My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 9:33:30 AM
Creation date
5/31/2022 1:10:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0518288
PE
2351
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br /> H00 <br /> Cn W <br /> J 0 0 <br /> SHORE TANK EXCAVATION PER OSHA REQUIREMENTS AND TANK MANUFACTURE Q <br /> INSTALLATION INSTRUCTIONS. REFER TO PROJECT SOILS REPORT AND CIVIL 0 0 <br /> DRAWINGS FOR ANY ADDITIONAL RECOMMENDATIONS. ALL SHORING IF REQUIRED o W J <br /> TO BE ENGINEERED AND PERMITTED UNDER SEPARATE PERMIT BY CONTRACTOR. Q WCOU <br /> REFER TO ARTICLE 13200B OF PROJECT MANUAL. N <br /> z Z J Z 0) LLL <br /> Q Q J <br /> B ~ cj � az_ <br /> 18 WIDE X 2" TALL c O Z Q U J <br /> SEE CIVIL SHEETS FOR TV CONCRETE CROWN REINFORCED CONCRETE SLAB mz - <br /> o 0 <br /> ADJOINING CONDITIONS MIN. (TYP.) SEE STRUCTURAL DRAWING 0 co <br /> 0 Z <br /> FOR SPECIFICATIONS V' N 0 Q <br /> 8 <br /> C) Q o cr <br /> a Of = Q <br /> a_ U a_Q0z - -� � U1 O 0 <br /> � Qw cn � � aW CA <br /> w o INSTALL FILTER FABRIC a Q Q CV <br /> C) 03 <br /> o BACKFILL AT TANK HOLE (TYP.) o o >o Y z J � <br /> EXTEND CONTINUOUS FILTER 0 <br /> COMPACTED FABRIC TO SLAB m m m m W U <br /> SOIL * ALL GASOLINE m <br /> TANK TOPS TO <br /> co BE SET LEVEL LL <br /> N o <br /> 3'-9" 71'-4"01 <br /> o <br /> z <br /> REINFORCED CONCRETE SLAB ABOVE SEE —\ _FOURTH LIFT OF <br /> 5'—g" CONSOLIDATED BACKFILL, <br /> CIVIL DRAWING FOR SPECIFICATIONS <br /> Q FILL TO TOP OF TANK <br /> 40,000 GALLON DOUBLE WALL <br /> x FIBERGLASS TANK <br /> i � 2'-0" UL 1316 LISTED AND 2'-O" <br /> OUTLINE OF CONCRETE CROWN a- METHANOL COMPATIBLE. <br /> 18" MIN. (TYP.) O Q 10'—6" 0.D. <br /> O ° 2'-9"—THIRD LIFT OF CONSOLIDATED BACKFILL, <br /> 0 3/4" DEEP WATERTIGHT (-F ° ° 1 ° TAMP BACKFILL BENEATH TANK <br /> R39%1 <br /> MANHOLE/LID ASSEMBLY FOR TURBINE ID TAG RECESSE ° <br /> 12 FLUSH WITH 'r3_3 ° ° SECOND LIFT OF CONSOLIDATED <br /> AND FILL SUMP ENTRY (TYP.) CONCRETE ° �° l '-O"—BACKFILL, TAMP BACKFILL BENEATH TANK <br /> PREMIUM UNL. 91 OCTANE <br /> OBSERVATION <br /> 40,000 GALLON PORT (TYP.) ° ° ° ° ° ° FIRST LIFT OF CONSOLIDATED BACKFILL, <br /> 1111 TANK 5 o'p 1 —Q <br /> , ,, ,; ,,, ° - ° ° ° ° ° ° ° TAMP BACKFILL BENEATH TANK <br /> 25" MANWAY ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ** 1 '-0" BED OF CONSOLIDATED BACKFILL, TAMP _ <br /> „ 25" MANWAY / / / / / / / / / / / / / / / / / BACKFILL BENEATH TANK <br /> 24" MAN H OLE 34 16 DJ �I <br /> ACCESS TO ANNULAR <br /> MONITOR CONC. DEADMEN UNDISTURBED Q W O <br /> 18"x8" (TYP. OF 2) ��-�2INSTALL FILTER FABRIC AT <br /> A BOTTOM OF TANK HOLE (TYP.) SOIL W Fr J Fr0) <br /> 0 T5-Z NOTE. <br /> NOTE: FOLLOW UST MANUFACTURERS COMPLETE CURRENT GROUNDWATER IS ENCOUNTERED DURING O 0 <br /> N ' EXCAVATION FOR TANK INSTALLATION OR IF = W <br /> INSTALLATION INSTRUCTIONS. OSHA TYPE "C" SIMPLE SLOPE POTENTIAL EXISTS FOR SURFACE RUN-OFF _ <br /> INTO TANK PIT, CONTRACTOR SHALL STRAP Q <br /> SHOWN IN THIS VIEW THE TANKS TO THE DEADMEN AND BACK FILL O J � <br /> TO TOP OF TANKS IMMEDIATELY AFTER TANK 0 0) 0 <br /> � Tank Burial (Shored Hole Method) PLACEMENT, THEN CONTRACTOR SHALL � O Q <br /> C ENTIRELY FILL TANKS WITH WATER. THE ABOVE, O (n <br /> T3-1 SCALE: 3/8"=1 '-0" (TANK BALLAST & PLACEMENT BY FILLING WITH U <br /> WATER) SHALL BE DONE IN ONE CONTINUOUS <br /> NOTE: PROCESS. TANKS SHALL BE PUMPED DRY <br /> FILTER FABRIC (US FABRICS US200 OR DUPONT SF 40) IS REQUIRED AT BOTTOM AND ONLY AFTER FINAL BACK FILL AND CONCRETE <br /> COVER IS IN PLACE. ** FOR WET-HOLE <br /> SIDES OF TANK HOLE EXCAVATIONS, FOR ALL INSTALLATIONS. FABRIC MAY BE PINNED INSTALLATION THE TANK BACKFILL BEDDING <br /> TO SIDE OF HOLE WITH WIRE, ETC. SEAMS MUST BE LAPPED 1 ' MINIMUM. SHALL BE INCREASED FROM 12" TO 18". SEE O <br /> NOTE: MANUFACTURER INSTALLATION INSTRUCTIONS LL <br /> DEADMEN ARE TO BE PRE CAST ABOVE GROUND AND LOWERED INTO EXCAVATION. FOR ADDITIONAL CLARIFICATION. <br /> BACKFILL MEDIA SHALL CONSIST OF CLEAN NATURALLY-ROUNDED AGGREGATE WITH PARTICLE SIZES <br /> NO LARGER THAN 3/4" WITH NO MORE THAN 5% PASSING A #8 SIEVE OR WASHED CRUSHED <br /> 0 STONE OR GRAVEL, WITH ANGULAR PARTICLE SIZES NO LARGER THAN 1/" WITH NO MORE THAN 5% <br /> TANK(S): PASSING A #8 SIEVE. REFER TO TANK MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR <br /> A New Tank Field Layout Plan SHALL BE UNDERWRITERS LABORATORY LISTED (UL-1316) AS CALLED FOR ON THE SITE SPECIFIC DRAWING OR AS DESIGNATED ON THE SUPPLEMENTAL CONDITIONS AND ADDITIONAL INFORMATION. SIEVE ANALYSIS OF BACKFILL IS REQUIRED. SUBMIT TO ARCHITECT & <br /> SHALL BE DOUBLE WALL TANKS OF FIBERGLASS REINFORCED PLASTIC (FRP) AS MANUFACTURED BY "CONTAINMENT SOLUTIONS". INSTALLATION OF TANKS AND PIPING T3 PROVIDE TO FACILITY INSTALLATION OVERSIGHT AGENT AT TANK SET.-1 SCALE: 1/4"-1 '-0" SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE INSTALLATION SPECIFICATION AS PROVIDED BY COSTCO WHOLESALE, AND MANUFACTURER'S INSTRUCTIONS. <br /> NOTE: ACTUAL BENCH AND SLOPE CONDITIONS TO BE EVALUATED BY CONTRACTOR'S COMPETENT PERSON IN ACCORDANCE WITH ALL <br /> APPLICABLE SAFETY ORDINANCES AND CODES. WHERE BENCH IS NOT CONSTRUCTED AS SHOWN DUE TO UNSTABLE SOIL CONDITIONS OR <br /> 5 <br /> TANK <br /> ONLY TURBINE END SAFETY CONSIDERATIONS, SIDEWALL CLEARANCE TO THE TANKS MUST BE INCREASED FROM 2'-0" TO 5'-0" PER MANUFACTURER'S rD AINSTALLATION INSTRUCTIONS. 18 ' FILL END TA TANK #5 ONLY o QRpFESSioHq�� <br /> rc 2" HIGH CROWN TYP. AROUND REINFORCED CONCRETE SLAB <br /> T4-1 ALL OPENINGS (SEE NOTE2) SEE CIVIL DRAWINGS 4 DIA. 40 PVFRIP OCR RISER SCH35 �= HAL P. GRUBBrm <br /> a <br /> 1 4 11 <br /> ad a. _ <br /> ° a <br /> ------BRINE HYDROSTATIC RESERVOIR TO TLS-350R RINE HYDROSTATIC RESERVOIR �qTF / v 1 <br /> MONITORING SYSTEM of CAF <br /> o I 54" CONTAINMENT - 5'-0" MIN. TO HYDROSTATIC 36 54" CONTAINMENT COLLAR W/ A 05/27/22 <br /> COLLAR W/ A 25 �0 MAX. TOTAL BURY SENSOR 25 FLGD. MANWAY w/2 (4 ) NPT x <br /> X <br /> FLGD. MANWAY w/5 �, BRINE HYDROSTATIC FTGS. AND 2 (2") NPT FTGS. ;; Q Q <br /> c z 0) z o <br /> m (4") NPT FTGS. � 33 33 RESERVOIR � � � � � � <br /> _ > m <br /> O O N II <br /> m <br /> NOTE: <br /> cn <br /> 1 . THE TANK FILL END SHALL BE Q m <br /> IN-TANK GAUGE PROBE W/90� INSTALLED ONE INCH LOWER IN co <br /> 51 o 48 47 OVERFILL ALARM CALIBRATION. INSTALL ELEVATION THAN THE TANK TURBINEEND. <br /> PER MFR'S REQMNT'S. DROP TUBE W/ OVERFILL 2' V O o <br /> 1 15 PREVENTION VALVE SET CLR. v N <br /> I CD FE-PETRO 2. CONTRACTOR SHALL VERIFY EXACT <br /> CD 24"x1 /4" THICK STRIKER 38 SUBMERSIBLE PUMP @ 95� CAPACITY. TYP. STRAP SPACING WITH TANK d <br /> PLATE UNDER ALL 40,000 GALLON DOUBLE WALL TERMINATE DROP TUBE bJ �- <br /> II II II II II II II II CONTAINMENT SOLUTIONS MANUFACTURER PRIOR TO HOLD DOWN <br /> OPENINGS BY TANK FE-PETRO INTAKE MIN. 4 , MAX. 6 ABOVE CONSTRUCTION. +� m E <br /> UNDERGROUND FIBERGLASS STRIKER PLATE .� o <br /> MANUFACTURER TYP.) 40 FILTER SCREEN L <br /> ( STORAGE TANK 4" TO 6" MAX. 0 <br /> TANK BOTTOM 3. BACKFILL TO MEET CLEAN FILL <br /> (SEE CRITICAL DIM NOTE) 45 184 a� <br /> " PROTECTOR REQUIREMENTS PER RMC 15.24.095. W7� <br /> :3 <br /> N <br /> 1 2 5 6 7 8 9 L 10 11 12 13 14 15 16 L 17 18 19 20 21 22 23 L 24 25 26 27 28 29 30 L 31 32 33 37 38 39 4. GEOMEMBRANE TO BE INSTALLED PER > Mo , <br /> MANUFACTURERS RECOMMENDATIONS <br /> 000N <br /> N I- AND BY CERTIFIED INSTALLER. <br /> CD <br /> Ln <br /> Ln 4- N o <br /> 10" 10 <br /> 10" " 10" cn <br /> » > O N N N <br /> 1 -8 1 -8 1 -8 , 1 -8 16-1/2 m V 00 Y <br /> TYP. i <br /> 0 <br /> 5'-6 1 / 4" 6'-10 1 /2" 7'-2" 6'-10 1 /2" 7'-2" 48 1 /2" 7'-2" 6'-10 1 /2" 5'-9 1 /2" 8'-3" 5'-6 1/4" 0 <br /> Q <br /> X <br /> 01 <br /> 71 '-4" w <br /> ► 1 INDICATES STRAP PLACEMENT ED INDICATES HOLD DOWN STRAP CLIP INDICATES LIFTING LUG LOCATIONCD <br /> N <br /> � INDICATES LIFTING LUG LOCATION <br /> NOTE: U <br /> THE TANK FILL END SHALL BE INSTALLED DROP TUBE CRITICAL DIMENSION: <br /> ONE INCH LOWER IN ELEVATION THAN THE 4" TO 6" MAX. (FROM TOP OF CUT TO TANK BOTTOM) THIS DIMENSION IS CRITICAL AND NOTE CONTRACTOR SHALL VERIFY EXACT <br /> MUST BE ADHERED T0. CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR STRAP SPACING WITH TANK MANUFACTURER o <br /> TANK TURBINE END. PRIOR TO HOLD DOWN CONSTRUCTION. <br /> WILL BE BACK CHARGED FOR EXPENSE TO CORRECT INCONSISTENCIES. o <br /> 0 <br /> a LO r o <br /> B Gasoline 40,000 Gallon Tank Section z o (D O CDNCD <br /> T3-1 SCALE: 3/8"=V-0" <br /> -0" T <br />
The URL can be used to link to this page
Your browser does not support the video tag.