My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 9:33:30 AM
Creation date
5/31/2022 1:10:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0518288
PE
2351
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ U A Q U I N Environmental Health Department <br /> C.0UNTY <br /> I. MONITORING: All monitoring equipment must be listed in the State Water Resources Control Board <br /> Division of Clean Water Program Local Guidance Letter 113, <br /> Check Code <br /> Box section <br /> 23 ccR <br /> All secondary containment units (e.g. tank annular spaces, secondary piping, sumps, <br /> 2632 under-dispenser containment, etc.) monitored for leaks using approved electronic leak <br /> 2635(f) detections stems. <br /> Electronic monitoring sensors located at the following points: <br /> ° At the bottom of the interstitial space of each secondarily-contained tank, <br /> positioned as near as possible to the bottom of the tank. <br /> Manufacturer VEEDER-ROOT Model 794380-303 <br /> ° In each collection sump, positioned as near as possible to the bottom of the <br /> collection sump. Additionally, in any sump acting as secondary containment for <br /> unused tank openings which connect to the primary space. <br /> Manufacturer VEEDER-ROOT Model 794380-323 <br /> 23 2632CR <br /> 2630(d) ° In dispenser pans which do not drain into secondary containment piping. (Note: <br /> A mechanical switch which triggers a shear valve may be substituted but this <br /> system will not qualify for the annual line tightness test exemption under 23 CCR <br /> ,2636(g)). <br /> Manufacturer VEEDER-ROOT Model 794380-323 <br /> F-Along secondarily-contained pipe runs which do not meet the 118 inch-per-foot <br /> slope requirement, positioned in the depressed or low-lying areas. <br /> Manufacturer N/A Model <br /> 23 CCR Automatic line leak detectors installed to monitor underground pressurized piping, <br /> 2636{f} <br /> V NSC Manufacturer VEEDER-ROOT Model 88480-001 <br /> 25290.1 h <br /> 25290.2 <br /> Alarm panel provides both audible and visual alarms. It is located in a protected area <br /> 23 CCR and within sight and hearing distance of on-site personnel and hard-wired to a <br /> 2632(c)(2)(B) dedicated circuit. <br /> �f <br /> Manufacturer VEEDER-ROOT Model TLS-35OR <br /> J. OTHER COMPONENT INFORMATION: <br /> COMPONENT MANUFACTURER MODEL COMPOSITION <br /> CONTAINMENT DW PTS (OWT)5418 DOUBLE WALL FRP <br /> SUMP SOLUTIONS <br /> UNDER-DISPENSER S. BRAVO SYSTEMS 8253-F2L-BD-AB-EO DOUBLE WALL FRP <br /> CONTAINMENT <br /> PENETRATIONS S. BRAVO SYSTEMSF-125-PE-D FRP <br /> a of 8. <br />
The URL can be used to link to this page
Your browser does not support the video tag.