Laserfiche WebLink
1 1 1 1/L-Product Data <br /> Typical Pipe Performance <br /> Nominal Pipe Size Pressure Rating(') Ultimate Internal Pressure(') Ultimate Collapse Pressure(') <br /> in mm psig MPa psig MPa psig MPa <br /> 2 50 200 2.07 3200 22.1 153 1.05 <br /> 3 80 200 1.38 2400 16.5 90 0.62 <br /> 4 100 175 1.21 2000 13.8 39 0.27 <br /> 6 150 175 1.21 2000 13.8 38 0.26 <br /> M At 80-F(27-C). <br /> (2)At 80-F(27°C).For continuous service do not exceed 75%oft hese valu es. <br /> Typical Mechanical Properties <br /> Pipe Property('( Method <br /> Tensile Strength <br /> Longitudinal 35,000 psi 1241.3 MPa ASTM D2105 <br /> Circumferential 70,000 psi 1482.7 MPa ASTM D1599 <br /> Poisson's Ratio v,,(')-V,(3) 0.16-0.26 FGSTM <br /> Tensile Modulus <br /> Longitudinal 25,000 psi 172.4 Mpa ASTM D2105 <br /> Circumferential 38,000 psi 262.0 MPa FGSTM <br /> Compressive Strength <br /> Longitudinal 24,500 psi 1 168.9 MPa FGSTM <br /> Compressive Modulus <br /> Longitudinal 26,000 psi 1179.3 MPa FGSTM <br /> Cyclic 8,000 psi 155.2 MPa I ASTM D2992 Procedure <br /> Typical Physical Properties Pipe Length <br /> Pipe Property Value Value Method Size Standard Random <br /> in mm ft m ft m <br /> Thermal 1.7BTU-in/heft'-°F 7.6 W/m'C ASTM C177 <br /> Conductivity 2-6 50-150 20 6.1 17-21 5.2-6.4 <br /> Thermal 8.5x10-bin/in°F 15.3x10-bcm/cm'C ASTM D696 <br /> Expansion Minimum Bending Radius <br /> Friction Factor Hazen-Williams 150.0 <br /> Size Minimum Bending Radius(') <br /> Absolute 0.00021 in 0.00053 mm <br /> Roughness in mm ft m <br /> Specific Gravity 1.8 ASTM D792 2 50 75 23 <br /> Barcol Hardness 65.0(Impressor 934-1) ASTM D2583 3 80 100 38 <br /> 4 100 150 46 <br /> M Based on structural wall thickness. 6 150 1 200 61 <br /> "'Vn,=The ratio of axial strain to hoop strain resulting from stress in the hoop direction. MAt rated pressure.Sharper bends may create excessive stress concentrations.Do not bend <br /> (3)Van=The ratio of hoop strain to axial strain resulting from stress in the axial direction. pipe until adhesive has cured. <br /> National Oilwell Varco has produced this brochure for general Fiber Glass Systems <br /> information only,and it is not intended for design purposes. 17115 San Pedro Avenue,Ste 200 <br /> Although every effort has been made to maintain the accuracy and <br /> reliability of its contents,National Oilwell Varco in no way assumes San Antonio,Texas 78232 USA <br /> responsibility for liability for any loss,damage or injury resulting Phone:210 477 7500 <br /> from the use of information and data herein nor is anywarranty Fax:210 477 7560 <br /> expressed or implied.Always cross-reference the bulletin date <br /> with the most current version listed at the web site noted in this <br /> literature. <br /> ©2016 National Oilwell Varco All rights reserved <br /> FH3500ENG August 2016 <br /> Fiber Glass Systems I KOYCornplProduction Solutions fgspipe@nov.com nov.com/fgs <br />