Laserfiche WebLink
I <br /> PLUMBING SPECIFICATIONS PLUMBING GENERAL NOTES <br /> FIXTURE UNIT LOADING COMPLIANCE NOTES <br /> PART -GENERA I BEFORE COMMENCEMENT OF WORK,THE CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS, ELEVATIONS AND <br /> CHARACTERISTICS OF ALL UTILITIES AND PIPING, AND SHALL IMMEDIATELY NOTIFY THE NOR-CAL REST. DESIGN OF ANY FIXTURE DESCRIPTION QTY TOTAL WATER WASTE TOTAL WASTE ADA WATER CLOSET AND LAVATORY SHALL MEET THE AMERICAN DISABILITIE5 ACT <br /> 1.RELATED DOCUMENTS: DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND DISCREPANCIES• F.U.5 <br /> SUPPLEMENTARY CONDITIONS AND OTHER DIVISIONS- I SPECIFICATION'SELECTIONS, APPLYTO WORK OF TM5 2. THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERlAL5 SHALL CONFORM TO THE LATEST ADOPTED CODES F.U. VALUE F.U. VALUE F.U.5 GUIDELINES AND CALIFORNIA C•C.R.TITLE 24. <br /> SECTION. AND REGULATIONS HAVI,�IG JURISDICTION, INCLUDING BUT NOT LIMITED T0;THE CALIFORNIA BUILDING, MECHANICAL WATER CLOSET, GRAVITY TANK <br /> 2.5COPE, WORK5 HALL INCLUDE ALL LABOR AND MATERIALS REQUIRED FOR THE COMPLETION OF A FULLY AND PLUMBING CODES.R CASE OF CONFLICTS WITH CODES, DRAWINGS OR 5PEClFIGATIONS,THE M05T STRINGENT 2,5 2• PROVIDE PERMANENT VACUUM BREAKERS ON ALL H05E BLEBS, <br /> OPERATING PLUMBING 5Y57EM INCLUDING BUT NOT NECESSARILY LIMITED TO: ALL EXCAVATION, INSTALLATION, REQUIREMENTS SHALL PREVAIL. 6 G.P.W. 2.5 3.G' 3.0 <br /> BACK FILL AND COMPACTION;ALL REQUIRED TAXES; OBTAINING AND PAYNG FOR ALL REQUIRED LICENSES, 3. THE DRAWINGS WERE PREPARED WITH THE 5E5T STRUCTURAL AND ARCHITECTURAL iNFOKMATION AVAILABLE. IT 3. PROVIDE ANGLE STOP VALVES AT EACH SUPPLY LINE TO EACH FIXTURE, NOR-CAL <br /> PERMITS, FEE5, INSPECTIONS, METERS AND CONNECTIONS;ALL WATER DISTRIBUTION;ALL VENTS AN'D WASTES; 51ALL BE UNDERS700DT IAT EQUIPMENT LOCATIONS AND ROUTING OF PIPING MAY VARY FROM,THAT SHOWN ON LAVATORY <br /> ROOF DRAINAGE AND FLOOR DRAiNAGI=;FIXTURE5 AND ROUGH-IN AND CONNECT CONDENSATE TO THE PLANS A5 CONSTRUCTION PROCEEDS. IT IS THE CONTRACTORS RESPONSIBILITY TO: I'0 0 1.0 4• WATER CLOSETS SMALL BE LOW-CON5UMPTION I.6 GPM FLU5`1 TANK. RESTAURANT <br /> OWNER-FURNISHED AND MECHANICAL APPLIANCES, REPAVE WALKWAYS AS NECE55ARY, WORK SPECIFIED A. NOTIFY THE MEC`IAN'ICAL ENGINEER OF CONSTRUCTION RE5TRAINT5 WHICH MAKE VARIATIONS FROM <br /> EL5EWHERE: IRRIGATION AND FIRE PROTECTION S. LAVATORY FAUCETS 5HALL RESTRICT FLOW TO 2.2 GPM AND .25 GALLONS PER CYCLE. <br /> THE PLANS NECEK ARY. HAND SINK 2.0 4.0 >, DESIGN <br /> 3.SUBMITTALS:SHOP DRAWINGS: WITHIN TEN (1 0) DAYS AFTER AWARD OF CONTRACT SUBMIT TO THE ARCHITECT B. COMPLETE WORK INCLUDING THE VARIATIONS WITHOUT CHARGING EXTRAS TO THE 81D CONTRACT, �'"' <br /> SIX(6)SETS OF 5U5MITTAL5 INCLUDING CATALOG CUTS OF PLUMBING EQUIPMENT AND COMP ETE SWOP COMPLETION OF WORK MEANS THE J0515 IN GOOD WORKING ORDER AND MEETS CITY, COUNTY AND 6. SINK FAUCETS SMALL RE5TRICT FLOW TO 2.2 GPM. <br /> DRAWINGS AND MATERIALS INCLUDING THAT WHICH I5 REQUIRED BUT NOT 5PECIFIED. CODES STATED ABOVE. 3 COMP SINK <br /> 4.A5-BUILT DRAWINGS: DURING PROGRESS OF TH>E WORK MANTAIN AN ACCURATE RECORD OF ALL CHANGES MADE 4. THESE DRAWINGS DO NCT INCLUDE NECE55ARY SAFETY REQUIREMENTS.THE CONTRACTOR 5HALL COMPLY TO THE 3'0 3.0 3.0 7. MOT WATER HEATER, CONTROLS,AND SYSTEM SMALL MEET TWE REQUIREMENTS OF <br /> FROM THE PLANS, PRESENT A PROFE5510NALLY DONE REPRODUC15LE PLAN TO ARCHITECT REFLECTING GRANGES. SAFETY REQUIREMENTS A5 SET FORTH BY THE GENERAL CONTRACTOR AND LOCAL AUTHORITIE5 HAVING CALIFORNIA EFFICIENCY5TANDARD (a) <br /> 5.JOB CONDITIONS: CONTRACTOR 5HALL 055T SITE PRIOR TO BIDDING AND FULLY ACQUAINT MIM5ELF WITH JUR5DICTION. P400-92 005,SECTION ! 3 AND(b}. <br /> CONDITIONS AFFECTING INSTALLATION OF THE PROPOSED SYSTEM, VERIFY ELECTRICAL POWER REQUIREMENTS ON 5, TME5E DRAWINGS ARI=FOR BIDDING PURP05E5 ONLY,THEY ARE ESSENTIALLY DIAGRAMMATIC Td TLE EXTENT MOP SINK 8, STATE HEALTH 4 SAFETY CODE BANS THE USE OF CHLORINATED POLYVINYL CHLORIDE <br /> SITE. CONFIRM ACCE551BILJTY AND LOCATION OF SERVICES. MAINTAIN CONTINUITY OF SERVICE TO EXISTING THAT MANY OFFSETS, BONDS, UNIONS,SPECIFIC FITTING AND EXACT LOCATIONS ARE NOT INDICATED, 3.0 3 " j' (CPVC)FOR INTERIOR WATER 5UPPLY PIPING. NO CPVC PIPING WILL BE USED FOR THE EXPERTS IN RESTAURANT <br /> 5Y5TEN5 WITHOUT INCONVENIENCE OR DANGER TO PER50NNEL. POTABLE WATER SYSTEMS. DESIGN & PLANNING, OVER 30 <br /> 6. THE CONTRACTOR 5HALL MAKE ARRANGEMENTS WITH UTILITY COMPANIES FOR SERVICE AND CONNECTION AND <br /> 5HALL MAKE APPLICATION FOR SERVICE AND PERMITS IN THE NAME OF THE OWNER AND SMALL PAY ALL FEESYEARS IN THE BUSINESS <br /> FLOOR SINIKlDRAIN 2, 9. W5ULATE HOT WATER PIPING PER CALIFORNIA EFFICIENCY STANDARDS AND 2007 CPG. NORRiS J. MITCHELL <br /> AND CHARGES INCLUDING THE C05T OF M TIERS.COORDINATE INFORMATION'WIT` WATER HEATEI25 S`ALL BE SECURED AS REQUIRED BYT11E 2007 CPC, NORRIS J DESIGNER <br /> PART 2 -PRODUCTS OWNER'S REPRESENTATIVE PRIOR TO WORK. �`� <br /> PROJECT <br /> 7. PLUMBING WORK SHALL 5E INSTALLED 50 A5 TO AVOID INTERFERENCE WlTL ELECTRICAL EQUIPMENT, MECHANICAL 310 SOUTH CENTRAL PKWY <br /> 1,GENERAL: USE ONLY NEW FIR5T CLA55 MATERIALS. EQUIPMENT TO BE IDI=NTIFIED WITM NAMEPLATE. EQUIPMENT AND 5TRUCTURAL MEMBERS. 10, INSTALLATION IN5TRUCTION5 FOR ALL LISTED EQUIPMENT SMALL BE MADE AVAILABLE <br /> ELECTRICAL EQUIPMENT TO 5E UL LISTED. WHERE REQUIRED ALL TO BE STATE FIRE MAR.5TALL APPROVED. ALL 8, THE CONTRACTOR 51ALL COORDINATE THE LOCATION OF ALL CEILING ACCESS PANELS ANp SKYLIGHTS WITH TWE TO THE BUILDING INSPECTOR AT THE TIME OF INSPECTION. MTN. HOUSE, CALIFORNIA 95391 <br /> INSULATION SMALL HAVE A FLAME SPREAD OF NOT MORE THAN 25 AND A SMOKE DENSITY NOT EXCEEDING 50, ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING PLAN. PHONE NO. (209) 221-7090 <br /> 2.501L WASTE,AND VENT PIPING WITHIN BUILDINGS:SERVICE WEIG`fT CAST IRON NO-HUB SOIL PIPE UNLE55 9. COORDINATE LOCATIONS,51ZE5 AND ELEVATIONS DF 5LEEVE5 THROUGH WALLS, BEAMS,SLABS AND FOOTING WITH FAX NO. {209)221-7091 <br /> OTHERWISE NOTED. MAKE UP INT . BELOW <br /> GRAD TYPE FITTINGS AND STAINLESS STEEL CLAMP AND A SHIELD 5TRUCTURAL AND ARCHI7=CTURAL DRAWINGS. PIPE SLEEVING THROUGH FOOTING SHALL HAVE A SLEEVE DIAMETER EMAIL: nmitch9944@aol.com <br /> A55EMBLIES AND NEOPRENE JOINTS. BELOW GRADE USE BELL AND SPIGOT WITH LEAD AND OAKUM FOR WASTE <br /> FROM DRINK DISPENSERS USE DURIRON TO THE POINT WHERE CONNECTED TO SOIL PIPE, OF TWO PIPE 51ZE5 OVER THE PIPE PA551NG THROUGH THE FOOTING, COORDINATE INSTALLATION WIT"i THE <br /> 3.VENT PIPING 2 V2"512E AND SMALLER ABOVE FLOOR MAY BE 5CHEDUIE 40 GALVANIZED STEEL PIPE UP WITH STRUCTURAL ENGINEER AND DRAWINGS PRIOR TO WORK. <br /> CAST IRON DRAINAGE FITTINGS. !0. BEFORE FABRICATION OR IN5TALLATION,THE CONTRACTOR SMALL VERIFY EXACT LOCATIONS OF PROJECT <br /> 4,5EWER AND WASTE EXTERIOR: FROM FIVE FEET OUTSIDE THE BUILDINGS SERVICEWEIGHT CAST IRON PIPE WITH EQUIPMENT AND ITEMS PROVIDED BY OTHERTRADE5, EXACT ROUGH-IN LOCATION5 AND REQUIREMENTS 5WALL BE <br /> MECHANICALJOINITS. FIELD COORDINATED. TOTAL FIXTURE LOADINGI F 30 <br /> 5.ALLWIT HOT AND COLA WATER PIPING ABOVE FLOOR SHALL BE TYPE"L''ryARD-DRAWN COPPER TUBE MADE UP CONNECTION BETWEEN INCOMPATIBLE MATERIALS ABOVE GRADE AND INSIDE BUILDING SMALL BE MADE WITH TWO 30.0 REVISIONS: <br /> WITH 95-5 SOLDER. <br /> (2)DIELECTRIC UNIONS 5EPAKATED BY A TWELVE INCH(1 2")SECTION OF RED BRA55 PIPE, USE' <br /> 6.BELOW-GRADE AND BELOW-SLAB PIPING SMALL BE TYPE"K ANNEALED COPPEKTUBE MADE UP ABOVE FLOOR. 12, PIPING 5HALL 8E SUPPORTED WITH HANGERS AND BRACKETS WHICH PROVIDE ISOLATION FROM FRAMING. NOTES: USE; <br /> 7.DOMESTIC WATER PIPING BELOW GROUND OUTSIDE OF BUILDINGS SIZE %2 AND SMALLER SMALL BE PVC WFU BASED ON TOTAL DEVELOPED LENGTH OF 100 FEE("@ PRE55URE RANGE OF 60 PSI CONNECT TO (E) G"SANITARY WASTE LINE HEALTH D E PARTM ENT NOTES <br /> SCHEDULE 40, SIZE 2"AND LARGER 5HALL BE PVC SCHEDULE 80 OR CLA55 3 f 5 USING SCLEDULE 80 FITTINGS. CONTACT BETWEEN PIPING AND SUPPORT SHALL BE LINED WITH PLASTIC OR FELT. AVAILABLE STATIC PRE55URE AFTER HEAD L055(20 16 CPC-TABLE G.10), CONTRACTOR AND PROVIDE (N) VENT TO ROOF. <br /> ONLY SCHEDULE 40 MALE ADAPTERS ARE ACCEPTABLE. SET PIPE A MINIMUM OF 18' DEEP AND PROVIDE A 13. FLOOR AND WALL PENETRATION5 SMALL BE SEALED WATERTIGHT AND VERMIN PROOF. TO VERIFY EXISTING WATER SERVICE THAT MINIMUM PRE55URE AVAILABLE DOES NOT GO BELOW PROVIDE A PROTECTIVE COVER AROUND BACKSIDE OF HALF-EXPOSED FLOOR SINKS TO <br /> GROUND WIRE CONNECTING BUILDING TO METER. 14, EXTERIOR GAS COCKS,WATER 5HUTOFF VALVES AND SEWER CLEAN-OUT5 BELOW GRADE 5IALL BE INSTALLED THIS PRE55URE RANGE. CONTRACTOR SHALL NOTIFY THE ENGINEER IF THE AVAILABLE PREVENT ANY WASTE WATE <br /> 8 CONDFN5ATE DRAIN AND INDIRECT WASTE PIPING: ABOVE GRADE SMALL BE DWV COPPER WITH DWV DRAINAGE IN YARD BOXES WITL THE COVERS CONSPICUOUSLY MARKED WITH THEIR RESPECTIVE UTILITY("GAS" "WATER" PRESSURE iS BELOW TH15 RANGE. R BACK FLOW UNDER THE EQUIPMENT, <br /> TYPE FITTINGS, PVC MAY BE USED A5 APPROVED BY JURISDICTIONAL AUTHQRITIES. AND"SEWER"). FLOOR SINKS MUST BE LOCATED WITHIN 15 FEET OF T'1E DRAIN OPENING OF THE EQUIPMENT <br /> 9. GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE(ASTM A 120)WITH J 50 PSI BLACK BANDED MALLEABLE 15. EXACT LOCATION AND MOUNTING HEIGHT5 OF PLUMBING FIXTURES SMALL BE OBTAINED FROM THE SERVED. <br /> IRON SCREWED FITTINGS AND PLAIN PATTERN COUPLINGS. 1 '/2 INCHES AND LARGER FITTINGS MAY BE BUTT ARCHITECTURAL DRAWING5. <br /> WELDED. COAT AND WRAP BURIED PIPING. 16. SEE ARCHITECTURAL DRAWINGS FOR HANDICAP FIXTURE LOCATIONS AND MOUNTING HEIGHTS. INSULATE EXPOSED DFU BASED ON CPC 2016 TABLE 7-5 MAXIMUM UNIT LOADING FOR HORIZONTAL PIPING AT <br /> I OVALVES: GATE VALVES 5HALL 6E'WALWORTH", OR EQUAL, J 25 LB. SOLDER ENDS, ALL BRONZE. HO5E BIBS 0"SLOPE AND MAXIMUM UNITS FOR VENT PIPING. <br /> HOT WATER AND DRAIN PIPING BELOW HANDICAP LAVATORIES AND SINKS WITH INSULATING TAPE AND OFFSET <br /> SMALL BE"ACORN"8I E IN WALL BOX AND WALKWAYS AND 81 26 FREE STANDING. LOo5E KEY OPERATED; P-TRAP AGAINST WALL, FLUSH VALVES FOR HANDICAP FIXTURES 5HALL BE LOCATED ON THE HANDICAP FOR PLAN <br /> FINISHED WITH CHROME INSIDE AND BRONZE OUTSIDE. ALL`10SE BIBS SHALL HAVE BUILD M VACUUM WHEELCHAIR ACCESS 51DE OF THE STALL. CHECK REVIEW <br /> BREAKERS. CRANE 252 GAS COCK 5`iALL BE USED. !7, WASTE, SOIL,VENT AND CONDENSATE PIPING SHALL SLOPE AT 2 <br /> I YARD BOXES TO BE PRE-CAST CONCRETE BROOKS PRCDUCT5 WITH THE NAME OF SERVICE ON COVER. %UNLE=SS APPROVED OTHERW15E BY THE OWNER'5 ENGINEER E RECORD <br /> 2PIPE SLEEVES SHALL BE ADJUSTO-CRETE"OR EQUAL. PROVIDE B$C CHROME ESCUTCHEONS IN FINI5MED REPRESENTATIVE AND THE LOCAL AUTMORITIE5 HAVING JURISDICTION. <br /> AREAS, 18. CLEAN-OUTS SHALL BE INS-ALLED WHERE READILY ACCESSIBLE.THE CONTRACTOR 5HALL COORDINATE THE <br /> 13MANGERS AND SUPPORTS SMALL BE GRINNEL OR EQUAL, PROVIDE LATERAL BRACING WHERE HANGERS 18"LONG. CLEAN-OUT LOCATIONS WITH !fendrlk Van De Pol, F'. I , <br /> EQUIPMENT, CABINETS, ETC, PRIOR TO INSTALLATION. <br /> 150LATE HANGERS AND SUPPORTS FROM PIPING WITH 5EMCO TRI5CLATOR5, INSULATE AT OPENINGS OF 19. VALVES ,TRAP PRIMERS,WATER HAMMER ARRESTORS AND OTHER EQUIPMENT A WALLS OR NON-ACCE5SIBLE Senior Structural Engineer <br /> STRUCTURE WITH %2"FELT WRAP. CEILINGS SHALL BE INSTALLED WITH ACCESS PANELS, FIXTURE SCHEDULE 2225 Llving5ton Lane <br /> 14.VENT FLASHING AT EACH VENT TLROUGH THE ROOF 51ALL BE HEAVY AMC GALVANIZED S`IEET METAL WITH ZING 20. THE PLUMBING CONTRACTCR SMALL VI51T THE JOB 51TE AND REVIEW ENTIRE DRAWING PACKAGE PRIOR TO BASE 5tockton,Callfornia 952 10 <br /> CHROMATE COATING. BID.THE CONTRACTOR SMALL FAMILIARIZE HIMSELF WITH TME EXISTING CONDITIONS AND FUTURE WORK TO BE TAG DESCRIPTION FIXTURE BRANCH SIZE Ph: (209) G39-358 I <br /> 15CL05I HAMMER ARRESTERS 5HALL BE j.R.SMITH 5000 SERIES STAINLESS STEEL BELLOWS TYPE AT ALL QUICK DONE.THE 517E INFORMATION AND CONDITIONS REVIEWED SMALL BE SUBMITTED WITH THE BASE BID.THE BASE DESCRIPTION Fax: (209) 474-0921 <br /> CLOSING VALVES. BID 5HALL INCLUDE ITEMS,WORK REQUIRED AND COMPONENT5 NECE55ARY FOR A COMPLETE AND FULLY WASTE VENT CW HW Email: hvdutchhenk@gmall.com <br /> I GCLEANIOUT5: FLOOR CLEANOUT5:SMITH 4023,4043. GRADE CLEANOfJTS:SMITW 4253. WALL CLEANOUT5: FUNCTIONING PLUMBING SYSTEM, <br /> SMITH 4553 IN TILE WALLS AND TOILET ROOMS AND 4532 IN OTHER. ADA WAT> R CLOSET <br /> 21. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS COMPOUND BEFORE COVERING. WC FLOOR MOUNTED <br /> 17UNIONS: ISOLATE ALL DISSIMILAR METAL WITH"EPCO"DIELECTRIC UNIONS. PROVIDE NERCO 623 FOR 2"AND 22, FIXTURES SMALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS OF 5hDCK ABSORBERS. 3" 2" 314" <br /> SMALLER AND#740 FOR LARGER. FLUSH TANK <br /> 23. HORIZONTAL CONDENSATE DRAIN PIPING FROM AIR CONDITIONING UNITS SHALL BE INSULATED WIT`1 112"THICK <br /> 18ACCE55 PLATES: ACCE55 PLATE5 5HALL BE PROVIDED AT ALL CONCEALED VALVES AND EQUIPMENT, MILCOR ARMAFL-EX PIPE INSULATION OR EQUAL.5LIP PIPE INSULATION AND SEAL BUTT JOINTS. <br /> OR EQUAL, HINGED, RATED TO MATCH CONSTRUCTION, PRIME COATED STEEL(EXCEPT 55 IN TOILET ROOMS)AS 24 MOT WATER PIPING SMALL 5E 1N5ULATED WITH J-I/2"TMJCK FiBERGLA55 MOLDED INSULATION WITH K=0.27 <br /> SELECTED 5Y ARCHITECT,EQUIPPED WITH KEY LOCKING DEVICE. IN AC0U5TICAL CEILINGS PROVIDE WITH INSET <br /> TO RECEIVING CEILING TILE. BTU H-1N.5Q, FT, F. OR LE55. G <br /> ADA LAVATORY 2" !-112" 112" <br /> 1 9COMBINATION PRESSURE AND TEMPERATURE RELIEF VALVES: WATT5 REGULATOR CO. OR EQUAL ON STORAGE 25. PROVIDE PERMANENT VACUUM BREAKERS ON ALL HOSE BIBBS. "! <br /> TANKS AND WATER HEATER5 f51ZED FOR BTUH INPUT AND A5TM STAMPED). 2G. PROVIDE THERMAL EXPAN51ON OF WATER HEATER5 AND BOILERS PER THE REQUIREMENT5 OF THE CALIFORNIA PLUMBING <br /> 20FiXTURE5 AND EQUIPMENT: ALL FIXTURES AND EQUIPMENT 5HALL BE A5 SPECIFIED AND SMALL BE COMPLETE PLUMBING CODE, <br /> WITH ALL STOPS,SUPPLIES, BACKING DRAIN, CHROME PLATED BRONZE TRAM AND OTHER ITEMS NECESSARY FOR 27• NO CPVC PIPING WILL BE U5=D FOR POTABLE WATER5Y5TEM5. I NAND WASH N A <br /> A COMPLETE, OPERABLE FACILITY. FIXTURE5 SHALL BE AMERICAN STANDARD, CRANE, OR KOHLER UNLE55 SINK 1-COMP, 1 /2 1-1/2" 112" 112" SEE EQUIPMENT 5C!IEDULF ON DWG A-3 <br /> OT11ERWI5E SPECIFIED. PROVIDE VACUUM BREAKERS AT ALL SERVICE SINKS. 28. VERIFY RIGHT LAND OR LEFT HAND FIXTURE CONNECTIONS AND WATER CLOSET LEVER REQUIREMENTS PRIOR TO <br /> WORK. INSTALL FIXTURE5 AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATION5. <br /> 21 PIPE WRAPPING: COVER AND TEST ALL BURIED METAL PIPE PER AWWA 209 d 214, BOND NONCONDUCTIVE 29. 01~F5ET5$TRANSITIONS NOT SHOWN THE CONTRACTOR 5HALL PROVIDE NECE55ARY OFFSETS s REDUCERS AS SK PREP SINK WITH <br /> JOINTS AND PROVIDE CATMODIC PROTECTION A5 RECOMMENDED BYTHE SOIL5 TESTING COMPANY, (EXCEPT A5 REQUIRED FOR EACW SYSTEM IN5TALIL0ON. 31, 1-I/2" 12' /2" SEE EQUIPM NT SCHEDULE ON DWG,A-3 E <br /> REQUIRED OR ALLOWED BYTLE SOILS REPORT). IN5ULATE ALL HOT WATER PIPE ABOVE GRADE PERTITLE 24 2 DRAIN BOARD ROF SSI <br /> REQUIREMENTS, PROVIDE CANVAS FINISH AND RAND ENE 51 EDI iOT WATER PIPE BELOW GRADE 5HALL BE V GAS WATER HEATER SCHEDULE �� e 0/v <br /> WRAPPED WITH A I"MINIMUM FOAM INSULATION AND ENCASED IN PVC. SEAL PENETRATION'S OR FIRE RATED �. „A N � <br /> BARRIERS WITH 3M FIRE RATED CAULK. 5K 3 COMP SINK MANUFACTURER GPM @ ()Ode F GAS INPUT CONNECTION 10 �y <br /> 22 PROPER MATERIALS:ALL OTHER N SERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND e WITH DRAIN 3 12' 112" 112 SEE EQUIPMENT SCHEDULE ON DWG.A-3 pj Q �` O <br /> PROPER INSTALLATION, SMALL BE N'EW, FIPST QUALITY OF THEIR RESPECTIVE KINDS AND SUBJECT TO THE BOARD TAG MODEL TEMP, RISE BTU/HR GAS PIPE 512 REMARKS <br /> APPROVAL OF THE ARCLITECT. NO. O Z <br /> uj Lr = NO. 15472 1 r m <br /> M5 <br /> MOP SINK 3 /2 112" 112" 5EE EQUIPMENT SCHEDULE ON DWG A rn <br /> -3 MARCH 39,2021 <br /> PART 3-EXECUTION <br /> EXP.DATE <br /> FS <br /> I.CLEARANCES:THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC. PROVIDE EQUIPMENT CLEARANCES AND OFFSETS FLOO908-I ! 9 N ` <br /> R COMMERCIAL 2"X 12"X8" DEEP 1 2 HALF GRATE AND 902 DOME <br /> SINK 3 1 112 /2` STRAINER. SET FLOOR SINK FLUSH WITHWITH FINISHED FLOOR, PROVIDE DRAIN <br /> IN PIPING A5 NECE55ARY TO CONFORM TO 5TRUCTURE,AVOID 035TRUCTION5, PRE5ERVE HEADROOM AND KEEP WITH COVER. PROVIDE WITH 112" HARD DRAWN COPPER TRAP PRIMMER IF OF �rQ�c- <br /> PA55AGEWAY5 CLEAR AS A CONTRACT REQUIREMENT. INSTALL EQUIPMENT AND MATERIALS PER AT TAILPIECE. C A M <br /> MANUFACTURER'S REQUIR_FMENTS. EQUIPMENT 5HALL BE ACCESSIBLE FOR MAINTENANCE. <br /> 2.COORDINATION: COORDINATE THE WORK OF RAN SECTION WITH OTHER TRADES TO AVOID INTERFERENCE AND FD FLOOR DRAIN 3 /2" 112° J.R. SMITH 2005-AUP CAST IRON WITH POLISHED BRONZE TOP <br /> FOR THE GENERAL BNS PRI OF THE WORK. ARRANGE FOR AND MAKE ALL UTILITY CONNECTIONS. VERIFY e WITH TAMPER PROOF SCREWS. PROVIDE WITH I/2" HARD <br /> APPROVED LOCATIONS PRIOR TO CONSTRUCTION AND INSTALLATION, PRAWN COPPER TRAP PRIMMER AT TAILPIECE. <br /> 3•CONCEALED OF PIPES: EXCEPT WHERE SPECIFICALLY PERMITTED BY THE ARCHITECT, ROUTE ALL PIPES <br /> CONCEALED WIT`11N BUILDING CAVITIES. <br /> 4.TRENCHE5 AND BACK FILLING: PERFORM ALL TRENCHING AND BACK FILLING ASSOCIATED WITH THE PLUMBING GT 30#ABOVE GROUND GREASE TRAP,RFA5E TRAP � I J/2" /2 <br /> INSTALLATION, <br /> 5.CODE5: PERFORM ALL WORK ACCORDING TO ALL APPLICABLE CODES AND REGULATION, OBTAIN AND PAY FOR <br /> ALL PERMITS, FEES AND INSPECTIONS REQUIRED BY GOVERNING AUTHORITIES. ADDITIONAL WORK REQUIRED TOA FCO FLOOR CLEANOUT JONP5PEC SERIES 63250 WITH BRONZE CLEAN OUT COVER <br /> CONFORM TO THESE CODES WILL BE DONE AT NO ADDITIONAL CHARGE. ALL WORK TO BE DONE BY JOURNEYMAN MARKED"CLEANOUT". <br /> TRADESMEN WHO ARE FAMILIAR WITH THE CODE.GAT O <br /> &.TMOROUGHLYCLEAN PIPING BEFORE INSTALLATION. <br /> 7,UN fEET(1 U) PIPING SHALL HAVE A MINIMUM COVER OF 24". METAL PIPE 51ALL EXTENDLL <br /> TO A MINIMUM OF JONESPEC 5ERIE5 G3 1 50 WITH BRONZE CLEAN OUT COVER <br /> TEN FEET(I 0')FROM THE BUILDING, PROVIDE SLEEVES FOR PIPES PASWCO WALL CLEANOUT SING THROUGH FOOTINGS. <br /> B.PROVIDE CLAMPS OR CONCRETE THRUSTMARKED "CLEANOUT", <br /> BLOCKS ON DEAD ENDS, ANGLE5 OR AT OTHER JOINTS WHERE (- <br /> SEPARATION MAY OCCUR IN JOINTS. <br /> 9.PROVIDE FITTINGS AT ALL WATER SUPPLY OUTLETS AND CONNECTIONS TO FIXTURE5 WHICH WILL ZL HOLD THE PIPE <br /> RIGIDLYTO THE STRUCTURE AND WILL wL ALLOW NO MOVEMENT, w <br /> I OPKOVIDE A UNION ON ONE SIDE OF ALL VALVES AND AT EQUIPMENT CONNECTIONS. <br /> I 1 MAKE 5UITABLE PROVISION FOR MAXIMUM EXPAN510N AND CONTRACTION OF PIPING, NOTES: <br /> !2NO BULLHEAD TEES, CLOSE NIPPLES, OR BUSHINGS WILL BE ALLOWED, WO Z <br /> L 3GU5MION ALL TRAPS AND 5EARING5 TO MINIMIZE TRANSFER OF SOUND, AND PROVIDE WATER HAMMER I. COORDINATE FIXTURE REQUIREMENTS WITH PLUMBING 0 O <br /> DESIGN DRAWINGS AND NOR-CAL DESIGN PRIOR TO BID. � <br /> 5TER5 AT QUICK CLOSING VALVES. 2. CONTRACTOR TO SECURE APPRDVAL WITH OWNER FIXTURE TYPE AND MODEL NUMBER OP PLUMBING FIXTURE PRIOR TO ORDER. <br /> I4SLOPE ALL WASTE, DRAIN AND SEWER PIPING AT I/a INCH PER FOOT UNLESS OTHERWISE NOTED OR PERMITTED, CZ � <br /> 15PROVIDE TRAP PRIMERS TO ALL FLOOR DRAIN5 AND OT'1ER INFREQUENTLY USED TRAPS PER LOCAL <br /> 3. ALL PLUMBING FIXTUR SHOWN ARE FOR BIDDING PURPOSES ONLY,OWNERJARCHITECT WILL APPROVE MODEL,TYPE 0- <br /> REQUIREMENTS. AND COLOR DF PLUMBING FIXTURE. <br /> 1 GCLJ71NG AND PATCHING: DO ALL DRILLING CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF THE < < <br /> IE � 0 <br /> SAME MATERIALS AND WORKMANSHIP A5 THE ORIGINAL WORK. Z <br /> 17VERIFY FIXTURE AND EQUIPMENT LOCATIONS AND SERVICE WITH ALL THE ARCHITECTURAL PLANS AND FURNISH Q ¢ V <br /> AND CONNECT FIXTURES AND EQUIPMENT SHOWN THEREON. EQUIPMENT 5HALL BE 5ECURFLY ANCHORED TO THE PLUMBING LEGEND z <br /> STRUCTURE. W <br /> I BWALL-HUNG FIXTURES ON STUD WALLS 5HALL BE SECURELY ATTACHED TOA%�-THICK BY 8"WIDE STEEL PLATE O ❑ <br /> WHICH SHALL EXTEND TO AT LEAST ONE STUD BEYOND THE FIRST AND LAST FIXTURE MOUNTING POINT, PLATE _ ^ Q Z <br /> SMALL BE SHOP DRILLED WITH HOLE5 1/1 G"LARGER THAN 5TUD 5OLT5 SUPPLIED WITH FIXTURE OR FIXTURE SYMBOL ABBREV. DESCRIPTION ABBREV. DESCRIPTION' V/1 O <br /> ARMS SPECIFIED, A JAM NUT 5WALL BE 5ET TIGHT AGAINST FACE PLATE To SECURE STUD. FIXTURE MANGER <br /> SM ARM 51ALL E SUPPORTED FREE OF FINISHED WALL BY MEANS OF SECOND SET OF JAM NUTS. PATES 55 55 SEWER OR WASTE AFF ABOVE FINISHED FLOOR W J O <br /> SMALL BE SECURELY BOLTED TO EACH STUD GROSSED WITH I•8"MINIMUM O T STEEL BACKUP PLATES. AIG ABOVE GRADE z w �) <br /> FIXTURES WITH ANGER 5PECIFIED WITH SUPPORTING ARMS,SMALL, IN ADDITION TOT E ABOVE SPECIFIED PLATES, V V VENT Q ---,5 W <br /> HAVE FIXTURE HANGERS SECURELY ATTACHED 8Y A 2'8Y 8"WOOD BACKINGS. ACCU AIR COOLED CONDENSING UNIT REFRIGERATION = W J <br /> !9EACH INDIVIDUAL FIXTURE SUPPLY 5HALL BE PROVIDED WITH CHROMIUM PLATED L005E KEY 1.P.5. STOP VALVE. CW COLD WATER BIG BELOW GRADE w J Q <br /> DELIVER L005E KEYS ET THE OWNER. NO RUBBER PACKING OR COMP051TLON SEAL SHALT BE INSTALLED. CD CONDENSATE DRAW � U � � U <br /> SUPPLIES SMALL BE METAL TO METAL ONLY. HW HOT WATER DN DOWN W <br /> 20PROVIDE PIPING CONNECTIONS TO EQUIPMENT PROVIDED UNDER THE AIR CONDITIONING SECTION. DWV DRAIN, WASTE AND VENT O J Z 0 <br /> 2!AFTER PRE NT RECOAPY PURGING IOOff THE SYSTEM CHLORINATE THE ENTIRE POTABLE WATER W ACCORDANCE WITH MWR HOT WATER RETURN DWV EVAPORATOR REFRIGERATION 0- U <br /> THE CURRENT RECOMMENDATIONS OF THE AMERICAN'WATER WORKS ASSOCIATION, CHLORINATE ONLY WHEN THE O �* z <br /> BUILDINGS ARE UNOCCUPIED. T fFN THOROUGHLY FLUSH THE ENTIRE POTABLE WATER SYSTEM. GCO GROUND CLEAN-OUT tE) EXISTING 0 © a <br /> 22FLU5H WATER SYSTEMS CLEAN AND MAKE ALL TE5TS REQUIRED BY JURISDICTIONAL AUTHORITIES. MAKE (F) FUTURN <br /> ADJU5TMENT5 REQUIRED TO EUIONATE NOISE AND VIBRATION AS REQUIRED FDR APPROVAL BY THE ARCHITECT. FCO 00 FLOOR CLEAN-OUT U (V <br /> 235HORE AND PROTECT ALL EX5TING PIPING AND MATERIALS ENCOUNTERED DURING CONSTRUCTION, MATERIALS FU FIXTURE UNIT <br /> TO BE REMOVED 5HALL BECOME THE PROPERTY OF THE CONTRACTOR. II WCO WALIIMORIZONTAL CLEAN-OUT FT FLU5M TANK <br /> 245EAL PENETRATIONS OF RATED BARRIERS BY PIPE AND WIRE WITH 3M FIRE BARRIER CAULK, FD FLOOR DRAIN <br /> 25DAMAGED AND UNUSED MATERIALS 51'1ALL BECOME THE PROPERTY OF THE CONTRACTOR AND 5LALL BE REMOVED ---�-� M5 H05E 151135F5 FLOOR SINK <br /> FROM THE SITE, <br /> -� PIPE UP K5 KITCHEN SINK <br /> R 4-GUARANTEES <br /> GPF GALLONS PER FLU5M <br /> PIPE DOWN GPM GALLONS PER MINUTE <br /> I.MATERIALS AND EQUIPMENT PROVIDED AND/OR INSTALLED UNDER T1­1I5 SECTION SLALL BE GUARANTEED FOR A S.O.V. SHUT-OFF VALVE GW GREASE WASTE <br /> PERIOD OF ONE(1)YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE WORK BYTHE OWNER. L LAVATORY <br /> -■ WWA WATER HAMMER ARRESTOR P51 POUNDS PER 5QUARE INC.`1 F020-01 <br /> BFP BACK FLOW PREVENTER QTY QUANTITY <br /> SK SINK N. J. M.G.U. GATE VALVE T t P TEMPERATURE AND PRE55URE <br /> P.O.C. POINT OF CONNECTIONTYP TYPICALARY 2020vrR VENT TBO Roof 5HOWN <br /> G G GA5 PIPING VB VALVE BOXGV GA5 VALVE WC WATER CLOSET <br /> SYMBOLS, ABBREVIATIONS AND NOTES ARE FOR GENERAL USE, <br /> DISREGARD THOSE WHICH ARE NOT USED ON THE DRAWINGS. <br /> � D <br /> L _ o <br /> SHEET G OF 15 <br />