My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0043020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JAHANT
>
5647
>
4300 - Water Well Program
>
WP0043020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2022 9:32:33 AM
Creation date
6/16/2022 9:09:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4300 - Water Well Program
RECORD_ID
WP0043020
PE
4378
STREET_NUMBER
5647
Direction
E
STREET_NAME
JAHANT
STREET_TYPE
RD
City
ACAMPO
Zip
95220-
APN
00519028
ENTERED_DATE
2/28/2022 12:00:00 AM
SITE_LOCATION
5647 E JAHANT RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 6, 2022 Lab ID : STK2235428 <br /> San Joaquin Co. Environmental Health Dep Customer : 3-17919 <br /> Quality Control- Inorganic <br /> Constituent Method Date/ID Type Units Cone. QC Data DQO Note <br /> Wet Chem <br /> Nitrate 300.0 (STK2235054-004) MSD mg/L 40.00 101% 85-119 <br /> MSRPD mg/L 10.00 7.9% <19 <br /> 300.0 04/20/22:205693njb CCB mg/l 0.00 0.5 <br /> CCV mg/l 20.00 98.1% 90-110 <br /> CCB mg/l 0.00 0.5 <br /> CCV mg/l 20.00 98.2% 90-110 <br /> Nitrate+Nitrite as N 300.0 04/20/22:204322NJB Blank mg/L ND I <0.1 <br /> Nitrate Nitrogen 300.0 04/20/22:204322NJB Blank mg/L ND <0.1 <br /> itrite 300.0 04/20/22:204322NJB Blank mg/L ND <0.5 <br /> LCS mg/L 15.00 99.5% 90-110 <br /> MS mg/L. 30.00 95.6% 74-126 <br /> (CC 228118 1-00 1) MSD mg/L 30.00 103% 74-126 <br /> MSRPD mg/L 10.00 7.6% :520 <br /> MS mg/L 30.00 93.9% 74-126 <br /> (STK2235054-004) MSD mg/L 30.00 102% 74-126 <br /> MSRPD m 10.00 8.1% 1 <20 <br /> 300.0 04/20/22:205693njb CCB mg/l 0.00 0.5 <br /> CCV mg/l 15.00 98.5% 90-110 <br /> CCB mg/l 0.00 0.5 <br /> CCV m 15.00 98.4% 90-110 <br /> Nitrite Nitrogen 300.0 04/20/22:204322NJB Blank mg/L ND <0.2 <br /> Sulfate 300.0 04/20/22:204322NJB Blank mg/L ND <0.5 <br /> LCS mg/L 50.00 101% 90-110 <br /> MS mg/L 100.0 92.7% 82-124 <br /> (CC 2281181-00 1) MSD mg/L 100.0 100% 82-124 <br /> MSRPD mg/L 10.00 6.7% :523 <br /> MS mg/L 100.0 91.5% 82-124 <br /> (STK2235054-004) MSD mg/L 100.0 99.4% 82-124 <br /> MSRPD mg/L 10.00 7.1% <23 <br /> 300.0 04/20/22:205693njb CCB mg/l 0.185 0.5 <br /> CCV mg/l 50.00 99.9% 90-110 <br /> CCB mg/l 0.196 0.5 <br /> CCV mg/l 50.00 99.6% 90-110 <br /> BAS 5540C 04/20/22:205848jba CCB mg/l 0.00 0.1 <br /> CCV mg/1 10.00 100% 99-101 <br /> BAs Screen 5540C MS mg/L 10.00100% 90-110 <br /> 100% 90-110 <br /> (SP 2206441-001) MSD mg/L 10.00 <br /> MSRPD m 10.00 0.0% _<0.1 <br /> Definition <br /> ICB :Initial Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> Ms :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> Dup :Duplicate Sample-A random sample with each batch is prepared and analyzed in duplicate.The relative percent difference is an <br /> indication of precision for the preparation and analysis. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> ND :Non-detect-Result was below the DQO listed for the analyte. <br /> DQO :Data Quality Objective-This is the criteria against which the quality control data is compared. <br /> Page 8 of 9 <br />