COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NEWTON
>
3931
>
2800 - Aboveground Petroleum Storage Program
>
PR0515675
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2022 8:43:47 AM
Creation date
4/20/2022 10:30:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0515675
PE
2832
FACILITY_ID
FA0009366
FACILITY_NAME
GILLIES TRUCKING INC
STREET_NUMBER
3931
STREET_NAME
NEWTON
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
13207017
CURRENT_STATUS
01
SITE_LOCATION
3931 NEWTON RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GILLIES TRUCKING INC 3931 NEWTON RD, STOCKTON March 28, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CFR 112.1(b)(3), 112.2 Failed to properly close tanks under the definition of"Permanently Closed". <br /> OBSERVATION:A white metal tank that previously held diesel is not in use but has not been properly closed. The <br /> tank was missing a sign that says"Permanently Closed"and a date. <br /> REGULATION GUIDANCE: When a tank is not in use, it must be permanently closed by meeting the following <br /> conditions: <br /> -remove all liquid and sludge from each container and connecting line <br /> -disconnect and blank off all connecting lines and piping have from the tank/container <br /> -close and lock all valves <br /> -post a sign conspicuously stating that it is a permanently closed container and denoting the date of closure. <br /> CORRECTIVE ACTION: Tanks that are not being used or are not addressed in the Spill Prevention, Control, and <br /> Countermeasure(SPCC)Plan must either be included in your plan or meet the permanent closure requirements <br /> noted above. Provide verification to the EHD of proper closure of the tanks. <br /> This is a minor violation. <br /> 620 CFR 112.7(f)(1) Failed to train personnel on all discharge prevention details listed in this section. <br /> OBSERVATION: Page 13 of the SPCC plan requires annual training records to be maintained. No training records <br /> were available for review during the inspection. <br /> REGULATION GUIDANCE: (f)(1)At a minimum,train your oil-handling personnel in the operation and maintenance <br /> of equipment to prevent discharges; discharge procedure protocols; applicable pollution control laws, rules, and <br /> regulations; general facility operations; and,the contents of the facility SPCC Plan. <br /> CORRECTIVE ACTION: Immediately provide adequate training to all oil handling personnel and submit a copy of <br /> the training log and training content to the EHD. <br /> This is a Class II violation. <br /> FA0009366 PR0515675 SCO01 03/28/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 5 of 8 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.