Laserfiche WebLink
[� ❑ 4.2 Description/discussion of any existing and/or potential groundwater contaimination issues in the general location <br /> of the site. <br /> ❑ E� 4.3 Description of location (address/APN), type and construction of well and location (well head/kitchen tap)where <br /> water,sample(s)were obtained. <br /> 4V We�(-- No T <br /> ❑ E7 4.4 Description of constituents being tested for in the water sample. <br /> ❑ [� 4.5 Description of how sample was obtained, handled, stored, and transported to the lab. <br /> ❑ E/ 4.6 Complete Chain of Custody document, including printed and signed name of third party sampler,condition of <br /> sample and date and time the sample was submitted to the lab. For Laboratory samplers, complete laboratory <br /> report to include the above noted information. <br /> 5.0 SOIL PROFILE INFORMATION SECTION <br /> ❑ 5.1 Site map showing the location,with dimensions, of the soil profile pit on the parcel. <br /> ❑/ ❑ 5.2 Description of soil profile pit including depth and dimensions. <br /> [� ❑ 5.3 Description of soil lithology as noted from test pit by appropriate professional using industry standard protocol. <br /> [7� ❑ 5.4 Discussion of soil lithology as related to future onsite septic uses. <br /> S n I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> E� ❑ 6.1 Site map showing the location,with concise and accurate dimensions of the percolation test holes on the parcel. <br /> Ff ❑ 6.2 The minimum number of shallow and deep percolation tests was performed for each parcel. <br /> ❑ 6.3 Description of the date,time and protocol used to prepare the test hole, including depth and dimensions of hole, <br /> preparation of hole, and depth of water used to presoak(minimum 12 inches). <br /> [A] ❑ 6.4 Description of the date,time and condition of the test hole after the 24-hour soak period (hole still intact, hole dry, <br /> depth to water remaining in hole, etc.) <br /> E� ❑ 6.5 The test conformed to SJC Policy EHD 02-02 (correct depth, diameter,2"gravel, 6"water refill, correct readings <br /> recorded). <br /> ❑ 6.6 Complete Percolation Test Form (including readings)was provided with REHS verification signature. The rate <br /> was correctly calculated using the last reading. <br /> [7f ❑ 6.7 Discussion of any potential problems predicted and/or the need for an engineered or alternative septic system. <br /> [�/ ❑ 6.8 Discussion of percolation rates in relation to the type, size and location of future leach fields needed at the site. <br /> 7.0 CONCLUSION SECTION <br /> [�/ ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed BY: � T �� Reviewed Date: <br /> 2 t Pr <br /> EHD 26-02-003 Page 2 of 3 Soil Suitability Checklist <br /> 7/14/2003 <br />