Laserfiche WebLink
Structural support: The tank is supported by the 8"thick reinforced <br /> concrete base. <br /> Other identifying features: None <br /> Piping and ancillary equipment (pumps): 191(g)(2)(C&D)/l 92(k)(2)(C&D) <br /> Piping Material of Construction: <br /> Type L Copper Tubing <br /> Pump location: <br /> Pump is attached to the cinder block wall on the south <br /> side of the main service bay. <br /> Piping/Tubing Diameter: <br /> 1 1/8" OD, 1" ID <br /> Pump type/capacity: <br /> 42 GPM <br /> Material Storage: <br /> Materials and characteristics: 191(g)(7)/192(k)(8) <br /> Stored liquids in the waste oil storage tank are a mixture of various <br /> viscosity used motor oils. All of these are classified as type IIIB <br /> flammable and combustible liquids per Table B.1 of NFPA Code 30A.. <br /> These liquids have the following HMIS Hazard Ratings: <br /> Health: I (slight) <br /> Flammability: I (slight) <br /> Reactivity: 0 (minimal) <br /> Used motor oil is compatible with the steel tank liner and does not pose <br /> any potential for corrosive damage to the tank or ancillary equipment. <br /> Specific Gravity: 0.91 <br /> Operating Capacity: 500 gallons <br /> Lodi Ilonda 3 TiLle 22 Waste Oil Assessinetil <br />