COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
111
>
3600 - Recreational Health Program
>
PR0360252
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/29/2022 11:22:33 AM
Creation date
6/14/2022 11:52:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0360252
PE
3612
FACILITY_ID
FA0001186
FACILITY_NAME
BEST WESTERN HERITAGE INN
STREET_NUMBER
111
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95207
APN
10213008
CURRENT_STATUS
01
SITE_LOCATION
111 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Time In: <br />12:50 pm <br />12:15 pm <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: Owner/Operator: ATHARWA INVESTMENTS LLC <br />Inspection Type: INSPECTION/REINSPECTION (Chargeable) <br />Address: 111 E MARCH LN, STOCKTON 95207 <br />Date: 06/23/2022Name of Facility: BEST WESTERN HERITAGE INN <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: The free chlorine was 2.2 ppm. Maintain free chlorine between 3.0-10.0 ppm at spa. Keep spa closed <br />until correction is verified by EHD. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #37 Electrical Hazards MAJOR <br />OBSERVATIONS: The GFCI for the pool and spa lights was not working properly, the switch shut off right after it was reset. <br />Keep pool and spa closed until GFCI and electrical for the pool and spa lights are fixed and working properly or, the <br />electricity to the pool and spa lights can be disconnected by an electrician and the service report is submitted to EHD. <br />Call EHD for re-inspection prior to re-opening pool and spa. <br />CALCODE DESCRIPTION: Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br />California Electrical Code. (CEC 680.4) Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br />fault circuit interrupter. (CBC 3160B) <br /> #4 Safety Equipment <br />OBSERVATIONS: Both life rings did not have rope available. Provide rope for both life rings, rope length must be maximum <br />width of pool and rope must be stored in a way that will prevent kinking or fouling. Correct today. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Spa skimmer did not have float assembly or o-ring. Provide float assembly and o-ring within 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001186 PR0360252 SC333 06/23/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.