Laserfiche WebLink
S A N J O A Q U I N Environmental Health Department <br /> C.C_3 U N I Y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> STOCKTON FOOD AND GAS 1605 S EL DORADO ST, STOCKTON July 21, 2022 <br /> File Review <br /> 121 HSC 25299(a)(8), False statements,representation,or certification made on an application,record,or other document ❑V ❑R ❑COS <br /> 25299(b)(7) <br /> 122 CCR 2712(f) Failure to implement corrections and submit written response within 30 days of receiving the report ❑V ❑R ❑COS <br /> On Site Records <br /> 201 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance ❑V ❑R ❑COS <br /> 202 CCR 2712(i) Failure to retain a paper or electronic copy of the permit to operate at the facility ❑V ❑R ❑COS <br /> 203 CCR 2712(b)(1-2) Failure to maintain monitoring records for 36 months and maintenance records for 60 months ❑V ❑R ❑COS <br /> 204 CCR 2712(b)(6) Failure to maintain records of repairs,lining,and upgrades on site,for the life of the UST ❑V ❑R ❑COS <br /> 205 CCR 2712(i) Failure to submit and have current UST Monitoring Plan readily accessible at the facility ❑V ❑R ❑COS <br /> 206 CCR 2712(1),2634(e) Failure to submit and have a current UST Response Plan readily available on site ❑V ❑R ❑COS <br /> 207 CCR 2716(f) Failure to maintain designated operator inspection reports and all attachments on site for 36 months ❑V ❑R ❑COS <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements ❑V ❑R ❑COS <br /> 209 CCR 2715(c)(3), Failure to maintain a copy of the"Facility Employee Training Certificate"on-site ❑V ❑R ❑COS <br /> 2715(c)(4) <br /> 210 CCR 2715(c) Failure to provide initial training,train every 12 months,and have a trained employee present ❑V ❑R ❑COS <br /> 211 CCR 2715(c)(2) Failure to have or implement a training program approved by the UPA,at an unstaffed facility ❑V ❑R ❑COS <br /> 212 CCR 2651;HSC 25294 Failure to record any unauthorized release from primary containment ❑V ❑R ❑COS <br /> 213 CCR 2650(e),2652 Failure to notify and submit report of reportable unauthorized release or record release ❑V ❑R ❑COS <br /> 214 CCR 2712 Failure to comply with UST operating permit conditions ❑V ❑R ❑COS <br /> 215 CCR 2715 Designated operator,service tech,or installer did not possess current certifications ❑V ❑R ❑COS <br /> 216 HSC 25281.5(b)(2) Failure to meet exclusion requirements for unburied fuel piping at a marina ❑V ❑R ❑COS <br /> 217 HSC 25281.5(b)(3) Failure to meet exemption requirements for emergency generator unburied fuel piping ❑V ❑R ❑COS <br /> us System Observations <br /> 301 HSC 25292.1(a) Failure to operate UST system to prevent unauthorized releases including leaks,spills and overfills ❑V ❑R ❑COS <br /> 302 CCR 2630(d),2641(a) Leak detection equipment not installed/maintained/located to detect leaks at earliest opportunity ❑V ❑R ❑COS <br /> 303 CCR 2630(d),2641(a) Failure to maintain piping to allow liquid to flow into sump(i.e.failure to remove test boots) ❑V ❑R ❑COS <br /> 304 CCR 2631(a);HSC Failure to construct,operate,and maintain primary containment as product-tight ❑V ❑R ❑COS <br /> 25290.1(c) <br /> 305 HSC 25290.1,25290.2, Failed to maintain secondary containment(e.g.failure of secondary containment testing) ❑V ❑R ❑COS <br /> 25291 <br /> 306 HSC 25291(e) Failure to remove,analyze,and properly dispose of water in secondary containment(pre-Jul 2003) ❑V ❑R ❑COS <br /> 307 HSC 25290.1(c3), Failure to keep water out of the secondary containment system(post-Jul 2003) ❑V ❑R ❑COS <br /> 25290.2(c3) <br /> 308 CCR 2632(c),2634(d), Failure of the leak detection equipment to have an audible and visual alarm ■V ■R ■COS <br /> 2636(f) <br /> 309 CCR 2666(b)(2), Failure to have continuous monitoring that activates audible-visual alarm or stops flow at dispenser ❑V ❑R ❑COS <br /> 2636(f)(1) <br /> 310 CCR 2636(f)(4) Failure to meet monitoring requirements in lieu of being tightness tested every 12 months ❑V ❑R ❑COS <br /> FA0006185 PRO504388 SC333 07/21/2022 <br /> EHD 23-01 Rev.9/16/2020 Page 2 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />