VEEDER- ROOT <br /> DEC 0 8 2022 <br /> v= NVIRONMENTAL HEAL I <br /> Bectronic Pressurized Line Leak Detection <br /> Why Electronic PLLD for Detecting Line Leaks? <br /> The Veeder- Root Electronic Pressurized Line Leak Detection (PLLD) system is designed to meet your everyday compliance needs . Our <br /> patented technology performs precision line leak testing at full pump pressure for 0 . 1 and 0 . 2 gallons per hour (gph) and a pressure <br /> decay test to meet the U . S . EPA 3 . 0 gph test requirements . The Veeder-Root Electronic PLLD system works in a variety of pressurized line <br /> applications, and offers flexible testing and digital reporting options, helping to detect catastrophic leaks . When paired with a TLS-450PLUS <br /> Automatic Tank Gauge (ATG) , customers can monitor up to 1178 gallons of fuel line volume . <br /> i <br /> CVEEM <br /> vo <br /> 16 IF! <br /> If the pressure is out of normal range, the TLS-450PLUS will record a failing result and generate an audible and visual alarm for the store operator <br /> SYSTEM FEATURES <br /> • Pressure sensor is installed without breaking piping or adding a new sump, and is constructed with stainless steel <br /> to meet the challenges of a highly corrosive environment. <br /> • Test lines at full pressure for quick and accurate results, without restricting fuel flow rate . <br /> • Conducts a 3 . 0 gph test, which meets EPA and NFPA 30 release detection requirement for pressurized line systems, <br /> once all dispensing is completed to ensure the integrity of the line. <br /> • Standard 3 . 0 gph and optional 0. 1 and 0 . 2 gph tests can be manually performed to reset alarms . <br /> • Monitors line pressure during dispensing activity to ensure a catastrophic leak is not occurring during a dispense . <br /> If a leak is detected at a pre-set pressure threshold, the system will shutoff power to the Submersible Turbine Pump <br /> (STP) to minimize environmental damage and prevent a public safety issue . <br /> • Built- in calibration verification to notify the site operator when the pressure transducer is not operating properly. <br /> • Auto=Confirm function, when enabled, runs a second line leak test, if an initial test failure occurs, to verify and reduce <br /> false alarms due to mechanical issues that may be occurring in other parts of the fueling system . <br /> • Provides two alarm shutdown options when failure occurs: Standard Dispenser Shutdown (Alarm and Shutdown ) <br /> and Optional No Shutdown (Alarm Only) . <br /> • Not impacted by thermal contraction of fuel in the line due to changes in temperature . <br />