6. If high piled combustible storage is to be used in a building, an automatic fire sprinkler system <br /> will be required. <br /> 7. Accessible routes shall be provided per CBC § 11 B-206. At least 1 accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones; public streets and sidewalks; and public transportation stops to the accessible building <br /> or facility entrance they serve. Where more than one route is provided, all routes must be <br /> accessible. §11 B-206.2.4 <br /> 8. At least 1 accessible route shall connect accessible buildings, accessible facilities, accessible <br /> elements and accessible spaces that are on the same site. §11 B-206.2.2 <br /> 9. At least 1 accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility, including mezzanines,which are <br /> otherwise connected by a circulation path. §11 B-206.2.4 <br /> 10. Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are required <br /> for each phase of the project. These parking space(s) shall be located as close as possible to <br /> the primary entrance to the building. <br /> 11. Adequate sanitary facilities shall be provided for the facility, per the requirements of Chapter 4 <br /> of the California Plumbing Code. <br /> 12. Pursuant to Section 422.4 of the California Plumbing Code, toilet facilities shall be accessible <br /> to employees at all ties, should not be more than 500 feet from where employees are regularly <br /> employed, and accessible by not more than 1 flight of stairs. The plans shall indicate the <br /> location of the toilet facilities and the travel distance from work areas. <br /> 13. This project will be required to comply with the Model Water Efficiency Landscape Ordinance <br /> requirements of the California Code of regulations, Title 22, Division 2, Chapter 2.7 <br /> 2. DEPARTMENT OF PUBLIC WORKS (Contact: [209]468-3000) <br /> a. An encroachment permit shall be required for all work within road right-of-way. (Note: Driveway <br /> encroachment permits are for flatwork only—all vertical features, including but not limited to fences, <br /> walls, private light standards, rocks, landscaping and cobbles are not allowed in the right-of-way.) <br /> (Development Title Sections 9-1145.4 and 9-1145.5) <br /> b. Prior to issuance of the occupancy permit, the driveway approach shall be improved in accordance <br /> with the requirements of San Joaquin County Improvement Standards Drawing No. R-13. <br /> (Development Title Section 9-1145.5) <br /> c. Upon approval of the Wilcox Road Specific Plan Amendment, the following improvements shall be <br /> made: <br /> 1. A turnaround for trucks shall be provided at the terminus of Wilcox Road at the south end of <br /> the property. <br /> d. The Water Supply Facilities Impact Mitigation Fee shall be required for this development. The fee <br /> is due and payable prior to issuance of the building permit. The fee will be based on the current <br /> schedule at the time of payment. (Development Title Section 9-818.4 and Resolutions R-91-327, <br /> R-94-185 and R-97-5) <br /> e. The Traffic Impact Mitigation Fee shall be required for this application. The fee is due and payable <br /> at the time of building permit application. The fee shall be automatically adjusted July 1 of each <br /> PA-1900286—Conditions of Approval 4 <br />