ARCHIVED REPORTS_2019 SOIL MGMT PLAN (JULY-REVISED)
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
500
>
4400 - Solid Waste Program
>
PR0504201
>
ARCHIVED REPORTS_2019 SOIL MGMT PLAN (JULY-REVISED)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 3:16:25 PM
Creation date
5/23/2022 2:52:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2019 SOIL MGMT PLAN (JULY-REVISED)
RECORD_ID
PR0504201
PE
4430
FACILITY_ID
FA0000214
FACILITY_NAME
PILKINGTON NORTH AMERICA INC PLANT 10
STREET_NUMBER
500
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330-9739
CURRENT_STATUS
01
SITE_LOCATION
500 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1528
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Murphy Parkway Warehouse <br />December 19, 2016 <br />Job No. 146-618 <br />Page 7 <br />Foundations for trash enclosure walls, signs, landscape retaining walls, and other appurtenant <br />construction should extend a minimum of 12 inches below the building pad or lowest surrounding soil <br />grade, and have a minimum width of 12 inches. Such foundations may be sized for allowable soil <br />bearing pressures of 1500 psf for dead load, 2300 psf for dead plus live load, and 3000 psf for dead plus <br />live plus seismic/wind loads. <br /> <br />The weight of foundation concrete below grade may be disregarded in sizing computations. Continuous <br />foundations should be reinforced with at least four No. 4 bars--two each, top and bottom, as a minimum. <br />The actual reinforcement should be determined by the Structural Engineer. <br />Foundation excavations should not be allowed to stand open for extended periods prior to concrete <br />placement and should be clean and free of all loose and/or soft materials when concrete is placed. The <br />bearing materials should be in a firm, moist condition. Some dock foundation excavations may engage <br />clean or saturated sands and experience sloughing and caving; forming may be required. <br />Resistance to lateral forces may be computed using either friction or passive pressure, but not both, <br />except as recommended below. A coefficient of friction of 0.30 may be utilized for design. Passive <br />earth pressure may be considered equivalent to a fluid weighing 250 pounds per cubic foot. A <br />combination of both friction and passive pressure may be utilized provided the larger mode of resistance <br />is reduced by 50 percent. The recommended passive pressure and friction coefficient values have been <br />modified by appropriate factors of safety and may be applied directly in design calculations. <br />SEISMIC DESIGN <br />In design using the lateral force provisions of the 2013 and 2016 California Building Codes, the <br />parameters in Table 1 may be used. <br />TABLE 1 <br />Period <br />(seconds) <br />Mapped <br />Spectral <br />Response <br />Accelerations <br />(g) <br />Site <br />Class <br />Site <br />Coefficients <br />Maximum <br />Considered <br />Earthquake <br />Spectral <br />Response <br />Accelerations <br />(g) <br />Design <br />Spectral <br />Response <br />Accelerations <br />(g) <br />0.2 SS 1.065 <br />D <br />Fa 1.074 SMS 1.144 SDS 0.762 <br />1 Sl 0.372 Fv 1.655 SMl 0.616 SDl 0.411 <br />LOADING DOCK WALLS <br />Restrained dock walls should be capable of resisting an at-rest soil pressure equivalent to that exerted <br />by a fluid weighing 50 pounds per cubic foot. Wall design also should consider pressures associated <br />with traffic or other adjacent surcharge. Care should be taken to avoid exertion of excessive compaction