My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2506
>
3600 - Recreational Health Program
>
PR0360339
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2022 9:23:23 AM
Creation date
6/14/2022 9:18:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0360339
PE
3611
FACILITY_ID
FA0001794
FACILITY_NAME
IRON HORSE APARTMENTS
STREET_NUMBER
2506
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12304037
CURRENT_STATUS
01
SITE_LOCATION
2506 COUNTRY CLUB BLVD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Time In: <br />11:04 am <br />10:27 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 951-4391 Owner/Operator: PATMON COMPANY INC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2506 COUNTRY CLUB BLVD, STOCKTON 95204 <br />Date: 06/13/2022Name of Facility: IRON HORSE APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free chlorine is below 1 ppm. Adjust to 1 ppm to 10 ppm. This was corrected on site. Free chlorine after <br />correction was 6.4 ppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #37 Electrical Hazards MAJOR <br />OBSERVATIONS: The light inside the pool does not turn off when the ground fault circuit interrupter (GFI) is tested. Repair <br />GFI so that it is in good working order today. Close pool area until the corrections are made and verified by this department. <br />CALCODE DESCRIPTION: Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br />California Electrical Code. (CEC 680.4) Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br />fault circuit interrupter. (CBC 3160B) <br /> #4 Safety Equipment <br />OBSERVATIONS: Some of the wood between concrete slabs on the pool deck were observed missing or damaged. Fill <br />gaps with concrete or wood within 2 weeks. (REPEAT) <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: First step on the deep end is cracked and broken. Repair/replace within 2 weeks. (REPEAT) <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001794 PR0360339 SC001 06/13/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.