S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> STOCKTON FOOD AND GAS 1605 S EL DORADO ST, STOCKTON July 21, 2022 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST. <br /> OBSERVATION: UST Tank Information forms are not current in the California Environmental Reporting System <br /> (CERS). <br /> -The 91 tank form incorrectly states that the riser is fiberglass. <br /> -The 87 tank form stated that the vapor recovery piping is steel.Vapor recovery piping was observed to be <br /> fiberglass. <br /> -The 87 tank form states that the vent transition sump is single walled. No vent transition sump was observed on <br /> site. <br /> REGULATION GUIDANCE:Any change of information must be updated in CERS within 30 days of the changes. <br /> CORRECTIVE ACTION: Immediately log into CERS, update the required information, and submit for review by the <br /> EHD. <br /> This is a repeat violation, Class Il. <br /> 104 CCR 2632(d)(1), 2634(d)Failure to submit a complete and accurate UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br /> -Both monitoring plans list the UDC leak sensor as being a Veeder Root 205. Floats and chains were observed on <br /> site. <br /> -Both monitoring plans list the UCD as being plastic.A steel UDC was observed on site. <br /> -Both monitoring plans incorrectly state that'Detection of a Leak in the UDC triggers and Audible Visual Alarm',that <br /> the'UDC Alarm Triggers a Automatic Pump Shutdown'&that'Fail u re/Discon nection of the UDC Monitoring System <br /> triggers Automatic Pump Shutdown'. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a repeat violation, Class II. <br /> FA0006185 PR0504388 SC333 07/21/2022 <br /> EHD 23-01 Rev.9/16/2020 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />