My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NORTHBANK
>
504
>
3600 - Recreational Health Program
>
PR0360522
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2022 8:56:10 AM
Creation date
3/31/2022 12:39:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0360522
PE
3612
FACILITY_ID
FA0002771
FACILITY_NAME
RIVER ROCK APARTMENTS
STREET_NUMBER
504
STREET_NAME
NORTHBANK
STREET_TYPE
CT
City
STOCKTON
Zip
95207
APN
10238051
CURRENT_STATUS
01
SITE_LOCATION
504 NORTHBANK CT
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN-JOAQUIN Environmental Health Department <br /> COUNTY <br /> —"` •- Time In: 930 am <br /> •'C1FaR�;` Greotness grows here. <br /> Time Out: 10:05 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: RIVER ROCK APARTMENTS Date: 07/25/2022 <br /> Address: 504 NORTHBANK CT, STOCKTON 95207 <br /> Owner/Operator: PACIFIC COMMONS APTS JOINT VEN Telephone: (209)477-6037 <br /> Program Element: 3612-PUBLIC POOL/SPA-ADDITIONAL <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #10 Disinfectant Residual MAJOR <br /> OBSERVATIONS:Free chlorine is 0 ppm.Adjust to 2 ppm to 10 ppm. Close pool until the corrections are made and verified <br /> by this department. <br /> CALCODE DESCRIPTION:Public pools, when open or in use,shall be disinfected continuously by approved chemicals and shall maintain <br /> the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br /> or 2.0 ppm bromine. Spas, wading pools,and spray grounds shall maintain the following concentrations:3.0 ppm to 10.0 ppm free <br /> chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #4 Safety Equipment <br /> OBSERVATIONS:The life ring was observed without a throw rope. Provide a throw rope for the life ring today. <br /> CALCODE DESCRIPTION:Safety equipment shall be provided, maintained, readily visible, and available for use.Pools shall have at <br /> minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br /> rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br /> (CCR 65540) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Pool light is not functioning. Repair/replace within two weeks. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31156) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The shallow end handrail was observed loose. Repair/replace handrail within five days. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> FA0002771 PR0360522 SCO01 07/25/2022 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.