Laserfiche WebLink
Environmental Health Department <br />Time In: <br />12:30 pm <br />12:00 pm <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (916) 952-6552 Owner/Operator: DRD HOSPITALITY INC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 179 COMMERCE AVE, MANTECA 95336 <br />Date: 06/01/2022Name of Facility: HOLIDAY INN EXPRESS HOTEL & SUITES <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #13 Cyanuric Acid Concentration <br />OBSERVATIONS: Cyanuric Acid is >100 ppm. Provide Cyanuric Acid 0ppm - 100 ppm by the end of the season. <br />CALCODE DESCRIPTION: Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Spa skimmer is lacking float valve. Provide float valve in 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: Difference between the Influent and Effluent measurement is higher than 10 PSI. Back wash filter today. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 45 <br />7.4 <br />3 <br />>100 <br /> 102.00 <br />Combined chlorine:ppm <br />NOTES <br />Spa inspection. <br />Influent 18 PSI <br />Effluent 3 PSI <br />GFCI and lights are working. <br />Emergency shut off switch is working. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0015048 PR0522086 SC001 06/01/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD