5 76 4" BONDED FITTING <br /> 9 4" COAXIAL "UPP" REMOTE FILL VAPOR PIPING (TYP.) 139 _\ <br /> 31 SUMP SENSOR (SEE NOTE #3) <br /> 5x4 TEST REDUCER FITTING 136 204 3" EZ—F X FEMALE GLUE PIPE FOR FIBERGLASS PIPING <br /> 00 <br /> " <br /> (TYP.) �' 125 1 16 4OVER 3" FRP VAPOR LoJ <br /> RECOVERY PIPING (TYP.) Q 0 =& <br /> PRIMARY COUPLING (TYP.) 141 _ �i 75 4" BONDED FITTING (TYP.) Q <br /> i CA <br /> 4 MALE TERMINATION 138 i�/ o Q I� J <br /> FITTING (TYP.) (� <br /> LLJ m Z Z � Q <br /> 3"x18" FLEXIBLE CONNECTOR W/ EZ—FIT 44 i� 27 4"x4"x3" EXTRACTOR z _ J 0) LL <br /> MALE X EZ—FIT FLANGE (SEE NOTE #10) / o _ TEE FITTING 0 <br /> J <br /> Q Q W <br /> 2" EZ—FIT X MALE HEX ADAPTER (TYP.) 203 °� \° \� — J Z Z <br /> g7 SUMP FLAME ARRESTOR � V <br /> 0 o J Q J <br /> LLJ <br /> 3" EZ—FIT CLAMP W/ 200 j' o o \ 54" DOUBLE WALL o Z <br /> 12 o A N N <br /> Q af >— O <br /> VITON SEAL (TYP.) 4 POLYSIDED FIBERGLASS Q Q Q <br /> O . o ¢ o <br /> 3" EZ—FIT 90 DEGREE ® o CONTAINMENT SUMP O � Z (� <br /> ELBOW TYP. 201 o o W <br /> C� o O <br /> (TYP.) o o /ARU <br /> B o o V) cn � a z � <br /> T5-1 � o T5-1 � � � Q z � co ~ <br /> AT 87 OCTANE TANK #2 ONLY r� o 0 o Y Q O V <br /> 3" BONDED FITTING (TYP.) 73 � <br /> m m m m z <br /> � <br /> 3" OVER 2" SUMP CROSSOVER FRP 110 72 3" BONDED FITTING <br /> (TYP.) <br /> _ <br /> N <br /> PIPING W/ GROMMETED END CAP TO � o <br /> CONTAIN VACUUM TUBING ONLY (TYP.) 116 <br /> 1 " FRP BONDED CONDUIT G ADDITIVE PIPE Z <br /> PENETRATION FITTING (TYP.) 71 T5-1 CONNECTION <br /> 3/4" X 15" FLEXIBLE CONNECTOR 45 4" COAXIAL "UPP" REMOTE FILL <br /> 139 PRODUCT PIPING (TYP.) <br /> A Fill Sump and Hydrostatic Reservoir Plan View (Gasoline Tanks)_ ('C_ <br /> NOT USED E NOT USED <br /> T5-1 SCALE: 1 "=l '—O" <br /> T5-2 SCALE: NONET5-2 SCALE: NONE <br /> MAINTAIN 5" MIN. 6" MAX. CLEARANCE <br /> BETWEEN TOP OF CAP AND GRADE. 37 ACCESS MANHOLE <br /> (SEE NOTE #4) 18„ 10" ABSOLUTE MIN. <br /> 4" PRODUCT I.D. TAG. DISTANCE TO TOP EDGE <br /> RECESSED FLUSH W/ CONC. 12 MIN. TYP. OF SUMP NECK 2J N <br /> (TYP.) 2" CROWN SEE Q W O <br /> NOTE 6 CA ] CO <br /> a o a z <br /> 00 <br /> O0Q <br /> a ° <br /> a <br /> A all. <br /> 2 W <br /> BRINE SUMP RESERVOIR �[ 3f& HYDROSTATIC SENSORA8O <br /> MANOMETER & HDPE TUBING TO TEST N O J Q <br /> ^ Q MONITOR CAP & TRAP PORT FOR CONTINUITY TESTING O U <br /> � FIELD—CUT (LENGTH AS NEEDED) <br /> DOOR PER CARB VR-102 O O <br /> L <br /> � O <br /> _C140 4" FACE SEAL ADAPTER NIPPLE (BY G.C.) O <br /> co <br /> (2) 1 " & (2) 4" GND CLAMPS COUPLER (BY G.C.) O co <br /> Q W/ #6 BARE SOLID V <br /> 63 SUMP FLAME ARRESTOR (TYP.) <br /> 54" DW DIA. SUMP 4 <br /> 00 <br /> o, 64 <br /> EXPLOSION PROOF ELECTRICAL MOUNT FOOT—STEP TO RISER <br /> o <br /> (�� <br /> SEAL—OFF, 6 ABOVE HIGHEST L <br /> ®®®®®®®® ®®® 4" S.S. IRON RISERS (SEE NOTE #9) O <br /> ®®®®®®®®®®®® <br /> PENETRATION (TYP. SEE NOTE #7) <br /> ®® ®®®®® CONTRACTOR SUPPLIED UNISTRUT & <br /> MOUNT FOOT—STEP TO 64 CLAMPS FOR CONDUIT SUPPORT. <br /> RISER (TYP. 2) ATTACH TO RISER WITH U—BOLT <br /> VACUUM TUBING ROUTED — o CLAMP. (TYP. @ ALL CONDUITS) <br /> TO DEVICES MONITORED — 0 4" COAXIAL "UPP" REMOTE FILL <br /> 134 <br /> IN FILL SUMP (TYP.) 1 71 0 VAPOR RETURN PIPING (TYP.) <br /> ®®®®®®® 0 4" COAXIAL "UPP" REMOTE <br /> CAD WELD TO MAIN 0 134 <br /> GROUNDING WIRE. FILL PRODUCT PIPING (TYP.) <br /> 1 " 30 0 <br /> ROUTE TO GROUND ROD <br /> 80 0 1 TANK TOP (TYP.) <br /> JACK SCREW <br /> 0 <br /> 0 <br /> DROP TUBE W/ OVERFILL PREVENTION 15 SUMP QRpFESSlpyq� <br /> VALVE SET @ 95% CAPACITY. TERMINATE 31 SENSOR 27 4"x4"x3" EXTRACTOR TEE _�``� F4- <br /> DROP TUBE MIN. 4 , MAX. 6 ABOVE FITTING (TYP.) J HAL P71UBB <br /> STRIKER PLATE (TYP. SEE NOTE #5) <br /> NOTE: THE EQUIPMENT DEPICTED AND LISTED ABOVE IS G84 <br /> 1 /4" DRAIN/TEST BUSHING. IN ACCORDANCE WITH CARB EXECUTIVE ORDER VR-102 <br /> FACTORY INSTALLED FOR STAGE I ENHANCED VAPOR RECOVERY (EVR) �P <br /> ('B_ Fill Sump Installation Detail rb` <br /> NOT USED F NOT USED <br /> T5-1 SCALE: 1 "=1 '-0" T5-2 SCALE: NONE T5-2 SCALE: NONE 05/27/22 <br /> 0 <br /> S <br /> heet Notes <br /> U = Z j Z X <br /> N <br /> O <br /> 1 . — PIPE & CONDUIT PENETRATIONS: <br /> ALL PENETRATIONS OF THE TANK SUMPS SHALL BE SEALED WITH DOUBLE BULKHEAD FITTINGS SHALL BE INSTALLED PERPENDICULAR TO SUMP WALL TO ENSURE THE PROPER INSTALLATION OF ALL BULKHEAD FITTINGS AND RESULTANT WATER TIGHTNESS. ALL PIPING, 0 0 0 N <br /> CONDUIT AND GROUNDS THAT PENETRATE THE SUMP SIDE WALLS MUST BE SEALED IN SUMPS. SUMPS SHALL BE HYDROSTATICALLY TESTED WITH STANDING WATER FOR A PERIOD OF 24 HOURS TO INSURE THAT THE SUMPS ARE WATERTIGHT. m <br /> 2. — PIPING TESTING: <br /> C C Y j N <br /> TESTING OF THE SECONDARY CONTAINMENT PIPING IS REQUIRED. THE CONTAINMENT TERMINATION FITTING IN THE SUMP IS TO BE INSTALLED WITH THE VALVE TURNED DOWN. THE PIPING IS TO BE CONTINUOUSLY MONITORED BY VACUUM, PRESSURE OR 3 U a <br /> 0 o v a o <br /> HYDROSTATIC. THEREFORE THE VALVE UNLESS BEING TESTED SHOULD REMAIN CLOSED. <br /> 3. — SUMP SENSORS: <br /> SENSOR TO BE MOUNTED AT SIDE OF TANK WHERE VENT/VAPOR PIPING PENETRATES INTO THE SUMP IS MADE AND BELOW LOWEST PENETRATION FITTING WITHIN SUMP AREA. MOUNT SENSOR FLUSH C1 O <br /> TO LOWEST POINT IN SUMP BOTTOM. ALL TANK SUMP SENSORS SHALL BE NON—DISCRIMINATING AND POSITION SENSITIVE. N <br /> CD <br /> 4. — FILL AND VAPOR CAP HEIGHT TO GRADE: 115 2" BELL X MALE ADAPTER (TYP.) cli <br /> THIS DIMENSION IS CRITICAL AND MUST BE ADHERED TO. CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR WILL BE BACK CHARGED FOR EXPENSE TO CORRECT INCONSISTENCIES. Vf N <br /> 72 3" BONDED FITTING (TYP.) <br /> 5. — DROP TUBE CRITICAL DIMENSION: N Q) <br /> THIS DIMENSION IS CRITICAL AND MUST BE ADHERED TO. CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR WILL BE BACK CHARGED FOR EXPENSE TO CORRECT INCONSISTENCIES. 3/4" 3-WAY BALL VALVE 60 4) +-J m E <br /> 3" OVER 2" FRP ~ <br /> ADDITIVE PIPING (TYP.) Ln i 6 <br /> 6. — MANHOLE CROWNS: 10116 ,_ p <br /> ALL MANHOLE OPENINGS ON THE TANK SLAB SHALL BE INSTALLED WITH A 2" X 18" RUN CROWN OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE. — — m <br /> 7. — U.G. CONDUIT: 3/4" S.S. PIPING AND — — LJ.I C (V <br /> ALL U.G. CONDUIT TO TANK SUMPS SHALL BE ROBROY RIGID STEEL PVC COATED SCHEDULE 40 (NO SUBSTITUTIONS). CONDUIT MINIMUM BURY DEPTH IS 24" PER CODE. ALL JUNCTION BOXES SHALL FITTINGS M N <br /> BE CLASS 1 DIV. 2 RATED. ALL ELECTRICAL CONDUIT IN SUMPS SHALL INCLUDE A SEAL—OFF ENTERING AND LEAVING. SEAL—OFFS SHALL BE INSTALLED 6" MIN. ABOVE HIGHEST PENETRATION IN SUMP. 3/4" THREADED PLUG 2" X 3/4" BELL REDUCER •� Q 00 N o <br /> 8. — FILL & VAPOR RISER GROUNDING: cV o <br /> 3/4 X 15 FLEXIBLE m Q N O <br /> ALL FILL AND VAPOR RISERS SHALL BE GROUNDED TO PREVENT STATIC DISCHARGE. SEE DETAIL E ON SHEET E-4 FOR RISER GROUNDING DETAIL. 3/4" 3-WAY BALL VALVE 60 45 CONNECTOR N <br /> 9. — STAINLESS STEEL FITTINGS: <br /> 67 NEW 3/4" "Y" STRAINER L Ln cn <br /> o <br /> m o N U6 <br /> CONTRACTOR TO PROVIDE ALL MISCELLANEOUS NPT FITTINGS AND NIPPLES FOR CONNECTIONS TO TURBINES, SIPHON SYSTEM 2" X 3/4" S.S. DOUBLE in V rc-of Y <br /> AND VAPOR RECOVERY SYSTEM. ALL STAINLESS STEEL FITTINGS SHALL BE MANUFACTURED BY "STANDARD PIPE PRODUCTS" TAP BUSHING 53 j <br /> OR EQUAL SPECIFICATIONS AS FOLLOWS: <br /> DIMENSIONS MATERIAL THREAD PRESSURE RATING 2" NPT TANK BUNG Q <br /> S.S. FITTINGS FITTING w <br /> (TEES, ELBOWS) TANK TOP (TYP.) <br /> CD <br /> CLASS 150/PN 20 ASME B16.3 ASTM A- 182 ASME B. 1 20. 1 ASME B16.3 i <br /> S.S. UNIONS <br /> CLASS 150/PN 20 ASME B16.39 ASTM A- 182 ASME B. 1 20. 1 ASME B16.3 <br /> S.S. PIPE 3/4" S.S. PIPING STINGER TO WITHIN 6" 3/4" THREADED PLUG <br /> CLASS 150/PN 20 ASTM A733 ASTM A-312 ASME B. 1 20. 1 ASME B16.3 TO TANK BOTTOM (FIELD CUT TO LENGTH) Ln <br /> 0 <br /> O <br /> 10. - CORROSION PROOF: ( G' Gasoline Side Sum Section Detail For Additive Automation � Ncn <br /> ALL TURBINE PUMP HEADS TO HAVE ADVANCED CORROSION PROOF PROTECTION WITH E—COATED FINISH. T5-2 SCALE: 1 " — 1 '-0" z p <br /> � r <br /> a� <br /> i� <br />