <br />been addressed for United # 5446 as of August 01, 2022. <br />Open violations from March 29, 2022 inspection <br />Violation #115 - Failure to submit "Monitoring System Certification Form" within 30 days of completion of <br />the test. <br />OBSERVATION A partial monitoring system certification was performed on 12/2/2021 for service request <br />SR0083729. A test report has not been submitted to the EHD or the California Environmental Reporting System <br />(CERS). <br />REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the test. <br />CORRECTIVE ACTION: Immediately provide this report to the EHD. <br />❑ This violation was corrected ❑ This violation will be corrected by (date): <br />❑ Supporting documents included <br />Describe actions taken or will be taken to correct violation: <br />Violation #202 - Failure to retain a paper or electronic copy of the permit to operate at the facility. <br />OBSERVATION A current copy of the UST operating permit was not found on site. The most recent permit on site <br />was dated 2021. <br />REGULATION GUIDANCE: A copy of the UST operating permit and all attachments and conditions shall be <br />retained at the facility. <br />CORRECTIVE ACTION: Immediately obtain a copy of the 2022 permit and retain it on site. <br />❑ This violation was corrected ❑ This violation will be corrected by (date): <br />❑ Supporting documents included <br />Describe actions taken or will be taken to correct violation: <br />Violation #208 - Failure to comply with the designated operator inspection requirements. <br />OBSERVATION The designated operator (DO) failed to check and note all required items on the visual inspection <br />reports. The incorrect and missing information included the following from the inspection reports: <br />-The 3/21/2022 DO report did not have the box'Mechanical Float Mechanisms used in UDC's" checked off <br />-The 11/22/2021 DO report says that it was provided to the owner on 11/22/2021 but the UST Owner/Operator <br />signed the report on 11/21/2021 <br />REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required <br />testing and maintenance for the UST system have been completed and shall check all required items on the report. <br />CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br />all of the required information on the reports. <br />Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.