FALIOFCSeptember 2021SS T A TEERIILCWCENH OC28388AIRNL EWOITARCHEDAILLIMECT Checked By:Drawn By:Project No.:LDA Partners, Inc.Designers & Architects222 Central CourtStockton, CA 95204209.943.0405www.ldapartners.comClient:Project:Architect:450 COMMERCE COURT,MANTECA, CA. 953366/3/2021 5:08:19 PMACCESSIBILITY STANDARDSG4.00AuthorChecker727-01-18PERMIT SUBMITTAL #206/02/2021MACHADO SPORTS PARK1020 MARSH CREEKEBMA INVESTMENTSMANTECA, CA 953368 THE PROTECTED AREA WITHIN WHICH A DRINKING FOUNTAIN IS LOCATEDSHALL BE 32" WIDE MINIMUM AND 18 INCHES DEEP MINIMUM AND SHALLCOMPLY WITH CBC 11B-305.7LOCKERS1. AT LEAST ONE LOCKER AND NOT LESS THAN 5% OF ALL LOCKERS SHALL BEMADE ACCESSIBLE TO PERSONS WITH DISABILITIES. (SECTION 11B-225.2.1)2. A CLEAR FLOOR SPACE OF AT LEAST 30 INCHES BY 48 INCHES THAT ALLOWSEITHER A FORWARD OR PARALLEL APPROACH BY A PERSON USING AWHEELCHAIR SHALL BE PROVIDED. (SECTION 11B-305)3. HEIGHT: FOR FORWARD APPROACH, THE MAXIMUM HIGH FORWARD REACHSHALL BE 48 INCHES AND THE MINIMUM LOW FORWARD REACH IS 15 INCHES..FOR PARALLEL APPROACH, THE MAXIMUM HIGH SIDE REACH SHALL BE 48INCHES AND THE LOW SIDE REACH SHALL BE MINIMUM 15 INCHES ABOVE THEFLOOR. (SECTION 11B-308)4. HARDWARE: LATCH & LOCKING HARDWARE SHALL BE OPERABLE WITH ONEHAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTINGOF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BENO GREATER THAN 5 POUNDS OF FORCE. (SECTION 11B-309.4)ACCESSIBILITY SIGNAGE1. INTERNATIONAL SYMBOL OF ACCESSIBILITY: THE FOLLOWING ELEMENTSAND SPACES OF ACCESSIBLE FACILITIES SHALL BE IDENTIFIED BY THEINTERNATIONAL SYMBOL OF ACCESSIBILITY:A.ACCESSIBLE PARKING SPACES.B.ACCESSIBLE AREA OF REFUGE.C.ACCESSIBLE PASSENGER LOADING ZONES.D.ACCESSIBLE TOILET AND BATHING FACILITIES.E.ALL MAIN ENTRY DOORS.2. OTHER SIGNS: INACCESSIBLE BUILDING ENTRANCES, INACCESSIBLE PUBLICTOILETS AND BATHING FACILITIES, AND ELEVATORS NOT ON ANACCESSIBLE ROUTE SHALL BE PROVIDED WITH DIRECTIONAL SIGNAGEINDICATING THE ROUTE TO THE NEARST SIMILAR ACCESSIBLE ELEMENT(SECTIONS 11B-216.3, 11B-216.6 AND 11B-216.9.2))A.AT EXITS SERVING A REQUIRED ACCESSIBLE SPACE, BUT NOT PROVIDINGAN APPROVED ACCESSIBLE MEANS OF EGRESS, SIGNS SHALL BE INSTALLEDINDICATING THE LOCATION OF ACCESSIBLE MEANS OF EGRESS. (SECTION11B-216.4.3)3. DESIGN: THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THESTANDARD USED TO INDENTIFY FACILITIES THAT ARE ACCESSIBLE TO ANDUSABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN THESEBUILDING STANDARDS AND AS SPECIFICALLY REQURED IN THESE NOTES(SECTION 11B-703.7.2.1).4. COLOR OF SYMBOL: THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF AWHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TOCOLOR NO. 15090 IN FEDERAL STANDARD 595B. (SECTION 11B-703.7.2.1)A.EXCEPTION: THE APPROPRIATE ENORCEMENT AGENCY MAY APPROVESPECIAL SIGNS AND IDENTIFICATION NECESSARY TO COMPLEMENT DECOROR UNIQUE DESIGN WHEN IT IS DETERMINED THAT SUCH SIGNS ANDIDENTIFICATION PROVIDE ADEQUATE DIRECTION TO PERSONS WITHDISABILITIES.(SECTION 11B-703.7.2.1, EXCEPTION)5. CONTRAST AND FINISH: CHARACTER AND SYMBOLS SHALL CONTRAST WITHTHEIR BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. THE(FINISH OF) CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL,MATTE, OR OTHER NON-GLARE FINISH (SECTION 11B-703.5.1 AND 11B-703.7.1).6. PROPORTIONS: CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THEWIDTH OF THE UPPERCASE LETTER "O" IS 60 PERCENT MINIMUM AND 110PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I" (SECTION11B-703.5.4).7. CHARACTER HEIGHT: MINIMUM CHARACTER HEIGHT SHALL COMPLY WITHTABLE 11B-703.5.5. VIEWING DISTANCE SHALL BE MEASURED AS THEHORIZONTAL DISTANCE BETWEEN THE CHARACTER AND AN OBSTRUCTIONPREVENTING FURTHER APPROACH TOWARDS THE SIGN. CHARACTER HEIGHTSHALL BE BASED ON THE UPPERCASE LETTER "I" (SECTION 11B-703.5.5).8. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS ANDSPACES, RAISED LETTERS SHALL ALSO BE PROVIDED AND SHALL BEACCOMPANIED BY BRAILLE (SECTION 11B-703.2).9. RAISED CHARACTERS AND PICTORIAL SYMBOL SIGNS: WHEN RAISEDCHARACTERS OR SYMBOLS ARE USED, THEY SHALL CONFORM TO THEFOLLOWING REQUIREMENTS (11B-703.2 AND 11B-703.4).A.CHARACTER TYPE: LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32INCH MINIMUM AND SHALL BE SANS-SERIF UPPERCASE CHARACTERSACCOMPANIED BY GRADE 2 BRAILLE. (SECTION 11B-703.2.1, 11B-703.2.3 AND11B-703.3)B.CHARACTER SIZE: RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUMOF 5/8 INCH HIGH TO A MAXIMUM HEIGHT OF 2 INCHES. (SECTION11B-703.2.5)C.PICTORIAL SYMBOL SIGNS (PICTOGRAMS NONGEOMETRIC): PICTORIALSYMBOL SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIED BY THE EQUIVALENTVERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THEBORDER DIMENSION OF THE PICTOGRAM SHALL BE A MINIMUM OF 6 INCHESIN HEIGHT. (SECTION 11B-703.6.1)D.CHARACTER PLACEMENT: CHARACTERS AND BRAILLE SHALL BE IN AHORIZONTAL FORMAT. BRAILLE SHALL BE PLACED A MINIMUM OF 3/8 INCHAND A MAXIMUM OF 1/2 INCH DIRECTLY BELOW THE TACTILE CHARACTERS(FLUSH LEFT OR CENTERED). WHEN TACTILE TEXT IS MULTILINED, ALLBRAILLE SHALL BE PLACED TOGETHER BELOW ALL LINES OF TACTILE TEXT.(SECTION 11B-703.3.2)10. BRAILLE: CONTRACTED (GRADE 2) BRAILLE SHALL BE USED WHEREVERBRAILLE IS REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTSSHALL BE 1/10 INCH ON CENTER IN EACH CELL WITH 2/10 INCH SPACEBETWEEN CELLS DOTS SHALL BE RAISED A MINIMUM OF 1/40 INCH ABOVETHE BACKGROUND. BRAIL DOTS SHALL BE DOMED OR ROUNDED (TABLE11B-703.3.1).11. MOUNTING LOCATION AND HEIGHT: WHERE PERMANENT IDENTIFICATIONSIGNS ARE PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BEINSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR ONTHE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE.WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLELEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL,PREFERABLY ON THE RIGHT. SIGNS CONTAINING TACTILE CHARACTERSSHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES MINIMUMBY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, ISPROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSEDPOSITION AND 45 DEGREE OPEN POSITION. TACTILE CHARACTERS ONSIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOROR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWESTBRAILLE CELLS AND 60 INCHES MAXIMUM ABOVE FINISH FLOOR OR GROUNDSURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISEDCHARACTERS. (SECTION 11B-703.4.1 AND 11B-703.4.2).12. ENTRANCE SIGNS: ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO ANDUSABLE BY PERSONS WITH DISABILITIES SHALL BE INDENTIFIED WITH ATLEAST ONE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN AND WITHADDITIONAL DIRECTIONAL SIGNS (UTILIZING THE SYMBOL), AS REQUIREDAT JUNCTIONS WHERE THE ACCESSIBLE ROUTE OF TRAVEL DIVERGES FROMTHE REGULAR CIRCULATION PATH, TO BE VISIBLE TO PERSONS ALONGAPPROACHING CIRCULATION PATHS. (SECTION 11B-216.6)BLEACHERS1. BLEACHERS, GRANDSTANDS AND FOLDING AND TELESCOPIC SEATING, THATARE NOT BUILDING ELEMENTS, SHALL COMPLY WITH ICC 300 PER CBC1028.1.14. WARNING CURBS: ABRUPT CHANGES IN LEVEL, EXCEPT BETWEEN A WALK ORSIDEWALK AND AN ADJACENT STREET OR DRIVEWAY, EXCEEDING 4 INCHESIN A VERTICAL DIMENSION, SUCH AS AT PLANTERS OR FOUNDATIONSLOCATED IN OR ADJACENT TO WAKS, SIDEWALKS OR OTHER PEDESTRIANWAYS, SHALL BE INDENTIFIED BY CURBS PROJECTING AT LEAST 6 INCHES INHEIGHT ABOVE THE WALK OR SIDEWALK SURFACE TO WARN THE BLIND OF APOTENTIAL DROP OFF. WHEN A GUARDRAIL OR HANDRAIL IS PROVIDED,NO CURB IS REQUIRED WHEN A GUIDE RAIL IS PROVIDED CENTERED 2INCHES MINIMUM AND 4 INCHES MAXIMUM ABOVE THE SURFACE OF THE WALKOR SIDEWALK. (SECTION 11B-303.5).5. PROVIDE A LEVEL AREA NOT LESS THAN REQUIRED (TABLE AND FIGURE11B-404.2.4.1).6. WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL AREAS AT LEAST 5FEET IN LENGTH AT INTERVALS OF 400 FEET MAXIMUM (SECTION 11B-403.7).7. A 36 INCH WIDE DETECTABLE WARNING MATERIAL SHALL BE PROVIDED ATBOUNDARIES BETWEEN WALKWAYS AND VEHICULAR WAYS. MATERIAL SHALLCOMPLY WITH SECTION 11B-705.1.1SANITARY FACILITIES IDENTIFICATION1. DOORWAYS LEADING TO MEN'S SANITARY FACILITIES SHALL BEINDENTIFIED BY AN EQUILATERAL TRIANGLE 1/4 INCH THICK WITH EDGES 12INCHES LONG AND A VERTEX POINTING UPWARD. WOMEN'S SANITARYFACILITIES SHALL BE IDENTIFIED BY A CIRCLE, 1/4 INCH THICK AND 12INCHES IN DIAMETER. UNISEX SANITARY FACILITIES SHALL BE IDENTIFIEDBY A CIRCLE 1/4 INCH THICK, 12 INCHES IN DIAMETER WITH A 1/4 INCHTHICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12 INCHDIAMETER. THESE GEOMETRIC SYMBOLS SHALL BE CENTERED ON THE DOORAT A HEIGHT OF 60 INCHES AND THEIR COLOR AND CONTRAST SHALL BEDISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE DOOR.2. SEE ACCESSIBLITY SIGNAGE CRITERIA FOR ADDITIONAL REQUIREMENTS.BATHING AND TOILET FACILITIES1. PASSAGEWAYS LEADING TO SANITARY FACILITIES SHALL HAVE A CLEARACCESS AS SPECIFIED IN SECTION 11B-402. ALL DOORWAYS LEADING TOSUCH SANITARY FACILITIES SHALL HAVE:A.AN UNOBSTRUCTED CLEAR OPENING WIDTH OF 32 INCHES (813 MM).B.A LEVEL AND CLEAR AREA NOT LESS THAN REQUIRED (TABLE AND FIGURE11B-404.2.4.1)2. BATHING FACILITIES ( NOT APPLICABLE).3. TOILET FACILITIES ( SECTION 11B-603).A.MULTIPLE-ACCOMMODATION TOILET FACILITITIES SHALL HAVE THEFOLLOWING:1. CLEAR SPACE: A WATER CLOSET FIXTURE LOCATED IN A COMPARTMENTSHALL PROVIDE A MINIMUM 17 INCHES AND 18 INCHES MAXIMUM FROM THECENTERLINE OF THE WATER CLOSET TO THE WALL, EXCEPT THAT THE WATERCLOSET SHALL BE A MINIMUM 17 INCHES AND 19 INCHES MAXIMUM FROM THECENTERLINE OF WATER CLOSET TO THE WALL IN AMBULATORY ACCESSIBLETOILET COMPARTMENTS. A MINIMUM 48 INCHES LONG CLEAR SPACE SHALLBE PROVIDED IN FRONT OF THE WATER CLOSET IF THE COMPARTMENT HASAN END-OPENING DOOR (FACING THE WATER CLOSET). A MINIMUM 60 INCHLONG CLEAR SPACE SHALL BE PROVIDED IN A COMPARTMENT WITH THEDOOR LOCATED AT THE SIDE AND OPENING OUT. GRAB BARS SHALL NOTPROJECT MORE THAN 3 INCHES IN THE CLEAR SPACES AS SPECIFIED ABOVE.2.COMPARTMENT DOORS: WATER CLOSET COMPARTMENT SHALL BE EQUIPPEDWITHA DOOR THAT HAS AN AUTOMATIC-CLOSING DEVICE, AND SHALL HAVE ACLEAR, UNOBSTRUCTED OPENING WIDTH OF 32 INCHES WHEN LOCATED ATTHE END AND 34 INCHES WHEN LOCATED AT THE SIDE WITH THE DOORPOSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION(SECTION 11B-604.8.1.2).3. THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPEDWITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH,MOUNTING HEIGHT OF 34 INCHES TO 44 INCHES A.F.F. THE LATCH SHALL BEFLIP-OVER STYLE, SLIDING, OR OTHER HARDWARE NOT REQUIRING THEUSER TO GRASP OR TWIST. EXCEPT FOR DOOR-OPENING WIDTHS ANDDOOR SWINGS, A CLEAR, UNOBSTRUCTED ACCESS OF NOT LESS THAN 44INCHES SHALL BE PROVIDED TO WATER CLOSET COMPARTMENTS DESIGNEDFOR USE BY PERSONS WITH DISABILITIES AND THE SPACE IMMEDIATELY INFRONT OF A WATER CLOSET COMPARTMENT SHALL NOT BE LESS THAN 48INCHES (1219 MM) AS MEASURED AT RIGHT ANGLES TO COMPARTMENT DOORIN ITS CLOSED POSITION.4. GRAB BARSA.LOCATION: GRAB BARS LOCATED ON EACH SIDE, OR ONE SIDE AND THEBACK OF THE ACCESSIBLE TOILET STALL OR COMPARTMENT, SHALL BESECURELY ATTACHED 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVEAND PARALLEL TO THE FLOOR. SIDE GRAB BARS SHALL BE 42 INCHESMINIMUM LOCATED 12 INCHES MAXIMUM FROM REAR WALL, EXTENDING 54INCHES MINIMUM FROM THE REAR WALL WITH THE FRONT END POSITIONED24 INCHES IN FRONT OF THE WATER CLOSET STOOL. REAR GRAB BARSSHALL BE 36 INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OFWATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES MINIMUMON THE OTHER SIDE(SECTIONS 11B 609.4., 11B-604.5.1 AND 11B-604.5.2).B.DIAMETER OR WIDTH: THE DIAMETER OR WIDTH OF THE GRIPPINGSURFACES OF A GRAB BAR SHALL BE 1-1/4 INCHES TO 2 INCHES (32 MM TO38 MM) OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE.IF GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEENTHAT WALL AND GRAB BARS SHALL BE 1-1/2 INCHES (38 MM). SEE FIGURE11B-609.2.2 (11B-609.2).C.STRUCTURAL STRENGTH: THE STRUCTURAL STRENGTH OF GRAB BARS, TUBAND SHOWER SEATS, FASTENERS, AND MOUNTING DEVICES SHALL MEET THEREQUREMENTS IN SECTIONS 11B-609.8. GRAB BARS SHALL NOT ROTATEWITHIN THEIR FITTINGS. (SECTION 11B-609.6)D.SURFACE: A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO ITSHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVEA MINIMUM RADIUS OF 1/8 INCH (3.2 MM). (SECTION 11B-609.5)5. TOILET ROOM FIXTURES AND ACCESSORIESA.LAVATORY FIXTURES: A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHESSHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW A FORWARDAPPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP ANACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 INCHES INTO KNEEAND TOE SPACE UNDERNEATH THE LAVATORY. (SECTIONS 11B-305.3 AND11B-306.2.2, EXCEPTION)B.MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTIVESURFACE NO HIGHER THAN 40 INCHES FROM THE FLOOR. MIRRORS NOTLOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE MOUNTED WITHTHE BOTTOM EDGE OF THE REFLECTIVE SURFACE NO HIGHER THAN 35 INCHESFROM THE FLOOR (SECTION 11B-603.3).C.WHERE TOWEL, SANITARY NAPKINS,, WASTE RECEPTACLE, AND OTHERSIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEASTONE OF EACH TYPE SHALL BE LOCATED WITH ALL OPERABLE PARTS,INCLUDING COIN SLOTS, WITHIN 40 INCHES FROM THE FINISHED FLOOR(SECTION 11B-603.5).D.TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL WITHIN 7-9INCHES OF THE FRONT EDGE OF THE TOILET SEAT, MOUNTED BELOW THEGRAB BAR, AT A MINIMUM HEIGHT OF 19 INCHES. DISPENSERS THATCONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOWSHALL NOT BE USED. LIMIT THE PROJECTION OF A SURFACE ORSEMI-RECESSED MOUNTED DISPENSER FROM ENCROACHING MORE THAN 3INCHES FROM THE FACE OF THE WALL OR PARTITION, AND NO CLOSER THAN1-1/2 INCHES TO THE TANGENT POINT OF THE GRAB BAR (SECTION 11B-604.7).E.WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR FLOORSPACE 30 INCHES BY 48 INCHES IN FRONT OF THE URINAL TO ALLOWFORWARD APPROACH (SECTION 11B-605.3).DRINKING FOUNTAINS1. THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATEDSYSTEM THAT IS FRONT MOUNTED OR SIDE MOUNTED AND LOCATED WITHIN6 INCHES OF THE FRONT EDGE OF THE FOUNTAIN OR AN AUTOMATICELECTRICALLY CONTROLLED DEVICE. CBC 11B-602.32. THE SPOUT SHALL BE LOCATED 15 INCHES MINIMUM FROM THE VERTICALSUPPORT AND 5 INCHES MAXIMUM FROM THE FRONT EDGE OF THE UNIT,INCLUDING BUMPERS PER CBC 11B-602.53. THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES HIGH MINIMUM ANDSHALL BE LOCATED 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT. THEANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLYRELATIVE TO THE FRONT FACE OF THE UNIT PER CBC 11B-602.64. WHERE THE SPOUTS ARE LOCATED LESS THAN 3 INCHES OF THE FRONT OF THEUNIT THE ANGLE OF THE WATER STREAM SHALL BE 30 DEGREES MAXIMUM PERCBC 11B-602.65. WHERE THE SPOUTS ARE LOCATED BETWEEN 3 INCHES AND 5 INCHESMAXIMUM FROM THE FRONT OF THE UNIT, THAN ANGLE OF THE WATER STREAMSHALL BE 15 DEGREES MAXIMUM PER CBC 11B-602.66 THE SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONSSHALL BE 38 INCHES MINIMUM AND 43 INCHES MAXIMUM ABOVE THEFINISHED FLOOR OR GROUND PER CBC 11B-602.77 WALL AND POST MOUNTED CANTILEVERED DRINKING FOUNTAINS SHALL BE 18INCHES MINIMUM AND 19 INCHES MAXIMUM IN DEPTH PER CBC 11B-602.8DOORS & HARDWARE1. ALL ENTRANCES AND EXTERIOR GROUND-FLOOR EXIT DOORS TO BUILDINGSAND FACILITIES SHALL BE MADE ACCESSIBLE TO PERSONS WITHDISABILITIES. DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32INCHES WITH THE DOOR OPEN 90 DEGREES, MEASURED BETWEEN THE FACEOF THE DOOR AND THE OPPOSITE STOP (SECTIONS 1008.1.1, 11B-404.2 AND11B-404.2.3).2. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN34 INCHES AND 44 INCHES ABOVE THE FLOOR. LATCHING AND LOCKINGDOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVELSHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER-TYPE HARDWARE,PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNEDTO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY OT GRASP THEOPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE INEGRESS DIRECTION (SECTIONS 1008.1.9 AND 11B-404.2.7).3. PANIC HARDWARE: WHERE INSTALLED, SHALL COMPLY WITH THEREQUIREMENTS OF CBC 1008.1.10.1. THE ACTIVATING MEMBER SHALL BEMOUNTED AT A HEIGHT OF NOT LESS THAN 34 INCHES OR MORE THAN 44INCHES ABOVE THE FLOOR. THE UNLATCHING FORCE SHALL NOT EXCEED 15POUNDS WHEN APPLIED IN THE DIRECTION OF TRAVEL. (SECTION 1008.1.10,1008.1.10.1, AND 11B-404.2.9).4. WIDTH AND HEIGHT: EVERY REQUIRED EXIT DOORWAY SHALL BE OF A SIZEAS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET INWIDTH AND NOT LESS THAN 6 FEET, 8 INCHES IN HEIGHT WHEN INSTALLED INEXIT DOORWAYS. EXIT DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE EXITWAY IS NOT LESS THAN 32 INCHES (SECTIONS 1008.1.1 AND 11B-404.2.).5. HINGED DOORS: THE OPENING WIDTH SHALL BE MEASURED WITH THE DOORPOSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALLMEET THIS OPENING REQUEMENT. REVOLVING DOORS SHALL NOT BE USEDAS A REQUIRED ENTRANCE FOR PERSONS WITH DISABILITIES (SECTIONS11B-404.2.1, 11B-404.2.2 AND 11B-404.2.3).6. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL NOT EXCEED 48INCHES (SECTION 1008.1.1).7. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOREXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, SUCH PULL ORPUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND ATTHE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATINGDEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THEABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUMEFFORT TO OPERATE THE DOOR MAY BE INCREASED NOT TO EXCEED 15POUNDS (SECTIONS 1008.1.3, 1008.1.3.1 AND 11B-404.2.9).8. DOOR AND GATE SURFACES: SWINGING DOOR AND GATE SURFACES WITHIN10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALLHAVE A SMOOTH SURFACES ON THE PUSH SIDE EXTENDING THE FULL WIDTHOF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICALJOINTS IN THESE SURFACES SHALL BE WITHIN 1/16" INCH OF THE SAMEPLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES.CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED (SECTIONS11B-404.2.10).9. THRESHOLDS SHALL NOT EXCEED 1/2 INCHES IN HEIGHT, WITH A MAXIMUM1/4-INCH VERTICAL AND CHANGES IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCHSHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 (50% SLOPE)(SECTION 11B-404.2.5).10. EXIT DOORS FROM GROUP 'A' OCCUPANCY SHALL NOT BE PROVIDED WITH ALATCH OR LOCK UNLESS IT IS PANIC HARDWARE (SECTION 1008.1.10).11. RECESSED DOORMATS SHALL BE ADEQUATELY ANCHORED TO PREVENTINTERFERENCE WITH WHEELCHAIR TRAFFIC (SECTION 11B-302.1 AND11B-302.2).12. ALL GATES, INCLUDING TICKET GATES, SHALL MEET ALL APPLICABLESPECIFICATIONS FOR DOORS (SECTION 11B-404.1 AND 11B-404.2).13. DOOR CLOSING SPEED: DOOR AND GATE CLOSING SPEED SHALL COMPLYWITH SECTION 11B-404.2.8. DOOR CLOSERS AND GATE CLOSERS SHALL BEADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGRESS, THE TIMEREQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THELATCH IS 5 SECONDS MINIMUM. DOOR AND GATE SPRING HINGES SHALL BEADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOROR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM.(SECTIONS 11B-404.2.8.1 AND 11B-404.2.8.2).14. THE WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITH A DOOR THATHAS AN AUTOMATIC-CLOSING DEVICE, AND SHALL HAVE A CLEAR,UNOBSTRUCTED OPENING WIDTH OF 34 INCHES.15. THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPEDWITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH. THELATCH SHALL BE FLIP-OVER STYLE, SLIDING OR OTHER HARDWARE NOTREQUIRING THE USER TO GRASP OR TWIST.16. EXCEPTION: IN GROUPS A, DIVISION 3, B, F, M, AND S OCCUPANCIES ANDIN ALL CHURCHES, KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXITWHEN THE MAIN EXIT CONSISTS OF A SINGLE DOOR OR PAIR OF DOORS IFTHERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THEDOOR STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESSHOURS". THE SIGN SHALL BE IN LETTERS NOT LESS THAN 1 INCH ON ACONTRASTING BACKGROUND. WHEN UNLOCKED, THE SINGLE DOOR OR BOTHLEAVES OF A PAIR OF DOORS MUST BE FREE TO SWING WITHOUTOPERATION OF ANY LATCHING DEVICE. THE USE OF THIS EXCEPTION MAYBE REVOKED BY THE BUILDING OFFICIAL [FOR HCD 1&2] ENFORCING AGENCYFOR DUE CAUSE.17. EXIT DOORS SHALL BE FURNISHED & INSTALLED WITH HARDWARE ALLOWINGDOOR TO BE OPENED FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANYSPECIAL KNOWLEDGE OR EFFORT. PAIRS OF EXIT DOORS SHALL BEFURNISHED & INSTALLED WITH APPROVED AUTOMIAC FLUSH BOLTS ON ONEOF THE DOOR LEAVES AND NO SURFACE MOUNTED HARDWARE INSTALLED ONSAME LEAF. THE UNLATCHING OF BOTH DOOR LEAVES SHALL NOT REQUIREMORE THAN ONE OPERATION.RAMPS1. ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE ISGREATER THAN 1 FOOT OF VERTICAL RISE IN 20 FEET OF HORIZONTAL RUN(5% GRADIENT). THE LEAST POSSIBLE SLOPE SHALL BE USED FOR ANY RAMP(SECTION 11B-405.2).2. WIDTH: PRIMARY ENTRANCE AND SPECIAL OCCUPANCY, PEDESTRIAN RAMPSSERVING PRIMARY ENTRANCES TO BUILDINGS HAVING AN OCCUPANT LOADOF 300 OR MORE SHALL HAVE A MINIMUM CLEAR IN WIDTH OF 60 INCHES.RAMPS SERVING GROUP R OCCUPANCIES MAY BE 36 INCHES CLEAR WIDTHWHEN THE OCCUPANT LOAD IS 50 OR LESS. ALL OTHER PEDESTRIAN RAMPSSHALL HAVE A MINIMUM WIDTH OF 48 INCHES (SECTION 11B-405.5).3. SLOPE: THE MAXIMUM SLOPE OF A RAMP THAT SERVES ANY EXIT WAY THATPROVIDES ACCESS FOR PERSONS WITH PHYSICAL DISABILITIES OR IS INTHE PATH OF TRAVEL SHALL BE 1 FOOT OF VERTICAL RISE IN 12 FEET OFHORIZONTAL RUN (8.3% MAX. GRADIENT) (SECTION 11B-405.2). THE CROSSSLOPE OF RAMP SURFACES SHALL BE NO GREATER THAN 1 UNIT VERTICAL IN48 UNITS HORIZONTAL (SECTION 11B-405.3).4. A CURB, 2 INCHES HIGH MINIMUM, OR BARRIER SHALL BE PROVIDED THATPREVENTS THE PASSAGE OF A 4 INCH DIAMETER SPHERE, WHERE ANYPORTION OF THE SPHERE IS WITHIN 4 INCHES OF THE FINISH FLOOR ORGROUND SURFACE. TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIERSHALL PROVIDE A CONTINUOUS AND UNINTERRUPED BARRIER ALONG THELENGTH OF THE RAMP.WALKS AND SIDEWALKS1. CONTINUOUS SURFACE: WALKS AND SIDEWALKS SUBJECT TO THESEREGULATIONS SHALL HAVE A CONTINUOUS COMMON SURFACE, NOTINTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/2INCH AND SHALL BE A MINIMUM OF 48 INCHES IN WIDTH. LEVEL CHANGESGREATER THAT 1/4 INCH AND UP TO 1/2 INCH SHALL BE BEVELED WITH ASLOPE NO GREATER THAN 1:2 (PER SECTION 11B-303.2 AND 11B-303.3).SURFACES SHALL BE SLIP RESISTANT AS FOLLOWS: (SECTION 11B-302.1).A.SLOPES LESS THAN 6 PERCENT: SLIP-RESISTANT AS DESCRIBED FOR AMEDIUM SALTED FINISH.B.SLOPES 6 PERCENT OR GREATER: SHALL BE SLIP-RESISTANT.C.SURFACE CROSS SLOPES: SHALL NOT EXCEED 1:482. GRATINGS: WALKS, SIDEWALKS, AND PEDESTRIAN WAYS SHALL BE FREE OFGRATING WHENEVER POSSIBLE. FOR GRATINGS LOCATED IN THE SURFACEOF ANY OF THESE AREAS, GRID OPENINGS IN GRATINGS SHALL BE LIMITEDTO 1/2" (13 MM) IN THE DIRECTION OF TRAFFIC FLOW (SECTION 11B-302.3).3. CHANGES IN LEVEL: ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLEROUTE SHALL NOT EXCEED 1/2 INCH. WHEN CHANGES IN LEVEL DO OCCUR,THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAT 1 UNIT VERTICALIN 2 UNITS HORIZONTAL. EXCEPT THAT LEVEL CHANGES NOT EXCEEDING 1/4INCH MAY BE VERTICAL. WHEN CHANGES IN LEVELS GREATER THAN 1/2 INCHARE NECESSARY THEY SHALL COMPLY WITH THE REQUIREMENTS FOR CURBRAMPS (SECTION 11B-303.4).No. Description Date By6/8/2021, 1:58:25 PM21-0396LUMEN ARCEO
|